Table of Contents
ToggleProduct Overview
The KITOZER 42U server cabinet is a floor-standing 19-inch enclosure designed to house standard rack servers, storage arrays, network switches, and blade chassis in enterprise data rooms, small data centers, and branch server closets. With a clear width of 600 mm and a usable depth of 1000 mm, the cabinet provides enough bay depth for today generation of 2-way and 4-way rack servers while leaving room for rear cable management. The welded frame is built from heavy-gauge cold-rolled steel, delivering a static load rating of up to 1000 kg so that fully loaded equipment banks remain stable over years of operation. Front and rear perforated doors support high airflow, and removable side panels allow fast access during installation and servicing.
Technical Specifications
Unit height 42U, outer dimensions 2055 x 600 x 1000 mm (H x W x D), usable internal width 19-inch EIA standard, adjustable mounting rails at both front and rear positions, rail thickness 2.0 mm zinc-plated steel. Door perforation area 70 percent on front and rear doors, supporting natural convection and forced hot-aisle containment. Static load capacity 1000 kg, dynamic load 600 kg. Degree of protection IP20 as standard. Color options include matte RAL 7035 light gray and RAL 9005 black. The cabinet ships with four leveling feet and two pairs of heavy-duty casters (two braked), a full set of M6 cage nuts and screws, a vertical cable manager on each side, two 1U brush cable entry strips on the top cover, and a removable rear fan tray that accepts up to four 120 mm fans. Power options include a 1U horizontal PDU bracket and a vertical zero-U PDU mount. Operating temperature range 5 to 45 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Certification CE and RoHS.
Application Scenarios
This 42U cabinet is widely deployed in enterprise server rooms, campus data centers, hospital IT departments, bank branch equipment rooms, university computer labs, and industrial control rooms. It fits rack-mounted servers from 1U pizza boxes to 4U storage servers, core and aggregation switches, firewalls, UPS modules, and KVM consoles. The 1000 mm depth is especially well suited for enterprises running 2-way rack servers with full-width power supplies and rear cable arms, while the 600 mm width keeps the aisle footprint compact in raised-floor rooms with limited space. It also works as a single-cabinet pod in edge computing sites, retail back-office closets, and distributed branch offices where a full micro-module is not justified.
Key Advantages
The welded frame provides better structural rigidity than knock-down alternatives, reducing wobble when sliding heavy servers on extendable rails. The 70 percent perforation ratio matches the airflow output of high-density server fans, helping to eliminate hot spots without requiring immediate retrofitting of fan trays. Both front and rear doors lock with a same-key set, and side panels are lockable for physical security. The adjustable front and rear rails accept deep chassis without drilling. Cable management is built in, with vertical finger ducts and horizontal ring managers, so technicians can dress power and data cables separately. The cabinet is fully compatible with third-party shelves, rails, PDUs, and cooling units because it follows the universal 19-inch EIA mounting standard.
Installation and Maintenance Recommendations
Plan the cabinet layout before racking equipment: place heavy devices such as UPS and storage at the bottom, switches and patch panels at mid-height, and lighter blade servers near the top. Use extendable ball-bearing rails for servers heavier than 25 kg, and always secure the rear rail to prevent tipping. Load servers and switches from the bottom upward to keep the center of gravity low. When routing power cords, use the vertical zero-U duct on one side and the data cable manager on the other, separating the two bundles to reduce electromagnetic interference. Check fan tray filters quarterly and vacuum them if dust accumulates. Inspect cage nuts every six months and tighten any loose mounting screws. Keep the front and rear aisles clear by at least 1200 mm for hot and cold aisle separation, and do not block the top and bottom ventilation openings with cable bundles.
Price
From $680/pc, including leveling feet, casters, cage nut kit, and standard side panels. Contact +86 13922289957 for factory lead time, bulk discount, and customization options such as glass doors, black finish, or integrated PDU.