Table of Contents
ToggleProduct Overview
The KITOZER differential pressure transmitter measures small pressure differences between two spaces, such as clean room and corridor, filter inlet and outlet, or duct and room. The 0 to 10 kPa range is optimized for HVAC and filtration monitoring where differential pressures are low but accuracy matters. The dual pressure ports accept flexible tubing, and the 4 to 20 mA or Modbus output feeds the building automation system. A selectable bidirectional range allows monitoring of both positive and negative room pressurization, and an optional LCD shows the live differential on the device itself.
Technical Specifications
Range 0 to 10 kPa bidirectional, overpressure 5x. Accuracy +/-0.5% FS, option +/-0.25%. Output 4 to 20 mA, 0 to 10 V, or Modbus RS485. Power 12 to 30 VDC. Wetted parts ABS and silicone. Ports 6 mm barbed for tubing. Mounting wall or DIN rail, IP54. Operating temperature 0 to 50 C. CE, KITOZER, 3 year warranty.
Applications
This transmitter is the standard choice for pharmaceutical clean rooms, hospital operating theatres, electronics assembly workshops, and laboratory fume hood monitoring. It also tracks filter loading in HVAC bag filters and HEPA filters, triggering replacement when the differential pressure exceeds the alarm setpoint. In dust collection systems, the transmitter signals when cartridge filters need cleaning or replacement. In paint booths, it maintains the correct booth-to-room pressure relationship to prevent overspray from migrating into adjacent areas.
Advantages
The low differential range and bidirectional sensing allow a single device to monitor both positive pressurization in clean rooms and negative pressurization in containment suites, simplifying spare parts. The plastic wetted parts avoid condensation issues that plague metal diaphragm sensors in humid duct applications. The optional Modbus output allows the BAS to read the sensor without additional analog input cards, and the local LCD gives maintenance staff immediate confirmation of room pressure without a tablet. The device is field-configurable via push buttons, so range and damping can be adjusted without software.
Installation and Maintenance
Mount the transmitter near the measured spaces, using the shortest possible tubing runs to minimize response delay. Connect the high side to the higher pressure reference and the low side to the lower pressure side, and avoid kinks in the tubing. Use a condensation trap if the tubing may collect water. During commissioning, zero the transmitter with both ports open to atmosphere. Check tubing connections quarterly for cracks or discoloration, and recalibrate annually against a digital manometer. In clean rooms, keep the transmitter behind a service panel so the housing finish does not compromise the cleanable wall surface.
Working Principle
The sensor is a capacitive or piezoresistive cell exposed to the two pressure ports through isolating diaphragms and fill fluid. The difference between the high side and low side pressure deflects the sensing diaphragm, and the resulting capacitance or resistance change is measured by an ASIC. The microcontroller linearizes the signal, compensates for ambient temperature, and drives a 4 to 20 mA or Modbus output scaled to the selected range. Because the cell measures only the difference between the two ports, atmospheric pressure changes cancel out automatically, which is essential when comparing a room to a corridor where both experience the same weather.
Selection Guide
Choose the 0 to 10 kPa range for clean room and HEPA filter monitoring. For higher duct static pressure, select the 0 to 5 kPa or 0 to 50 kPa range. For bidirectional room pressurization, choose the +/- 5 kPa version. For wet and dirty ducts, select the version with barbed ports and a condensate trap. For BMS integration, choose the Modbus output to avoid analog input cards. Order the LCD version if technicians need local confirmation during commissioning.
Each transmitter ships with a quick-start guide, two meters of tubing, and a mounting bracket. Optional accessories include a manifold valve, a condensation trap, a calibration hand pump, and a tubing cutter. KITOZER provides pre-configured units for common clean room setpoints such as +15 Pa and -50 Pa, which arrive ready to install. Spare transmitters are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom ranges or special output signals can be ordered with a short lead time. Every KITOZER transmitter is factory calibrated against traceable standards before shipment, and a calibration certificate is included with each unit. The devices undergo temperature cycle, EMC immunity, and IP rating testing during production. The installation manual includes wiring diagrams for common PLC analog input cards, and engineers can request a loop check sheet for commissioning. NIST-traceable calibration is available on request for regulated industries such as pharmaceutical and semiconductor clean rooms.