KITOZER 1000kW Open Frame Diesel Generator For Mission Critical

The KITOZER 1000 kW open frame diesel generator is a mission-critical power plant module delivering 1250 kVA for hyper-scale data centers, large hospitals, airports, and heavy industry. Powered by a V12 or V16 turbocharged aftercooled diesel engine with common rail fuel injection and matched to a Class H brushless alternator, the set is engineered for N+1 redundancy, long runtime fuel systems, and remote supervisory control. The open skid is supplied with all interface points pre-drilled, allowing contractors to mount the unit inside a purpose-built acoustic container or permanent generator room.

Technical Specifications

Standby 1100 kW (1375 kVA), prime 1000 kW (1250 kVA), 400V 50Hz three-phase, power factor 0.8. Engine: V12 or V16, water-cooled, turbocharged, aftercooled, common rail, 1500 rpm. Alternator: brushless, PMG, AVR, class H, IP23, 2/3 pitch, harmonic neutral. Controller: deep-sea DSE890 or ComAp IntiGen NT, color touch, Modbus TCP, SNMP, BACnet, paralleling up to 16 units. Circuit breaker: 2000A drawout air circuit breaker. Battery 24V 400Ah twin. Dimensions approximately 6000 x 2000 x 2600 mm, dry weight 18000 to 22000 kg. Fuel consumption at 75 percent load around 220 L per hour.

Key Advantages

The 1000 kW unit is delivered with full factory load bank test, including step-load response, voltage dip recovery, thermal imaging, and exhaust emission baseline. The engine features electronically controlled wastegate turbochargers, water-cooled exhaust manifold, and a pre-lube system that ensures oil pressure before cranking. The alternator is fitted with space heaters, RTD temperature sensors in each phase winding, and surge suppression for lightning protection. The control system supports load sharing, base load, peak shaving, and mains peak lopping modes, and communicates with SCADA, DCIM, and BMS platforms via standard protocols.

Applications

This class is specified by hyper-scale data centers, cloud computing hubs, large regional hospitals, university campuses, airports, and railway traction substations. Heavy industry including aluminum smelters, paper mills, and petrochemical plants uses 1000 kW sets as emergency standby for critical processes. Remote mining, oil, and gas camps run multiple units in parallel as prime power, often 24 hours per day. Island micro-grids and large agricultural operations also deploy this rating to stabilize weak utility networks.

Installation and Maintenance

Installation requires a structural raft designed for the 20 tonne mass plus dynamic reaction, with spring isolation and fuel oil resistant coating. Room ventilation must remove approximately 50000 kJ per minute of heat, with dedicated inlet and outlet ducts and emergency dampers. The exhaust system uses 10-inch insulated piping, heavy flex, and industrial silencer. The fuel system includes a day tank of at least 2000 L, a sealed storage tank farm sized for 24 to 72 hours, leak detection, and water drain. Power cabling is typically busbar rather than cable, with drawout circuit breaker maintenance bypass.

Maintenance intervals: oil and filter every 250 hours, fuel filter every 500 hours, coolant every 2 years, valve adjustment every 3000 hours, top-end overhaul around 30000 hours. Quarterly load bank tests, monthly exercise under 30 percent load, and annual infrared inspection of all busbar connections are required. KITOZER offers a full service contract including remote monitoring, spare parts inventory, and engineer on-site response within 48 hours for critical sites.

Price

From $145,000 per unit for the 1000 kW open frame set. Contact KITOZER for engine brand options, alternator selection, paralleling switchgear, and CIF pricing. Tel/WeChat: +86 13922289957.