KITOZER Dry Transformer: 1000kVA 10kV/0.4kV Cast Resin

KITOZER 1000kVA cast resin dry type transformer steps 10kV distribution voltage down to 400V for commercial and industrial loads. Because the windings are cast in epoxy resin, the transformer has no oil, no leakage risk, and no fire hazard, making it suitable for indoor installation in occupied buildings, underground substations, and high rise towers. This model offers low no-load loss, low noise, and reliable performance in dusty or damp environments.

Product Overview

The transformer consists of silicon steel sheet cores wound with copper foil or copper conductors, encapsulated in vacuum cast epoxy resin. The high voltage winding is wound on the outside and the low voltage winding on the inside, both insulated by resin. Cooling is by natural air (AN) or forced air (AF) with optional fans that raise output by 40 percent. A temperature controller monitors Pt100 sensors embedded in the windings, giving alarm and trip signals at preset temperatures. The enclosure can be IP00 open type or IP21/IP23 sealed for dust protection.

Technical Specifications

Rated power 1000kVA, primary voltage 10kV plus or minus 2 times 2.5 percent, secondary voltage 400V, connection Dyn11, impedance 6 percent, frequency 50/60Hz. No-load loss 1770W, load loss 10300W at 120 degrees Celsius, insulation class F or H, temperature rise 100K for class F. Noise level 55dB. Cooling AN or AF, ambient temperature minus 5 to plus 40 degrees Celsius. Enclosure IP21 standard, optional IP23. Compliant with IEC 60076-11 and GB/T 1094.11.

Applications

This transformer is used in commercial building substations, shopping malls, hospitals, data centers, and industrial plants where oil transformers are prohibited by fire codes. It is also installed in underground vaults, high rise towers, and offshore platforms where space is limited and leakage would be dangerous. Common secondary loads include LED lighting, HVAC, elevators, UPS, and production machinery. Forced air cooling allows the same unit to supply short time overloads during peak demand.

Advantages

No oil means no bunding, no oil testing, and no fire risk, cutting civil work cost and insurance premium. Epoxy resin windings resist moisture and dust, allowing operation in humid industrial environments. Low no-load loss meets modern efficiency regulations and reduces standby electricity bills. Dyn11 connection suppresses triplen harmonics and provides a stable neutral for single phase loads. Temperature monitoring protects windings from overheating. The unit is recyclable at end of life with minimal environmental impact.

Installation and Maintenance

Place the transformer on a level, well ventilated plinth with clearance around it for airflow. Connect primary and secondary cables with flexible connectors to avoid mechanical stress on the bushings. Ensure the neutral earthing matches the system design. Commissioning includes insulation resistance, ratio, no-load, and impedance tests before energization. The temperature controller must be calibrated and alarm thresholds verified. Maintenance annually includes cleaning dust from the core and windings with dry compressed air, checking fan operation, and tightening terminals. Inspect the resin surface for cracks every five years. Keep ventilation grilles clear to avoid hot spots.

Price

From $11,800/pc. Contact +86 13922289957 for transformer pricing.