KITOZER Cabinet Monitor: 24 Loop Power Distribution Monitoring Device

Product Overview

The KITOZER 24 loop power distribution monitoring device is a DIN-rail mounted multi-channel measurement unit designed to bring real-time electrical visibility to low-voltage distribution cabinets in data centers, commercial buildings, and industrial plants. Instead of retrofitting 24 separate power meters, the KITOZER device samples 24 outgoing feeders through clamp-on current transformers and a shared voltage input, and it reports per-loop current, voltage, active power, reactive power, power factor, energy, and alarm state over Modbus. A built-in LCD shows the top few loops and the overall bus status, while the web or Modbus interface gives operators a complete per-feeder energy map. The unit also monitors busbar temperature, ambient temperature and humidity, and provides digital inputs for door contact and smoke detector status, making it a compact edge node for both electrical and environmental monitoring.

Technical Specifications

Measurement channels: 24 current loops via external CTs, 3 phase voltage shared input, optional 12 temperature inputs for busbar, 2 temperature plus humidity sensors. Accuracy: current class 0.5, voltage class 0.5, energy class 1. CT input: 5A or 1A secondary, primary configurable 5A to 6300A. Measurements per loop: current, voltage, active power, reactive power, power factor, frequency, energy import and export. Alarm: over current, under current, temperature high, door open, smoke, with programmable thresholds. Display: 2.4 inch color LCD, push buttons. Communication: dual Ethernet Modbus TCP, RS485 Modbus RTU, optional SNMP, Web HMI. Digital IO: 8 digital inputs, 4 relay outputs. Power supply: 85 to 265VAC. Mounting: DIN rail, operating -10 to 55 degrees C. Standards: CE, 5 year warranty.

Application Scenarios

The 24 loop monitor is typically installed in low-voltage main distribution boards, UPS output cabinets, column-level power distribution units in data centers, and industrial MCC panels where operators need per-feeder loading without paying for 24 separate meters. It is used to detect current imbalance on three phase feeders, to identify underloaded or overloaded circuits for right-sizing, to attribute energy consumption to tenants or departments, and to trigger alarms on busbar overheating. In data centers, it feeds the DCIM platform with per-PDU current, enabling capacity planning and hot spot detection. In commercial buildings, it supports tenant sub-metering for billing. In industrial plants, it feeds SCADA with per-line loading for process optimization.

Key Advantages

The primary advantage is cost per measurement point. A single DIN-rail unit replaces 24 standalone meters, cutting hardware cost, panel wiring, and commissioning time. Clamp-on CTs allow retrofit without de-energizing feeders, which is essential for live data center cabinets. Shared voltage input reduces wiring. The unit combines electrical, temperature, humidity, and digital inputs in one node, reducing the number of protocols to integrate. Modbus TCP and SNMP integrate directly into DCIM, BMS, and SCADA. The LCD gives local visibility when the network is down. Programmable thresholds and relay outputs enable local alarming and control without a master system. The 5 year warranty and DIN rail mounting simplify spares and replacement.

Installation and Maintenance Recommendations

Mount on DIN rail near the incoming voltage, install CTs on each outgoing feeder with correct polarity, and route CT secondary wires safely because they must never be open-circuited under load. Configure CT ratio per feeder in the controller, set voltage ratio, and set alarm thresholds after a few days of baseline data. On commissioning, compare loop current readings with a clamp meter on a few feeders to verify calibration. Maintenance is simple: verify CT torque annually, read the alarm log, and trend per-loop energy to identify drift. Because the unit is an edge node, back up its configuration file so replacement is fast. For data center deployments, integrate into DCIM and set up capacity alerts at 80 percent of feeder rating.

The 24 loop monitor is a cost effective replacement for a bank of standalone per-feeder meters, because the shared voltage input and clamp-on CTs reduce both hardware cost and panel wiring. It is commonly retrofitted into existing data center PDU cabinets without de-energizing feeders, and the per-loop energy data feeds directly into DCIM capacity planning. Operators use it to identify overloaded circuits for rebalancing and underloaded circuits for consolidation.

Ordering Information

The 24 loop monitor is supplied as a DIN rail master unit, with CTs, temperature sensors, and digital IO modules ordered separately to match the cabinet. The standard configuration includes dual Ethernet Modbus TCP, RS485, and a 2.4 inch LCD. Optional packages include SNMP, a Web HMI license, and a BACnet IP card for BMS integration. Clamp-on CTs are available from 5A to 6300A primary in split-core design for live retrofit. The master can be expanded with slave units up to 96 loops per site. Lead time is two to three weeks. KITOZER provides a register list, a cabinet drawing template, and commissioning guidance. The five year warranty covers the master unit.

Price

From $680 per piece excluding CTs. Contact the factory for CT selection, cabinet layout, and SNMP integration. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com