Brand: KITOZER Series: KTR-CAMTHERMAL Category: Camera / Thermal Camera
thermal 384×288visible 2MPtemp ±2 Cfire-point alarmKTR-CAMTHERMAL
Table of Contents
Toggle1. Overview
The KITOZER KTR-CAMTHERMAL is a dual-spectrum (thermal plus visible) network camera. An uncooled vanadium-oxide (VOx) infrared detector senses surface temperature distribution; it outputs both thermal and visible views with online temperature measurement, fire-point identification and temperature-anomaly alarms. A normal camera shows whether someone is present; a thermal camera shows where things are overheating. It is the core device for forest fire prevention, industrial temperature measurement, room overheating warning and electrical fire monitoring.
KTR-CAMTHERMAL thermal resolution 384×288 (108,800 pixels), field of view about 37.5 x 28.5 degrees (25 mm lens optional), temperature range -20 to +150 C (telephoto option up to +550 C), accuracy plus or minus 2 C or 2 percent of reading. Visible channel 2 MP (1080P) with 30 m IR. Supports ONVIF/RTSP/GB28181, integrates with Hikvision, Dahua, Uniview NVR or a self-built VMS. Built-in fire algorithm (over 60 C and over 2×2 pixels triggers alarm), people counting and area intrusion.
Typical uses: substation and switchgear cable-lug overheating; PV hot-spot detection; chemical plants and material yards; rooms and battery cabinets early overheating; tunnels and highways; forest fire lookout. KTR-CAMTHERMAL detects smoldering fires at 150 to 300 C, 5 to 10 minutes before a smoke detector, buying time for evacuation and suppression.
2. Key Features
Dual spectrum
- Thermal 384×288.
- Visible 2 MP.
- Picture-in-picture.
- Synchronized recording.
Online temp
- Range -20 to +150 C.
- Accuracy ±2 C or ±2%.
- Point/line/box measurement.
- Auto hottest-spot tracking.
Fire alarm
- Alarm over 60 C.
- Area over 2×2 pixels.
- Audible/visual and platform upload.
- GB28181 protocol.
Industrial rating
- IP67 waterproof.
- -40 to +60 C.
- 30 m IR.
- Bracket and sun shield.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-CAMTHERMAL |
| Thermal resolution | 384×288 (VOx uncooled) |
| Thermal lens | 15 mm (FOV 37.5×28.5 deg) |
| Temp range | -20 to +150 C |
| Accuracy | ±2 C or ±2% reading |
| Visible | 2 MP 1080P |
| IR illumination | 30 m |
| Video protocol | ONVIF/RTSP/GB28181 |
| Alarm | fire point / intrusion / tripwire |
| Power | DC12 V / PoE (optional) |
| Rating | IP67 |
| Operating temp | -40 to +60 C |
4. Reference Prices
KTR-CAMTHERMAL standard (15mm/384): Ref. USD 903~1361 / pc (CNY 6500~9800 at 7.2)
KTR-CAMTHERMAL tele (25mm/+550 C): Ref. USD 1361~2083 / pc (CNY 9800~15000 at 7.2)
KTR-CAMTHERMAL PTZ (dual-spectrum): Ref. USD 2083~3472 / pc (CNY 15000~25000 at 7.2)
PoE injector (48V/15W): Ref. USD 17~28 / pc (CNY 120~200 at 7.2)
Pole mount kit (3 m): Ref. USD 42~69 / set (CNY 300~500 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Substation cable-lug overheating.
- PV hot-spot detection.
- Chemical plants and material yards.
- Room and battery cabinet overheating.
- Tunnel and highway fire.
- Forest fire lookout.
6. Installation & Maintenance
Installation
- Choose lens by distance (15 mm near, 25 mm far).
- Mount 3 to 6 m high, downward 15 to 30 degrees.
- Avoid direct sunlight on the lens (thermal sensors hate sun).
- Avoid glass curtain walls (IR cannot penetrate glass).
