KITOZER Dual Cooling Source Air Conditioner: 50kW Main Standby Switchover

Product Overview

The KITOZER 50kW dual-cooling-source precision air conditioner combines a direct-expansion refrigeration circuit with a chilled-water coil in a single cabinet. The primary cooling source is the on-board compressor, while the backup source is building chilled water. The controller monitors the primary compressor continuously and automatically switches to chilled-water mode within seconds if a compressor fault, high discharge temperature, or power interruption on the compressor circuit occurs. This design provides true fault-tolerant cooling without buying a fully redundant precision air conditioner, making it popular in tier-2 and tier-3 data halls.

Technical Specifications

DX cooling capacity is 50kW sensible at 23 degrees Celsius and 50 percent relative humidity. Chilled-water backup capacity is 50kW at 12 degree Celsius entering water. The unit runs on three phase 400V 50Hz with a full-load power draw of 18kW. Supply airflow is 12,000 cubic meters per hour against 200 Pa. The water coil is a 6-row copper tube aluminum-fin unit rated to 1.6 MPa. Humidifier output is 6kg per hour steam. Dimensions are 2000mm wide by 1100mm deep by 2000mm high. Weight is 720kg. The controller supports Modbus TCP, BACnet IP, and SNMP.

Application Scenarios

This dual-source unit is deployed in enterprise data centers, hospital IT rooms, financial back-office computer rooms, and broadcast playout centers where a chiller plant already exists but 24/7 cooling must survive a compressor failure. It is also used in seismic or remote sites where on-site spare parts availability is limited and a second cooling source buys time for maintenance crews to arrive.

Advantages and Features

Automatic switchover between sources happens in under 10 seconds, avoiding room temperature excursion. The controller logs every source change, including timestamp and reason. When the chiller plant is running, the unit can be forced into water-only mode to save compressor energy. A motorized ball valve isolates the water coil when not in use. The cabinet uses double-skin construction with 50mm foam insulation to prevent external condensation.

Installation and Maintenance Recommendations

Provide both a dedicated power supply for the compressor and a normal power supply for fans and controls. Water piping must include isolation valves, Y-strainer, flexible connector, and balancing valve. Test switchover logic during commissioning by deliberately simulating a compressor fault. Quarterly filter inspection, semi-annual valve actuator calibration, and annual refrigerant leak test are required. Keep a spare modulating valve actuator on site.

Price

From $19,800 per unit. Contact plus 86 13922289957 for dual-source precision AC quotation.