Table of Contents
ToggleProduct Overview
The KITOZER clamp-on ultrasonic flowmeter measures liquid flow without cutting the pipe, by mounting two transducers on the outside of the pipe wall. The transducers exchange ultrasonic signals upstream and downstream, and the time difference is converted into volumetric flow. This non-invasive installation makes the meter ideal for retrofit projects, temporary flow surveys, and corrosive or hygienic lines where opening the pipe is not allowed. The converter outputs 4 to 20 mA, pulse, and Modbus, and logs data to an internal memory for later download. A portable version with a rechargeable battery is available for service teams.
Technical Specifications
Pipe size DN50 to DN300 standard transducers, up to DN1000 optional. Accuracy +/-1% of reading. Liquid must be clean water, low sediment, air bubble content low. Temperature -40 to 160 C. Pipe material metal or rigid plastic. Outputs 4 to 20 mA, pulse, Modbus RS485. Power 85 to 265 VAC. Protection IP65. LCD display. CE, KITOZER, 3 year warranty.
Applications
Clamp-on ultrasonic meters are used for HVAC chilled water balancing, energy billing on existing pipes without isolation, leak detection in water distribution, and temporary measurement on production lines during commissioning. In building management, the meter records thermal energy by pairing with a temperature pair to calculate kWh. In oil and gas, it measures product lines where the fluid is too expensive or hazardous to drain. In agriculture, it monitors main irrigation flow without interrupting water delivery. The portable version is carried by service engineers to audit multiple sites in one trip.
Advantages
Because the transducers sit outside the pipe, there is no process interruption during installation, no leak path, and no wetted parts to corrode. The meter can be moved from one pipe to another during audits, which spreads the capital cost across many tasks. It has no pressure loss and no moving parts, so maintenance is limited to checking transducer coupling. The converter stores pipe material and wall thickness parameters for each installation, making re-mounting fast. The bidirectional measurement and built-in data logger support energy and water audits without extra hardware.
Installation and Maintenance
Select a straight section with at least 10 diameters upstream and 5 diameters downstream from fittings. Clean the pipe surface, apply ultrasonic coupling gel, and strap the transducers in the correct V-method or Z-method spacing according to the on-screen wizard. Enter pipe outer diameter, wall thickness, and material sound velocity into the converter, then confirm the signal quality bars. For buried pipes, dig a small access pit. During maintenance, re-apply coupling gel every year or if signal strength drops, and inspect the strap for corrosion. Record each mounting location in the commissioning file so future service uses the same spot.
Working Principle
The two transducers alternately transmit and receive ultrasonic pulses along a diagonal path across the pipe. When the liquid is stationary, the upstream and downstream travel times are equal. When the liquid flows, the downstream pulse arrives earlier and the upstream pulse later, and the time difference is proportional to the average flow velocity along the path. The converter combines the time difference with the pipe dimensions to compute volumetric flow. Because the measurement is external, there is no pressure loss and no wetted parts to corrode.
Selection Guide
Choose the standard transducers for pipes DN50 to DN300. For larger pipes up to DN1000, select the large transducer set. For hot pipes above 120 C, choose the high temperature transducer. For buried pipes, order the extension cable and external mounting kit. The meter is suitable for clean water and low-sediment liquids; it is not suitable for liquids with high air bubble content or heavy sludge. For energy billing, order the dual PT100 temperature input version to compute thermal energy.
Each converter ships with transducers, coupling gel, mounting straps, and a quick-start guide. Optional accessories include a rechargeable battery pack, a weatherproof enclosure, and a data logger. KITOZER provides pre-configured units for common pipe materials and sizes, which arrive ready to install. Spare transducers and coupling gel are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom sizes or special materials can be ordered with a short lead time. The installation manual includes wiring diagrams and mounting dimensions for common pipe and cabinet configurations, and engineers can request a loop check sheet for commissioning. The device is compatible with common PLC and DCS systems, and Modbus or HART options allow direct integration into SCADA without additional converters. Long-term spare parts availability is guaranteed for at least 10 years after product discontinuation. The converter supports multi-drop Modbus networks and stores pipe parameters for up to 10 installations.
NIST-traceable calibration is available on request.Price
From $680/pc. Contact +86 13922289957 for clamp-on ultrasonic flowmeter pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com