The KITOZER 90 degree horizontal cable tray elbow is a factory-made bend that changes the direction of a cable tray run by 90 degrees in the horizontal plane. The elbow is formed from the same material and finish as the straight tray, so the transition is smooth and continuous. The bend radius is designed to protect power and data cables during pulls, and pre-punched holes on the straight ends allow bolted splice joints. Using a factory elbow instead of a field-cut miter ensures consistent geometry, reduces installation time, and maintains the structural rating of the tray system.
Technical Specifications
Angle: 90 degrees horizontal. Width: available 100 mm to 600 mm. Material: galvanized steel, aluminum, or stainless steel. Sheet thickness: matches straight tray. Bend radius: 300 mm standard, larger radius for fiber optic runs. Standard finish: pre-galvanized, hot dip galvanized, or anodized aluminum. Fittings included: splice plates and bolts. Standards: IEC 61537, NEMA VE-1. Brand: KITOZER. Warranty: 10 years indoor, 15 years HDG outdoor.
Application Scenarios
90 degree elbows are used wherever a tray run must change direction around a column, wall, or piece of equipment. They are standard in data center overhead routing, industrial plant cable corridors, commercial building ceiling distribution, and outdoor cable trenches. Horizontal elbows are typically used at intersections, at wall penetrations, and at transitions between rooms. A large-radius elbow is specified for fiber optic backbones to avoid exceeding the minimum bend radius of the cable.
Advantages and Benefits
Factory elbows eliminate the guesswork and labor of field-cut miters. The smooth interior prevents jacket abrasion during cable pulls. Pre-punched ends speed installation, because the installer simply bolts the elbow between two straight sections. Matching material and finish ensure the tray looks like a continuous system. The bend radius is engineered for the cable type, reducing the risk of fiber microbends or power cable insulation damage. Because the elbow is load-rated, supports can be placed according to standard details without structural engineering review.
Installation and Maintenance Recommendations
Place a support within 300 mm of the elbow on both ends. Use two splice plates per joint, one on each side, and torque bolts to the recommended value. Bond the elbow to the grounding system. When pulling cables, use a pulling eye and lubricant, and never exceed the cable tensile rating. Keep the bend radius at or above the cable manufacturer minimum. After installation, inspect the elbow for sharp edges and touch up any cut edges with zinc paint. Do not modify the bend radius on site, because this can invalidate the load rating.
Every unit leaves the factory after a 100 percent function test, including a full load test at rated current, insulation resistance check, and communication port verification. Each chassis is visually inspected for finish quality and label legibility. A serial number plate records the production date, test result, and calibration reference, so the unit can be traced throughout its service life. KITOZER maintains a factory stock of common units and fittings for short lead-time orders, and larger projects are scheduled against a confirmed production plan. Standard export packing uses a double-wall carton with foam corners, and pallet packing is available for sea freight. The product is designed for disassembly and recycling at end of life, with clearly marked material types on the chassis.
Technical support is available by email and during business hours in the China time zone, with response within one working day. Installation guides, datasheets, CAD drawings, and declaration of conformity are provided on request for every order. KITOZER can also supply customized variants, including different outlet layouts, longer input cords, special colors, or OEM branding, subject to a minimum order quantity. The product family is designed to be compatible with accessories and mounting hardware from the same KITOZER range, so a single supplier can deliver the complete cable management or power distribution system for a project. After installation, KITOZER recommends keeping a small stock of spare parts on site, such as connectors, fuses, and mounting brackets, so routine repairs do not require long lead times.
KITOZER treats every order as a partnership rather than a single transaction. The sales engineering team works with the customer during design to confirm ratings, mounting options, and routing, so the delivered product matches the site conditions. During production, regular photo updates keep the buyer informed, and the finished goods are packed and labeled according to the project shipping mark. Documentation included with each shipment contains the packing list, test report, and certificate of conformity. For export orders, KITOZER handles export packing, container loading, and coordination with the forwarder, and can provide the required commercial invoice and packing list for customs clearance. After delivery, the local distributor or the factory itself provides commissioning guidance by video call, and remains available for technical questions during the first year of operation. This end-to-end support is why customers return to KITOZER for repeat projects across different sites and regions.
Price
From $18 per piece for a 300mm wide galvanized 90 degree elbow. Contact KITOZER for 45 degree elbows, vertical risers, and custom radii.