KITOZER KYN28A-12 metalclad withdrawable switchgear is the standard 10kV indoor switchboard used in distribution substations, industrial plants, and commercial buildings. It houses a vacuum circuit breaker on a withdrawable truck, with segregated compartments for bus, cable, and relay rooms. KYN28A is the most widely adopted medium voltage switchgear type, offering high reliability, easy maintenance, and full protection coordination.
Table of Contents
ToggleProduct Overview
The switchgear is a steel sheet cubicle divided into four compartments: busbar compartment, breaker truck compartment, cable compartment, and relay compartment. Shutters close automatically over the bus contacts when the truck is racked out, isolating live parts. Mechanical interlocks prevent incorrect operations. A pressure relief duct at the top directs internal arc gases away from personnel. Breaker trucks are interchangeable between panels, allowing fast swap during maintenance.
Technical Specifications
Rated voltage 12kV, rated frequency 50/60Hz, rated current up to 1250A or 1600A, rated short-time withstand 25kA for 4s, peak withstand 63kA, power frequency withstand 42kV for 1 minute, lightning impulse 75kV peak. Breaker VCB 1250A 25kA. Protection class IP2X for accessible surfaces. Internal arc classification IAC AFLR for 1s optional. Compliance with IEC 62271-200 and GB 3906.
Applications
KYN28A panels are used as the main 10kV switchboard in industrial plants, commercial towers, hospital substations, data centers, and water pumping stations. Typical lineups include incoming panel, bus tie panel, transformer feeder panel, capacitor bank feeder, and motor feeder panels. The withdrawable breaker allows fast maintenance and easy spare truck handling. It is the default choice for new 10kV indoor switchrooms.
Advantages
Metalclad segregation ensures that a fault in one compartment does not propagate. Withdrawable breaker truck allows maintenance without de-energizing the main bus. Interlock logic prevents human error. Pressure relief duct protects operators during internal arc faults. Standard dimensions fit most switchroom layouts. Rich accessory options include PT, CT, arresters, and earth switches. Long service life and large installed base mean local support is readily available.
Installation and Maintenance
Assemble panels on a common busbar duct, connect the horizontal busbar, and verify the earthing bus. Commissioning includes breaker functional tests, protection relay injection, interlock verification, and dielectric tests. Maintain annually by inspecting shutters, interlocks, and cable glands; measure contact resistance and vacuum integrity on breakers every three years. Keep one spare breaker truck for critical substations. Train operators on racking procedure and interlock bypass rules.
Price
From $6,800/panel. Contact +86 13922289957 for KYN28A pricing.