KITOZER VCB: 10kV 1250A Vacuum Circuit Breaker For Transformer Feeder

KITOZER 10kV 1250A vacuum circuit breaker is a medium-voltage protection device engineered for transformer feeders, main incoming panels, and large industrial motor branches. Rated at 1250A continuous current with 25kA short-circuit breaking capacity, this VCB combines compact withdrawable dimensions with robust fault interruption performance. The vacuum interrupter ensures silent, repeatable switching without arc gas exhaust, and the spring stored energy mechanism guarantees operation even under control supply failure. The breaker is designed to coordinate with upstream and downstream protection devices so that only the faulted section is isolated while the rest of the distribution network stays energized.

Product Overview

The breaker is built around three cast resin poles containing sealed vacuum interrupters, driven by a common spring operating mechanism mounted on a withdrawable truck. Primary isolation is achieved by racking the truck to the test or isolated position, where visible air gaps separate the primary contacts from the bus. Auxiliary circuits are wired through pluggable secondary connectors so the truck can be removed without rewiring. Mechanical interlocks prevent closing when the truck is not fully seated, and a padlockable shutter covers the bus contacts for personnel safety. The truck rolls on steel wheels guided by the switchgear rails, and a crank handle racks the truck between connected, test, and disconnected positions with positive detents at each stop.

Technical Specifications

Rated voltage 12kV, rated frequency 50/60Hz, rated normal current 1250A, rated short-circuit breaking current 25kA, rated short-time withstand 25kA for 4s, rated peak withstand 63kA, rated operating sequence O-0.3s-CO-180s-CO, lightning impulse withstand 75kV peak. Motor charging voltage options DC110V/220V or AC110V/220V, shunt close and trip coils, undervoltage release optional, auxiliary contacts 8NO+8NC standard. Mechanical endurance 10,000 operations, electrical endurance 10,000 operations at rated current, ambient temperature minus 25 to plus 40 degrees Celsius, installation altitude below 1000m, pollution class 3. The contact resistance per pole is held below 18 micro ohms at factory test, and the average closing time is below 70ms with opening time below 40ms under rated control voltage. Compliant with IEC 62271-100 and GB 1984.

Applications

This 1250A VCB is typically used as the main breaker on the 10kV side of 1000kVA to 2000kVA distribution transformers in industrial plants, commercial towers, hospital and campus power houses. It also serves as the incoming and bus-tie breaker in KYN28A switchgear rooms, as protection for large medium-voltage motors such as induced draft fans, cooling water pumps, and mill drives, and as the collector circuit breaker in industrial solar and storage power stations. Its higher current rating makes it suitable for dense urban load pockets where transformer sizes are growing. In industrial plants, the breaker often feeds a medium voltage motor control center that supplies several large drives, and in data centers it protects the UPS input feeder where any momentary interruption must be cleared within one cycle.

Advantages

Compared with air magnetic breakers, vacuum interrupters offer contact life measured in tens of thousands of operations and no routine gas refilling. The sealed resin pole prevents tracking and flashover in damp or dusty environments. The common spring mechanism reduces spare parts inventory across multiple breakers in the same switchroom. Withdrawable construction cuts maintenance downtime to minutes when a truck swap is performed. Low audible noise and no exhaust hot gas allow installation close to occupied areas. The breaker pairs with microprocessor protection relays to provide overcurrent, earth fault, and transformer differential protection coordination. Standardized dimensions allow the truck to be moved between spare and duty positions, so a faulty breaker can be replaced without a long outage while the unit is repaired in the workshop.

Installation and Maintenance

Slide the truck onto the switchgear rails, confirm the secondary plug engages, and rack in to the connected position. Perform contact resistance measurement at no more than the manufacturer specified value before energization. Check spring charge indication, counter operation, and auxiliary contact signals against the protection relay logic. During preventive maintenance every three years, measure vacuum interrupter pressure via power frequency withstand test, inspect contact wear, lubricate the mechanism linkages, and verify torque on primary and secondary connections. Keep a log of total mechanical operations and plan interrupter replacement before the wear limit is reached. Spare parts kits including closing coil, tripping coil, and auxiliary switch are recommended for stock. When a breaker trips on fault, inspect the interrupter and contact surfaces before re-energization, and record the fault current magnitude to schedule the next overhaul interval accordingly.