- Power DC12 V or PoE.
- Network cable to NVR or VMS.
- Draw temperature ROI on the platform.
- Set thresholds (e.g., fire 60 C, cable lugs 70 C).
- Verify accuracy with a black body or heat source.
Maintenance
- Clean the thermal window monthly with lens paper (no alcohol).
- Calibrate against a black body quarterly.
- Check sun shield and bracket tightness.
- Inspect the outdoor gasket every six months (waterproof).
- Never point at the sun (ruins the detector).
- Check PoE connector oxidation.
7. FAQ
- Q:Thermal vs IR-illuminated camera?
A:IR-illuminated cameras light the scene with IR LEDs and show a gray visible image; they cannot measure temperature. Thermal cameras (KTR-CAMTHERMAL) receive infrared radiation emitted by the object itself (hotter objects radiate more) and form a temperature map. The principles are different: IR illumination is active lighting for viewing; thermal is passive sensing for temperature. - Q:Can thermal see through walls?
A:No. Infrared travels in straight lines like visible light and cannot penetrate walls, glass or thick objects. Thermal shows surface temperature: looking at a wall measures the wall surface (warmed by sun). It cannot see people or fires through walls. Thermal can see fire through smoke (smoke transmits IR better than visible), but not through walls. - Q:Is ±2 C accuracy enough?
A:For cable lugs (abnormal rise from 40 to 70 C, a 30 C anomaly) ±2 C is enough; the anomaly is far larger than the error. For body screening (36 to 38 C) ±2 C is not enough (it cannot separate 37 C from 38 C); use a medical forehead thermometer or a black-body-calibrated thermal camera at ±0.3 C. KTR-CAMTHERMAL is industrial at ±2 C and is not recommended for fever screening. - Q:Can thermal see people in the dark?
A:Yes, and this is its strength. Human skin is about 30 to 33 C, against a night ground at 10 C; thermal shows people clearly in total darkness with no illumination. This is core for security and rescue: an IR-illuminated camera goes dark beyond 50 m, while thermal detects a human heat source at 300 to 500 m.
8. Trend & Selection
Thermal detector resolution moves from 384×288 to 640×512 and 1280×1024, quadrupling pixels. AI upgrades from fire detection to transmission-line defect diagnosis (insulators, lugs, arresters). Thermal moves from industrial security to consumer-grade (phone thermal modules). Dual-spectrum fusion (thermal plus visible super-resolution alignment) is standard. Cloud remote temperature measurement, and inspection robots carry thermal cameras to replace handheld inspections.
9. Delivery & Service
KITOZER sizes KTR-CAMTHERMAL lens and bracket by distance and target, providing ROI setup and GB28181 integration notes. Delivery includes camera, bracket, power supply, manual and certificate. Warranty covers temperature calibration and algorithm updates.
10. Additional Notes
A common pitfall is mounting thermal behind glass. IR cannot pass glass; the camera sees the glass surface (cooled by indoor AC or sun-warmed outdoors), and cannot measure equipment behind it. Thermal must be outdoor or through an open aperture, never behind glass.
Another pitfall is pointing the lens at the sun. The sun’s 6000 K black-body IR radiation is intense; aiming at the sun for a few minutes ruins the detector irreversibly. Avoid sunrise/sunset directions and add a sun shield. For forest lookout, block or mask the sun-tracking positions.
Selection summary: dual spectrum, 384×288, range -20 to +150 C, ±2 C, IP67. The thermal camera is the early warning for temperature anomalies; the keys are no glass, no sun, ROI and thresholds set by target, and regular black-body calibration.
Additional tip: under summer sun, equipment surface itself is hot (cable jacket at 60 C), causing many false alarms. Exclude sunlit zones in the ROI, or set delta-temperature alarms (alarm only when temperature is 20 C above the historical average) instead of absolute thresholds. In winter, equipment is cold; lower thresholds accordingly.
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140