KITOZER
KITOZER

KITOZER Aspirating Smoke Detection System For Clean Room

The KITOZER aspirating smoke detection system for clean rooms provides continuous air sampling in environments where conventional point detectors would be disturbed by laminar airflow, high ceilings, or strict contamination controls. The system draws air through sampling pipes mounted above the ceiling void or below the raised floor, analyzing particles in a remote detector that sits outside the clean space. This design keeps sensitive optics away from the clean room and allows maintenance without gowning or process interruption.

Product Overview

The detector unit houses a high-efficiency aspirator, a forward light scatter optical chamber, and a particle filter. Sampling pipes are terminated in the clean room with minimal penetration, and air returns through a dedicated exhaust. The detector displays smoke level on an LCD and provides four alarm thresholds plus fault outputs. Ethernet or relay integration connects to the facility monitoring system.

Technical Specifications

Sensitivity is 0.005 to 20 percent obs per meter. Pipe network length up to 80 meters per detector. Number of sampling holes is up to 40. Airflow per hole is 20 to 40 liters per minute. Power is 24 volts DC. Operating temperature is 10 to 35 degrees Celsius. Enclosure is IP30. Relay outputs: four Form C. Filters are replaceable HEPA pre-filters.

Application Scenarios

Aspirating systems are used in semiconductor clean rooms, pharmaceutical manufacturing suites, food processing areas, data center under-floor and ceiling voids, museum galleries, and archival storage. They are also used in large atriums and warehouses with high ceilings where point detector spacing is impractical. The system is suitable for environments where contamination control or process uptime is paramount.

Advantages

Remote detector placement avoids contaminating the clean space. Sampling pipes reach above ceilings and under floors without installing detectors in process areas. Very early warning allows controlled shutdown of production before smoke damage. Multi-level alarms support staged response. Dust compensation and filter monitoring reduce false alarms. Maintenance can be performed outside the clean room.

Installation and Maintenance

Route sampling pipes in ceiling voids or raised floor plenums, with sampling holes positioned to sample representative air. Seal all pipe penetrations. Commission with a smoke test at each zone. Replace pre-filters every 6 months or when airflow drops. Calibrate the optical chamber annually. Inspect pipe network for leakage annually. Keep exhaust routed away from supply air intakes.

Engineering Notes

Seal all sampling pipe penetrations in the clean room ceiling. Route pipework in the plenum. Commission with a smoke test at each zone. Use HEPA pre-filters. Keep exhaust away from supply air intakes. Service the chamber outside the clean room to avoid contamination.

Code and Compliance

Aspirating systems must meet clean room fire detection standards. Submit the pipe layout and sensitivity settings for approval. Annual service includes filter replacement and chamber calibration. Keep filter change records. Do not open the detector inside the clean room without containment.

Warranty and Accessories

From $2,900 per aspirating detector. The detector carries a two-year warranty. KITOZER supports pipe routing, filter selection, and integration. Spare filters and pumps are available. Contact +86 13922289957 for clean room system design.

Detailed Application Examples

An aspirating detector samples a clean room through pipe runs in the ceiling plenum. HEPA pre-filters protect the chamber, and the detector is located outside the clean room for service. Sensitivity is set for very early warning. Filters are replaced every 6 months, and the chamber is calibrated annually.

Long-term Operational Benefits

The aspirating detector shares the low-maintenance profile of other aspirating systems, with filters and chamber cleaning as the only recurring tasks. Because it is located outside the clean room, service does not require gowning or process shutdown, saving labor. Very early warning allows controlled shutdown of production equipment, protecting high-value wafers or batches. The system integrates with the facility monitoring platform for remote alarm management.

System Integration

The aspirating detector relays map alarm levels to the clean room facility monitoring system. Warning triggers a production pause investigation; Fire 1 notifies the fire team; Fire 2 releases suppression. Because the detector is remote from the clean room, service does not require gowning. The system logs smoke concentration trends, which helps identify recurring hot spots before they become fires.

Price

From $2,900 per aspirating detector. Contact +86 13922289957 for clean room system design.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com