Table of Contents
ToggleProduct Overview
The KITOZER flow transmitter combines a turbine or paddle wheel sensor with a transmitter housing that outputs both a 4 to 20 mA flow signal and a pulse count for totalization. The device is designed for clean water, light oils, and other low-viscosity liquids in process skids, irrigation systems, and coolant loops. The compact insertion or inline version fits pipes from DN15 to DN200, and the local indicator shows instantaneous flow and accumulated volume without requiring a PLC connection. The 4 to 20 mA signal feeds flow control loops that throttle control valves or variable speed pumps.
Technical Specifications
Pipe size DN15 to DN200 inline or insertion. Accuracy +/-1% of reading, +/-0.5% optional. Output 4 to 20 mA isolated plus open collector pulse. Power 12 to 24 VDC. Wetted parts brass or 316L, FKM seal. Fluid temperature -20 to 120 C. Pressure rating PN16. Protection IP65. Display 6 digit LCD. CE, KITOZER, 3 year warranty.
Applications
This flow transmitter is used in water distribution skids, cooling water loops on machine tools, chemical dosing systems, reverse osmosis feed lines, and truck loading bays. In clean-in-place systems, the pulse totalizer records each rinse cycle volume for the batch report. In irrigation, the transmitter measures field water use and triggers the next zone when the programmed volume is reached. In building automation, it tracks domestic water consumption and compares against the bill to detect leaks. The brass inline version suits potable water applications, while the 316L version handles chemical additives.
Advantages
The combined analog and pulse output means one device provides both live flow control and totalized volume, eliminating a separate meter. The LCD allows local reading and configuration without a laptop, and the pulse output can drive a remote counter or a building automation pulse input. The turbine sensor has low pressure drop, so it does not waste pump energy, and it works with low-viscosity liquids without recalibration. The compact installation length fits in tight machine frames where bulkier magnetic meters would not fit.
Installation and Maintenance
Install the sensor with at least 5 upstream and 2 downstream straight pipe diameters to stabilize the flow profile. Mount the transmitter horizontally for air-free operation in liquid lines, and avoid locations where gas pockets can form. Use strainers upstream to protect the turbine from debris that could jam the rotor. Periodically remove the rotor and inspect for wear or trapped particles, and flush the line if readings drift. Calibrate against a known volume prover annually, and record the K-factor with the site documentation so any future swap uses the correct scaling.
Working Principle
The flowing liquid strikes a turbine rotor, causing it to rotate at a speed proportional to the average flow velocity. A pick-up coil or Hall sensor counts the rotor blades and produces a pulse frequency that scales with volumetric flow. The transmitter electronics convert the pulse frequency to a 4 to 20 mA signal for live flow control, and also output open-collector pulses for totalization. The K-factor, pulses per liter, is calibrated at the factory and stored in non-volatile memory. The LCD simultaneously displays instantaneous flow and accumulated volume, and a low-flow cut-off suppresses noise pulses below the turn-down threshold.
Selection Guide
Choose the inline version for permanent pipe installation, and the insertion version for large pipes where an inline meter would be expensive. For potable water, select the brass body with EPDM seal. For chemicals, select the 316L body with FKM seal. For high temperature oil, select the high temperature version. If batching is required, choose the pulse output version that can drive a batch controller. For slurries or dirty water, a turbine meter is not suitable; use an electromagnetic flowmeter instead.
Each meter ships with a quick-start guide, a calibration sheet with K-factor, and mounting gaskets. Optional accessories include a strainer, a pulsation damper, a batch controller, and a handheld calibrator. KITOZER provides pre-configured units for common pipe sizes and flow ranges, which arrive ready to install. Spare rotors and seal kits are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom pipe sizes or special K-factors can be ordered with a short lead time. Every KITOZER meter is factory calibrated against traceable standards before shipment, and a calibration sheet with K-factor is included. The installation manual includes wiring diagrams for common PLC and batch controller inputs, and NIST-traceable calibration is available on request. The meter is compatible with common batch controllers and energy management systems, and the Modbus option allows direct integration into SCADA without additional analog cards.
Price
From $125/pc. Contact +86 13922289957 for flow transmitter quotation and pipe size options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com