KITOZER
KITOZER

KITOZER UV Flame Detector For Fast Flaming Fires

The KITOZER UV flame detector senses ultraviolet radiation emitted by flames in the 180 to 260 nanometer band. Because UV radiation from flame travels quickly and is not blocked by smoke or dust, the detector responds in milliseconds to open fires, including hydrogen, metal, and other non-hydrocarbon flames that IR detectors may miss. It is widely used in industrial and aircraft hangar applications where rapid response is essential.

Product Overview

The detector houses a UV sensor tube, a timing circuit that requires the UV signal to persist for a set confirmation period, and relay outputs. The confirmation delay rejects brief UV sources such as lightning or arc welding. The weatherproof enclosure and mounting bracket allow wall or ceiling installation, and a test emitter checks function without a real flame.

Technical Specifications

Spectral range is 180 to 260 nanometers. Field of view is up to 120 degrees. Response time is less than 1 second. Range is up to 20 meters. Operating voltage is 24 volts DC. Alarm relay is 2 amps Form C. Fault relay is 2 amps. Enclosure is IP66. Operating temperature is -40 to 70 degrees Celsius. Confirmation delay is adjustable from 1 to 10 seconds.

Application Scenarios

UV flame detectors are used in aircraft hangars, rocket engine test stands, hydrogen storage areas, magnesium or aluminum powder processing, paint spray booths, and industrial ovens. They are also used as backup detection in turbine enclosures and on offshore platforms. The detector is effective on flames that emit little IR, such as hydrogen and metal fires.

Advantages

UV sensing responds within milliseconds to open flame. It sees through smoke and dust. It detects non-hydrocarbon flames that IR detectors miss. The confirmation delay rejects transient UV sources. Weatherproof construction suits outdoor use. Relay outputs are simple to integrate. The detector is compact and low-cost compared with multi-spectrum units.

Installation and Maintenance

Mount with a clear view of the hazard, avoiding direct sunlight and artificial UV sources. Route cable through the gland. Test annually with a certified UV test lamp. Keep the UV window clean; dust and oil block UV transmission. Inspect seals and housing every 6 months. Replace the UV sensor tube every 5 years per manufacturer guidance.

Engineering Notes

Mount UV detectors with clear line of sight. Avoid direct sunlight and artificial UV sources. Use the UV test lamp annually. Keep the window clean. Adjust confirmation delay to reject welding. Use in combination with IR for best false alarm rejection.

Code and Compliance

UV detectors must comply with local flame detector standards. Submit the detector layout for approval. Annual testing includes UV lamp tests. Keep a detector schedule. Replace the UV sensor tube at rated life.

Warranty and Accessories

From $420 per UV flame detector. The detector carries a two-year warranty. KITOZER supplies UVIR combination versions. Spare test lamps and windows are available. Contact +86 13922289957 for multi-spectrum UVIR combinations.

Detailed Application Examples

Two UV flame detectors cover a hydrogen battery room, where IR sensors would be less effective. The UV tube responds within 1 second, and a 2 second confirmation delay rejects lightning. A UV test lamp confirms operation annually. The UV sensor tube is replaced every 5 years.

Long-term Operational Benefits

UV flame detectors are simple and robust, with no moving parts. The UV sensor tube has a defined replacement interval, making maintenance predictable. Because they respond in under a second, they protect equipment where fast flaming fires develop. The confirmation delay rejects nuisance sources. The weatherproof housing suits outdoor installation. A two-year warranty covers the sensor.

System Integration

UV flame detectors wire to the fire panel with alarm and fault relays. Because UV is not blocked by smoke, they provide detection in early flaming stages when smoke detectors have not yet responded. The confirmation delay rejects transient UV sources. The detector can be used alone or paired with an IR detector for cross-verification, reducing false alarms.

Why Choose KITOZER

KITOZER UV flame detectors are built for fast flaming fire protection. Each detector is UV-tested before shipment. KITOZER supplies test lamps, windows, and mounting brackets as a complete package, ensuring reliable operation over the service life.

Summary

In summary, the UV flame detector provides milliseconds-fast detection for fast flaming and non-hydrocarbon fires. Its confirmation delay and weatherproof housing suit industrial use. KITOZER supplies the detector with a two-year warranty and supports UVIR combination versions.

KITOZER supports UVIR combination versions and project quantities for industrial sites.

Each unit is backed by local technical support and a global spares network.

For maximum false alarm rejection, pair the UV detector with an IR unit.

Spare UV sensor tubes and test lamps are held in stock for fast replacement.

Price

From $420 per UV flame detector. Contact +86 13922289957 for multi-spectrum UVIR combinations.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart