KITOZER
KITOZER

KITOZER Industrial Temperature Humidity Sensor RS485 Modbus For Server Room

The KITOZER industrial temperature humidity sensor is a wall-mount multi-sensor probe designed for continuous environmental monitoring in server rooms, data centers, warehouses, pharmaceutical storage, and clean manufacturing areas. It combines a calibrated humidity element and a digital temperature sensor in a single vented enclosure, providing accurate readings over a wide operating range. The RS485 Modbus RTU interface allows up to 32 sensors to share a single two-wire bus, reducing cabling cost and simplifying integration with KITOZER monitoring hosts, PLCs, BMS controllers, and third-party SCADA systems.

Unlike consumer-grade temperature humidity sensors that drift within months, the KITOZER industrial sensor uses a factory-calibrated capacitive humidity element with an integrated temperature compensation algorithm. Each unit ships with a calibration certificate traceable to national standards. The sensor samples values every 2 seconds and transmits averaged readings over Modbus, which reduces bus traffic while maintaining response speed. A configurable alarm threshold can trigger the built-in relay output directly, allowing the sensor to act as a standalone limit alarm for fans, heaters, or dehumidifiers without relying on a central controller.

Product Overview

The enclosure is made of ABS plastic with a removable vented cap that protects the sensing element from dust and direct water spray while allowing air circulation. Wall mounting screws and wiring terminals are accessible on the rear. The sensor is powered by 9 to 30 VDC, making it compatible with standard security power adapters and industrial DC buses. An optional OLED display version shows live temperature, humidity, and alarm status on a 0.96-inch screen for on-site verification without a laptop.

Technical Specifications

Temperature range: -40 to +125 C. Temperature accuracy: plus or minus 0.3 C at 25 C, plus or minus 0.5 C across range. Humidity range: 0 to 100 percent RH non-condensing. Humidity accuracy: plus or minus 2 percent RH at 20 to 80 percent RH. Response time: 8 seconds for 63 percent step change. Interface: RS485 half-duplex, Modbus RTU, baud rate 9600 to 115200 bps configurable, address 1 to 247. Power: 9 to 30 VDC, typical 15 mA at 12 VDC. Relay output: 1 x SPDT 1 A 30 VDC, configurable high or low trigger. Enclosure: ABS, IP30, wall mount. Operating temperature: -40 to +80 C. Storage: -40 to +85 C. Certifications: CE, FCC, RoHS. KITOZER warranty: 2 years, calibration certificate included.

Application Scenarios

This sensor is widely used in server rooms for cold aisle and hot aisle monitoring, in pharmaceutical warehouses for temperature and humidity compliance, in food processing areas for humidity control, in greenhouses for climate automation, and in archives and museums for artifact preservation. In a data center, sensors are mounted at rack inlet height to capture the temperature that servers actually experience, rather than the ceiling temperature that older sensors measured. In a pharmaceutical cold storage room, the sensor logs continuous data that can be exported for GMP audit trails.

Advantages and Features

The sensor offers a strong balance of accuracy, durability, and bus flexibility. The Modbus address can be set through a rotary switch or software command, eliminating the need for a special programming tool. The built-in relay provides local alarm control even when the central host is offline. The vented cap is replaceable, which is important in dusty environments where the filter element can clog over time. KITOZER provides a free configuration utility for Windows that reads current parameters, sets address and baud rate, and performs a two-point humidity calibration.

Installation and Maintenance Advice

Mount the sensor at the breathing zone height of the monitored space, typically 1.2 to 1.5 meters above the floor, away from direct sunlight, heat vents, and water spray. For RS485 bus, use shielded twisted pair, keep total bus length under 1,200 meters, and install a 120-ohm termination resistor at the last sensor. Calibrate humidity annually using a saturated salt solution reference; the temperature element rarely drifts and can be checked against a calibrated reference thermometer. Replace the vented cap every 2 years in dusty or oily environments to prevent sensor element contamination.

Typical Deployment Configuration

In a server room, KITOZER temperature humidity sensors are mounted at each rack inlet, typically at 1.5 meters height, spaced every 12 to 15 meters along the cold aisle. All sensors share a single RS485 daisy chain running back to the KITOZER monitoring host, with each sensor assigned a unique address via the configuration software. The host polls every sensor every 5 seconds and displays the readings on a floor plan dashboard. If temperature rises above 27 C or humidity drops below 40 percent, the host triggers an email and SMS alert, and can close a relay output to start an auxiliary exhaust fan or humidifier. In a pharmaceutical warehouse, additional sensors are placed near product pallets, at doorways, and at the evaporator outlet to ensure that storage conditions comply with GSP regulations. The Modbus register map is provided for free integration into any BMS or SCADA platform, and KITOZER engineering support is available to assist with first-time configuration.

Price

From $38 per unit. Contact +86 13922289957 for bulk pricing and calibration certification requirements.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart