KITOZER
KITOZER

KITOZER Fire Emergency Broadcast Speaker 6W

The KITOZER fire emergency broadcast speaker 6W delivers intelligible voice evacuation messages and background music in commercial buildings, hotels, offices, and industrial facilities. The speaker is matched to a certified fire alarm voice control panel and provides fire-rated audio output that overrides normal paging. Its compact design and high sensitivity make it suitable for ceiling mounting in corridors, lobbies, and open-plan offices.

Product Overview

The speaker is a ceiling or wall unit with a 6 watt transformer tap, a metal or plastic grille, and a fire-rated cable connection. It is impedance-matched to the 100 volt or 70 volt line from the emergency amplifier. The unit includes a baffle box option for ceiling cavities and is available in white or off-white to match interior decor.

Technical Specifications

Rated power is 6 watts, with taps at 1.5, 3, and 6 watts. Sound pressure level is 90 decibels at 1 watt per meter. Frequency response is 150 to 15,000 hertz. Input line is 100 volts or 70 volts. Impedance is matched via transformer. Enclosure is white ABS with metal grille. Mounting is ceiling tile or wall. Weight is approximately 500 grams.

Application Scenarios

Emergency broadcast speakers are installed in every occupied area of commercial buildings, hotels, hospitals, schools, shopping malls, and industrial plants. They deliver recorded evacuation messages during fire alarm and allow live paging by security staff. In high-noise industrial areas, higher-power wall speakers are used; in offices, ceiling speakers provide even coverage.

Advantages

Voice evacuation is more effective than tones alone, allowing occupants to understand the emergency and route. The 100 volt line allows many speakers on one circuit with minimal loss. The transformer taps allow tuning coverage per zone. Compact ceiling design blends with interiors. Fire-rated cable connections meet code. Wide frequency response ensures intelligible speech.

Installation and Maintenance

Mount speakers at code-specified spacing, typically one per 60 to 100 square meters. Tap the transformer to the correct power for the ceiling height. Use fire-rated cable between the amplifier and speakers. After installation, perform a speech intelligibility test in the worst-case listening position. Inspect speakers annually for loose grilles and buzzing. Test the emergency amplifier monthly. Replace damaged speakers promptly.

Engineering Notes

Space speakers per coverage design. Tap the transformer for the correct power. Use fire-rated cable. Test speech intelligibility in the worst listening position. Keep grilles clean. Use horn speakers in noisy areas.

Code and Compliance

Speakers must comply with local emergency voice standards. Submit the speaker layout and power taps for approval. Annual testing includes voice intelligibility checks. Keep a speaker schedule on the as-built drawing. Replace buzzing speakers.

Warranty and Accessories

From $65 per 6W ceiling speaker. The speaker carries a two-year warranty. KITOZER supplies ceiling, wall, and horn versions in various powers. Spare transformers and grilles are available. Contact +86 13922289957 for horn and wall speaker options.

Detailed Application Examples

Twenty ceiling speakers cover a 1000 square meter office floor, tapped at 3 watts each. Speech intelligibility is verified in the worst listening position during commissioning. The emergency amplifier overrides background music during alarm. Speakers are tested monthly by the security operator.

Long-term Operational Benefits

Ceiling speakers have no moving parts and no consumables, giving a very long service life. Because they are standardized 100V units, replacement speakers are cheap and widely available. The transformer taps allow coverage tuning without rewiring. Speech evacuation is more effective than tones alone, improving occupant safety. A two-year warranty covers the speaker.

System Integration

Emergency speakers are wired on a 100V line from the emergency amplifier, which overrides background music during alarm. The amplifier has its own battery backup and monitors each speaker circuit for open or short circuits. Multiple zones allow evacuation messages to be directed only to the affected area. The system integrates with the fire alarm panel so a smoke alarm automatically triggers the voice evacuation message.

Why Choose KITOZER

KITOZER emergency speakers are built for voice evacuation duty and backed by a two-year warranty. Each speaker is audio-tested before shipment. KITOZER supplies matching transformers, grilles, and horn versions as a complete package, ensuring intelligible voice coverage.

Summary

In summary, the emergency broadcast speaker delivers intelligible voice evacuation in commercial buildings. Its 100V line and transformer taps allow flexible coverage. KITOZER supplies the speaker with a two-year warranty and supports ceiling, wall, and horn versions.

KITOZER supports project quantities and multi-zone amplifier packages for commercial buildings.

Each unit is backed by local technical support and a global spares network.

For high-noise areas, KITOZER offers 15 watt horn speakers.

Spare transformers and grilles are held in stock for fast replacement.

Contact KITOZER for project quantities and multi-zone amplifier packages.

Price

From $65 per 6W ceiling speaker. Contact +86 13922289957 for horn and wall speaker options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com