The KITOZER 32-point dynamic environment monitoring unit is a mid-range central collector engineered for medium-sized data centers, multi-zone telecom rooms, and enterprise computer rooms that require more sensor capacity than a 16-point unit can provide. It supports up to 32 direct channels and unlimited Modbus expansion, allowing integrators to build a complete monitoring system covering temperature, humidity, water leakage, smoke, infrared intrusion, door status, UPS status, cooling unit parameters, power distribution current, and battery voltage from one hardware platform. The unit runs a real-time multitasking operating system and scans all channels every second, ensuring fast alarm response and accurate trend logging.
Remote management is a core strength. The built-in web server displays live dashboards, historical curves, alarm logs, and configuration pages on any modern browser without requiring client software. Optional SNMP v3 support allows the unit to integrate directly into existing NMS platforms such as Zabbix, PRTG, Nagios, and SolarWinds. For facilities that already run a DCIM system, the Modbus TCP slave interface exposes every channel value as a register, enabling seamless data import. Email, SMS, and WeChat push notifications are supported out of the box, with configurable escalation chains so that unresolved alarms are automatically forwarded to the next duty officer.
Table of Contents
ToggleProduct Overview
The 32-point unit features a 3.5-inch color touchscreen on the front panel for local operation and on-site diagnostics. The metal chassis is designed for 19-inch rack mounting with 1U height, saving valuable cabinet space. Rear terminals are grouped by function to reduce wiring errors: sensor inputs, relay outputs, Ethernet ports, RS485 buses, and power terminals are clearly labeled and separated. A watchdog timer automatically restarts the unit if the operating system hangs, and a real-time clock with battery backup preserves event timestamps across power outages.
Technical Specifications
Processor is a 1 GHz industrial ARM Cortex-A8 with 512 MB RAM and 4 GB eMMC storage. Ports: 2 x Gigabit Ethernet, 8 x RS485 (Modbus RTU master and slave), 16 x dry contact inputs, 8 x relay outputs (5 A 250 VAC), 1 x USB 2.0, 1 x VGA for local monitor expansion. Direct channel capacity: 32 analog and digital inputs. Expandable Modbus points: up to 512 total. Temperature accuracy: plus or minus 0.3 C for Pt1000 probes; humidity accuracy plus or minus 2 percent RH. Event log: 500,000 records with 1-second resolution. Alarm channels: configurable thresholds, deadbands, delays, and linkage actions. Operating power: 100 to 240 VAC 50/60 Hz, consumption less than 15 W. Operating temperature: -10 to +60 C. Certifications: CE, FCC, RoHS, ISO 9001. KITOZER warranty: 5 years.
Application Scenarios
This unit is ideal for medium data centers of 20 to 100 racks, regional telecom hubs, banking data processing centers, hospital central IT rooms, university computer centers, and industrial process control rooms. A typical deployment might divide the floor into four monitoring zones, each with its own temperature and humidity sensors, leak detection cables, smoke detectors, and door contacts. The unit also connects to third-party devices such as UPS systems, precision air conditioners, power distribution units, and battery monitoring systems over RS485, giving operators a unified view of both environmental and electrical health.
Advantages and Features
The KITOZER 32-point unit stands out for its open protocol support and scalable architecture. Unlike closed proprietary monitoring systems that force customers into a single vendor sensor ecosystem, the KITOZER unit accepts standard Modbus RTU and TCP devices from any manufacturer. This protects existing investment and reduces integration cost. The touchscreen interface is intuitive enough for non-technical staff to check status, while the register map is detailed enough for BMS engineers to map every point. Dual Ethernet ports with VLAN support allow segmentation between the office network and the sensitive IT management network, improving cybersecurity posture.
Installation and Maintenance Advice
Mount the unit in a 19-inch rack with adequate clearance on both sides for cable bending radius. Use shielded Ethernet cables and connect both network ports to separate switches for redundancy. Label each sensor cable at both ends with channel number and location to speed troubleshooting. Perform a full alarm simulation test after commissioning: trip each sensor, confirm the correct alarm text appears on the web interface, verify email and SMS delivery, and check relay linkage. Download the configuration file after commissioning and store it offline. Schedule quarterly calibration of temperature and humidity probes, and replace backup batteries every 3 years.
Typical Deployment Configuration
In a medium-sized data center with 30 racks, a KITOZER 32-point unit is installed in the main monitoring cabinet and wired to four environmental zones. Each zone has a temperature humidity sensor at rack inlet height, a positioning leak cable along the floor, a smoke detector, and a door contact. The unit also polls two UPS systems, three precision air conditioners, and eight PDU breakers over RS485. The web dashboard displays a floor plan with color-coded sensor icons, and alarm escalation is configured so that a warning email goes to the maintenance team, a major alarm triggers an SMS, and a critical leak or smoke event triggers an automated phone call to the duty engineer. This configuration reduces the time between an incident and human response from tens of minutes to under two minutes, which is critical for IT equipment that can fail within minutes of overheating.
Price
From $980 per unit. Contact +86 13922289957 for project-based quotation and sensor bundle pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com