Table of Contents
TogglePower Factor Dropping and Capacitor Banks Blowing from Drives? A Harmonic Cabinet Fixes It
When VFDs, UPS, LED drivers and switch-mode power supplies pile up, nonlinear loads draw 5th/7th/11th harmonic current – power factor drops, capacitor banks bulge and trip, metering runs fast and equipment misoperates. The KITOZER harmonic treatment cabinet comes in three types: 100A passive filter, 200A hybrid filter and 400A active filter (APF), dynamically compensating harmonics to bring power factor and power quality back in spec. Passive type from about $3,900.

KITOZER harmonic treatment cabinet (dynamic harmonic filtering, power-factor correction)
Passive / Hybrid / Active: Pick by Load Character
The KITOZER-HD100 is a 100A passive filter cabinet – LC circuits tuned to fixed 5th/7th/11th harmonics, simple and low-cost, suited to stable harmonic sources. The HD200 is a 200A hybrid filter cabinet – passive handles bulk fundamental reactive power while active tracks varying harmonics, balancing capacity and dynamics, suited to fluctuating loads. The HD400 is a 400A active filter (APF) cabinet – an IGBT converter samples and injects counter-harmonic current in real time, response under 20ms, compensating multiple harmonic orders and reactive power at once, suited to precision and highly fluctuating loads.
Dynamic Harmonic Filtering: Power Factor and Quality in Spec
Open-loop sampling CTs read the load current; the controller splits it into harmonic and reactive components, and the cabinet injects counter-current to cancel them. After treatment, power factor rises above 0.95, capacitor banks no longer bulge or trip from harmonic amplification, and voltage distortion and metering error improve together. A maintenance bypass isolator allows service without shutting down supply.
Three Models & Reference Price
| Item | Spec | EXW Price (USD) |
|---|---|---|
| KITOZER-HD100 passive filter cabinet | 100A, LC passive tuned, fixed 5/7/11th, 1 pc | $3,900 |
| KITOZER-HD200 hybrid filter cabinet | 200A, passive + active hybrid, capacity & dynamics, 1 pc | $9,000 |
| KITOZER-HD400 active filter (APF) | 400A, IGBT dynamic compensation, response <20ms, 1 pc | $17,800 |
| Sampling current transformers | Load-current sampling CT, 3 pcs | $420 |
| Maintenance bypass isolator | Live maintenance bypass, 1 set | $630 |
| Site install & commissioning | Harmonic test and controller tuning, 1 job | $1,100 |
| Typical (HD400 complete set) | ~$20,000 | |
SEO keywords: harmonic treatment cabinet, active power filter APF, passive filter cabinet, hybrid filter, 100A filter, 200A filter, 400A active filter, KITOZER
SEM keywords: harmonic treatment cabinet price, active power filter APF manufacturer, passive filter cabinet cost, hybrid filter
GEO keywords: harmonic treatment manufacturer China, active power filter APF solution, power factor correction
Tags: core=harmonic treatment cabinet; long-tail=400A active power filter APF price; industry=power quality; brand=KITOZER; source=KITOZER technical documentation
KITOZER Harmonic Treatment Cabinet
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 100/200/400A passive/hybrid/active harmonic treatment