The KITOZER 40kW water-cooled rear door heat exchanger (RDHx) replaces the rear door of a standard server rack, absorbing hot exhaust air directly as it leaves the equipment. Water-cooled coils inside the door capture the heat before it enters the hot aisle, eliminating recirculation and allowing rack densities to rise to 30kW or more without raising room air temperature. The RDHx contains no fans or compressors: it relies on the server rack fans to push air through the coil, making it intrinsically silent and energy neutral from a parasitic load perspective.
Technical Specifications
Rated heat rejection is 40kW at 35 degrees Celsius entering air and 25 degree Celsius entering water. Coil is copper tube with brazed fins, rated to 1.6 MPa working pressure. Water flow is 2.0 liters per second at design delta-T of 5 degrees. Pressure drop across the coil is 25 kPa. The door matches standard 19 inch rack widths of 600mm or 800mm and opens like a hinged door for rear service. Weight is 95kg. Finish is black powder coat. Connection fittings are quick-connect dry-break couplings. Optional controls include a 0 to 10V motorized valve and temperature sensors routed to the rack management unit.
Application Scenarios
RDHx units are used in high-density AI compute racks, GPU clusters, crypto mining containers, telecommunications central offices, and retrofit projects where existing room cooling cannot be upgraded. They are also popular in edge sites with limited floor space and in laboratories running power electronics, battery cyclers, and RF test equipment that generate dense local heat.
Advantages and Features
Capturing heat at the rack exhaust eliminates hot spots and allows the rest of the data hall to operate at higher supply temperatures, improving chiller efficiency. No fan power means zero parasitic energy. Quick-connect couplings allow door removal in seconds without draining the loop. The hinged design preserves full rear access to servers. Modbus integration allows per-rack temperature and water flow monitoring. High inlet water temperature options (up to 32 degrees Celsius) enable free cooling from dry coolers for most of the year.
Installation and Maintenance Recommendations
A pressurized water loop with supply and return manifolds must be installed in the floor or overhead. Each RDHx connects via braided stainless steel hoses with ball valves. Water treatment is essential to prevent fouling; a 50 micron strainer should be installed at each connection. Inspect hoses annually for wear and replace every 5 years. Coil cleaning with low-pressure water occurs every 2 to 3 years, depending on dust loading.