The KITOZER 5kW thermal management unit is a dedicated air conditioner for battery energy storage containers and walk-in battery rooms. It keeps the LFP battery band within a tight 25 to 35 degrees Celsius window, which directly extends cycle life and reduces cell-to-cell spread. The unit is built for outdoor installation on the container side wall, with a built-in electric heater for cold climates and an eco-friendly refrigerant.
Table of Contents
ToggleProduct Overview
KITOZER designs the 5kW HVAC as a split or through-wall unit. The indoor side draws hot air from the battery aisle through a filter, cools it over an evaporator coil, and discharges it back into the aisle. The outdoor side rejects heat to the ambient air through a condenser. A four-way valve allows the same unit to heat the room in winter, keeping the battery above 10 degrees Celsius when charging would otherwise be prohibited. The controller reads battery temperature from the BMS over Modbus and adjusts cooling capacity to hold the average cell temperature set point, rather than cycling on a fixed room thermostat.
Technical Specifications
Cooling capacity 5kW at 35 degrees Celsius ambient. Heating capacity 3kW with electric heater. Power supply 230V single phase, 50Hz. Rated power 1.8kW cooling, 3kW heating. Refrigerant R410A or R32. Air flow 1200 cubic meters per hour. Communication Modbus RTU, dry contacts. Operating temperature minus 30 to plus 55 degrees Celsius. Protection IP55 outdoor section. Dimensions 1100 x 600 x 400 millimeters, weight 95 kilograms. Certifications CE, ISO 5151. KITOZER three-year warranty.
Application Scenarios
This HVAC is installed in 20-foot and 40-foot battery containers that house 1MWh to 5MWh of LFP racks, and in walk-in battery rooms at data centers and telecom hubs. It is also used in outdoor battery cabinets that need a compact thermal solution when the ambient exceeds 40 degrees Celsius. Integrators typically install two 5kW units in parallel on a 20-foot container, so that one unit can fail while the other holds the temperature band.
Key Advantages
Modbus integration with the BMS lets the HVAC react to actual battery temperature instead of room air temperature, which keeps the cell band tighter. The built-in heater removes the need for a separate electric heating strip and its own safety circuit. Two units in parallel provide N plus 1 redundancy, so a single fan failure does not trigger a battery derating alarm. The through-wall design avoids the need for long duct runs, which saves container space and reduces thermal losses.
Installation and Maintenance
Cut the wall opening to the dimensions in the installation drawing, seal the unit with foam gasket, and anchor it with the provided brackets. Connect the condensate drain to a heated trap in cold climates, and route the Modbus cable away from the power cables. Commissioning includes setting the battery temperature set point, testing the heater interlock, and verifying that the HVAC alarm relay opens when the filter is clogged. Annual maintenance includes cleaning or replacing the air filter, checking the refrigerant pressure, and testing the condensate pump. Keep a spare filter and a spare fan on site to minimize downtime in remote containers.
Price
From $1,480 per unit. Contact KITOZER for container HVAC bundles with redundant units and controllers.