KITOZER
KITOZER

KITOZER IR3 Flame Detector For Hydrocarbon Fires

The KITOZER IR3 flame detector uses three infrared sensors at different wavelengths to recognize the characteristic flicker of hydrocarbon flames while rejecting false sources such as sunlight, hot machinery, and welding arcs. The triple IR algorithm analyzes radiation at 4.0, 4.3, and 4.5 micrometers, where flame emission from CO2 combustion is strongest, and confirms a fire only when all three channels match the expected pattern. This makes the detector suitable for outdoor and industrial settings where point detectors cannot see the flame.

Product Overview

The detector is housed in a weatherproof stainless steel or aluminum enclosure with a sapphire window and mounting bracket. It provides relay outputs for alarm and fault, plus 4 to 20 milliamp or Modbus options for integration. A local LED indicates status, and a test emitter allows functional checks without an open flame.

Technical Specifications

Spectral range is 4.0 to 4.5 micrometers. Field of view is 90 degrees conical. Response time is less than 5 seconds for a 0.1 square meter gasoline fire. Range is up to 25 meters. Operating voltage is 24 volts DC. Alarm relay is 2 amps Form C. Fault relay is 2 amps Form C. Enclosure is IP66. Operating temperature is -40 to 75 degrees Celsius. Intrinsically safe option available.

Application Scenarios

IR3 flame detectors are installed in oil and gas facilities, petrochemical plants, paint spray booths, aircraft hangars, fuel depots, turbine enclosures, and industrial process areas handling flammable liquids or gases. They are also used in tunnels, cable racks, and outdoor loading areas where smoke and heat detectors are ineffective. The detector sees through smoke and light steam, responding directly to the flame.

Advantages

Triple IR sensing minimizes false alarms from sunlight, heaters, and welding. The detector responds within seconds to flame, much faster than smoke or heat detectors. It works outdoors and in large open spaces. Weatherproof and intrinsically safe options suit hazardous areas. The sapphire window resists abrasion. Relay outputs integrate with any fire panel.

Installation and Maintenance

Mount the detector with a clear line of sight to the hazard, at a height and angle specified by design. Avoid aiming at reflective surfaces or direct sunlight. Route cable through the supplied gland. Test annually with a certified test emitter. Clean the window with a soft cloth and non-abrasive cleaner. Inspect wiring and enclosure seals every 6 months. Replace the detector if the window is scratched or the housing corroded.

Engineering Notes

Mount detectors with clear line of sight to the hazard. Avoid aiming at sunlight or reflective surfaces. Use the test emitter annually. Keep the window clean. Provide weatherproof cable glands. Intrinsically safe versions for hazardous areas.

Code and Compliance

Flame detectors must comply with local flame detector standards. Submit the detector layout and coverage plan for approval. Annual testing includes emitter tests. Keep a detector schedule on the as-built drawing. Replace the window if scratched.

Warranty and Accessories

From $480 per IR3 flame detector. The detector carries a two-year warranty. KITOZER supplies hazardous-area certified and weatherproof versions. Spare emitters and mounting brackets are available. Contact +86 13922289957 for hazardous-area certified versions.

Detailed Application Examples

Two IR3 flame detectors cover a pump house handling diesel fuel, with overlapping coverage. The triple IR algorithm rejects sunlight and welding. A test emitter confirms operation annually. The detectors are wired to the fire panel with alarm and fault relays. Windows are kept clean.

Long-term Operational Benefits

IR3 flame detectors have a long service life with no consumable parts beyond the window and electronics. Because they respond within seconds, they protect high-value process equipment from rapid flame spread. The triple IR algorithm minimizes false alarms, avoiding costly shutdowns. The weatherproof housing survives outdoor conditions for years. A two-year warranty covers electronics.

System Integration

Flame detectors wire to the fire panel with separate alarm and fault relays. Because they respond in seconds, they are often used as the primary detection in high-hazard areas where smoke detection is too slow. The 4 to 20 milliamp option provides continuous signal monitoring, so the panel can see sensor health. Multiple detectors in overlapping coverage improve reliability.

Why Choose KITOZER

KITOZER flame detectors are built for hazardous area duty and backed by factory support. Each detector is emitter-tested before shipment. KITOZER supplies mounting brackets, test emitters, and cable glands as a complete package, ensuring coverage as designed.

Summary

In summary, the IR3 flame detector provides rapid, low-false-alarm detection for hydrocarbon hazards. Its triple IR algorithm and weatherproof housing suit outdoor and industrial use. KITOZER supplies the detector with a two-year warranty and supports hazardous-area certified versions.

KITOZER supports project quantities and hazardous-area certified versions for industrial sites.

Price

From $480 per IR3 flame detector. Contact +86 13922289957 for hazardous-area certified versions.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart