KITOZER In-row Air Conditioner: 30kW Air Cooled High Density

Product Overview

The KITOZER 30 kW air-cooled in-row air conditioner is a rack-height cooling unit designed to sit directly between server racks in hot-aisle or cold-aisle containment. By placing cooling close to the heat source, the in-row unit eliminates long duct runs and hot-spot formation that often plague traditional room-level precision air conditioners in high-density halls. The cabinet matches a standard 19 inch rack footprint, drawing warm exhaust air from the hot aisle and discharging cool air into the cold aisle. A single inverter compressor, EC plug fan, electronic expansion valve, and optional humidifier deliver tight control at partial load. The front door is hinged for tool-less filter and coil access, and the unit ships fully wired and factory-tested.

Technical Specifications

Nominal cooling capacity is 30 kW sensible at 27 degrees Celsius entering air and 50 percent relative humidity. The unit runs on three phase 400 V 50 Hz with a maximum power draw of 11 kW. Supply airflow is 7000 cubic meters per hour against 70 Pa external static pressure. Refrigerant R410A is piped to an outdoor V-type air-cooled condenser up to 30 meters away. Humidification is 4 kg per hour steam. Dimensions are 600 mm wide by 1200 mm deep by 2000 mm high, matching a standard rack bay. Weight is 320 kg. Noise is 66 dBA at 3 meters. The controller supports Modbus TCP, BACnet IP, and SNMP. The cabinet is painted RAL 7035 light grey with a scratch-resistant powder coat.

Application Scenarios

This 30 kW in-row unit is ideal for high-density server racks of 8 to 15 kW per rack, AI training clusters, GPU compute nodes, storage area networks, and high-frequency trading cages. It is equally at home in edge computing facilities, 5G core node rooms, and retrofit projects where raised floors are absent. Hot-aisle containment paired with in-row cooling is the dominant architecture for modern data centers targeting PUE below 1.3. The unit is also used in telecom central offices, medical imaging equipment rooms, and industrial automation control floors.

Advantages and Features

Proximity to IT equipment eliminates hot-aisle recirculation and cold-aisle bypass, raising cooling efficiency. The inverter compressor modulates from 20 to 100 percent capacity, avoiding the on-off cycling that wastes energy in fixed-speed units. EC fans communicate over 0 to 10 V control and can be tied to rack inlet temperature sensors. The controller supports group sequencing across multiple in-row units, with automatic duty rotation and alarm escalation. Front-to-front airflow orientation simplifies aisle containment installation. The cabinet is painted with scratch-resistant powder coat and uses tool-less filter access. The unit also supports remote firmware updates, so control logic improvements can be deployed without a service visit. A built-in web server exposes live trends and alarm history to any authorized browser on the local network.

Installation and Maintenance Recommendations

The unit bolts directly to the floor or rack rail using standard mounting hardware. Refrigerant lines should be sized to minimize pressure drop, with isolation valves at the outdoor condenser. Power and communication cables route through the bottom cable tray. Filters are G4 and should be inspected every 90 days. The condenser coil should be washed annually in dusty environments. Compressor and fan vibration should be checked annually. Keep spare filters, fuses, and a humidifier cylinder on site to minimize mean time to repair. Commissioning should include a group-sequencing test that proves adjacent units take over when one alarms. A thermal imaging walk-through after commissioning confirms that no rack inlet exceeds the design setpoint. Operators should be trained on alarm acknowledgment, filter replacement, and the procedure for isolating a faulty unit without taking the aisle offline.

Energy and Environmental Performance

In-row cooling raises supply air temperature setpoints compared with room-level cooling, because cold air does not have to travel across the room. This allows the outdoor condenser to run at lower condensing pressure, saving energy. The inverter compressor and EC fans combine to deliver a part-load EER above 3.2. R410A refrigerant has no ozone depletion potential, and the cabinet uses CFC-free foam insulation. The unit supports remote setpoint adjustment, letting operators raise supply temperature during low-utilization periods. Over a year, these setpoint changes can reduce compressor runtime by several hundred hours, paying back the unit premium within a few cooling seasons.

Configuration Options and Warranty

The unit is offered in air-cooled, water-cooled, and chilled-water variants, and with upflow or downflow discharge to match aisle layouts. Optional extras include a humidifier, a 4G remote monitoring gateway, a stainless-steel front for coastal sites, and a high-static fan option. The standard warranty covers the compressor for 3 years and the cabinet for 1 year, with extended coverage up to 5 years available. Factory commissioning and operator training are recommended for multi-unit arrays. A preventive maintenance package with quarterly visits is available for mission-critical installations.