KITOZER Manifold: 8-Way DN10 Stainless Distribution

System Integration Notes

When integrating a KITOZER manifold into a rack or row cooling design, balance the flow across branches by installing balancing valves or restricting orifices where needed. The manifold should be mounted to a rigid structure so that hose weight does not stress the branch connections. Plan for bleed air vents at the highest point of the manifold, and drain points at the lowest. Label each branch valve to correspond with a specific server sled or cold plate. For high-density manifolds, verify that the internal flow passages are sized to keep pressure drop below the design limit across all branches. KITOZER recommends flushing the manifold before connecting cold plates, to remove any manufacturing residue. When expanding a cooling system, add manifolds with the same port configuration and material as the existing installation to maintain spare parts compatibility.

Best Practices

A well-designed manifold installation follows several best practices. First, mount the manifold to a rigid bracket that does not flex under hose load. Second, install a bleed air vent at the highest point and a drain at the lowest, so the loop can be fully purged during commissioning and drained during maintenance. Third, label each branch valve with the corresponding equipment identifier, so that the correct branch is isolated every time. Fourth, verify flow balance across branches after commissioning, using a clamp-on flow meter or by measuring temperature drop across each branch. KITOZER recommends re-checking flow balance after six months of operation, as branch resistance can shift as seals and filters load. Fifth, carry a spare branch valve cartridge on site, so that a leaking valve can be rebuilt without replacing the entire manifold. Finally, document the manifold part number, installation date, and branch configuration in the as-built drawings, so that future expansion uses matching components.

Price

From $880/pc. Contact +86 13922289957 for 8-way stainless manifold pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

The KITOZER 8-way DN10 stainless steel distribution manifold is a precision-machined header that splits a single cooling supply into eight branches for high-density rack cold plate distribution. CNC-machined from 316L stainless steel bar, the manifold features one DN25 inlet and eight DN10 outlets, each with an integrated ball valve for individual branch isolation. The manifold is designed for deionized water and high-purity glycol loops in direct-to-chip liquid cooling racks. With a total flow capacity of 100 liters per minute, it supports racks with eight or more cold plate circuits. KITOZER electropolishes the interior to reduce biofilm and fouling, and supplies the manifold with a mill test certificate for traceability.

Product Overview

An 8-way manifold is the standard distribution device in high-density GPU and GPU server racks, where eight cold plate branches must be fed from a single CDU connection. The manifold body is CNC-machined from solid 316L stainless steel bar, with smooth internal passages that minimize turbulence and pressure drop. Each branch outlet has a compact ball valve, allowing individual cold plates to be isolated for service without shutting down the entire rack. The inlet is a single DN25 port, and the eight outlets are arranged in two rows of four for neat hose routing. The manifold mounts on the rack rear or side, and is available with mounting brackets. The body is passivated to ASTM A967 and electropolished on the interior for cleanability.

Technical Specifications

Body: 316L stainless steel, CNC-machined from solid bar, electropolished interior. Inlet: DN25 G1 male thread. Outlets: 8 x DN10 G3/8 male thread with integrated ball valves. Working pressure: 16 bar. Temperature range: minus 20 to 150 degrees Celsius. Total flow: up to 100 l/min. Mounting: 4 x M6 brackets included. Weight: 4.5 kg. Certification: CE, PED. KITOZER, 5 year warranty. Mill certificate: EN 10204 3.1. Branch valve: EPDM seals, locking handle.

Applications

Primary applications include high-density GPU rack cold plate distribution, GPU training server rack cooling, multi-sled server rack manifolds, and battery ESS module cooling distribution. The manifold is also used in semiconductor tool cooling, HPC cluster rack distribution, and medical imaging equipment cooling where 316L cleanliness is required. In edge computing cabinets with eight or more compute sleds, the 8-way manifold provides a single distribution point. Additional installations include telecommunications base station liquid cooling, aerospace avionics test cooling, and renewable energy power converter cooling. The manifold is suitable for deionized water, high-purity glycol solutions, and dielectric fluids.

Advantages and Features

The 316L stainless steel construction handles deionized water and high-purity loops without ion leaching. Integrated ball valves on each branch allow individual cold plate isolation. CNC-machined from solid bar, the manifold eliminates welds and leak points. The electropolished interior reduces biofilm growth and fouling. Compact size fits in rack rear channels. The 16 bar working pressure accommodates primary loop installations. Color-coded branch ports simplify installation. The manifold is rebuildable with replacement ball valve cartridges. PED certification supports European pressure vessel requirements. The single-inlet design simplifies CDU connection.

Installation and Maintenance

Mount the manifold securely with the supplied brackets. Use PTFE tape on threaded connections. Connect the CDU supply to the inlet and cold plate hoses to the outlets. After filling, bleed air from the highest point. Inspect ball valves annually for smooth operation. Lubricate valve stems with silicone grease. Check for leaks after commissioning. Flush the loop annually to remove sediment. Label each branch valve to correspond with a specific server sled or cold plate. When isolating a branch for service, record the valve position. Replace ball valve cartridges every five years or if weeping is observed at the stem. Keep a maintenance log of all valve operations.

System Integration Notes

When integrating a KITOZER manifold into a rack or row cooling design, balance the flow across branches by installing balancing valves or restricting orifices where needed. The manifold should be mounted to a rigid structure so that hose weight does not stress the branch connections. Plan for bleed air vents at the highest point of the manifold, and drain points at the lowest. Label each branch valve to correspond with a specific server sled or cold plate. For high-density manifolds, verify that the internal flow passages are sized to keep pressure drop below the design limit across all branches. KITOZER recommends flushing the manifold before connecting cold plates, to remove any manufacturing residue. When expanding a cooling system, add manifolds with the same port configuration and material as the existing installation to maintain spare parts compatibility.

Best Practices

A well-designed manifold installation follows several best practices. First, mount the manifold to a rigid bracket that does not flex under hose load. Second, install a bleed air vent at the highest point and a drain at the lowest, so the loop can be fully purged during commissioning and drained during maintenance. Third, label each branch valve with the corresponding equipment identifier, so that the correct branch is isolated every time. Fourth, verify flow balance across branches after commissioning, using a clamp-on flow meter or by measuring temperature drop across each branch. KITOZER recommends re-checking flow balance after six months of operation, as branch resistance can shift as seals and filters load. Fifth, carry a spare branch valve cartridge on site, so that a leaking valve can be rebuilt without replacing the entire manifold. Finally, document the manifold part number, installation date, and branch configuration in the as-built drawings, so that future expansion uses matching components.

Price

From $880/pc. Contact +86 13922289957 for 8-way stainless manifold pricing.