The KITOZER three-phase power monitoring module is a DIN-rail energy meter that measures voltage, current, power factor, active energy, reactive energy, harmonics, and frequency on a three-phase four-wire distribution system. It is designed for data center PDU monitoring, building sub-metering, industrial energy management, and UPS input output trending. The module connects directly to line voltage and to split-core current transformers, and it publishes all measurements over Modbus TCP, Modbus RTU, and optional MQTT to a central monitoring platform.
Unlike basic watt-hour meters that only record total energy, this module provides real-time electrical parameters on every phase. Facility teams can see phase voltage imbalance, current unbalance, total harmonic distortion, and power factor at a glance. This data is essential for data center operators who must report PUE, identify overloaded circuits, and detect harmonic problems caused by UPS and VFD loads. The module also supports demand tariff calculation, making it suitable for industrial sites with time-of-use billing.
Table of Contents
ToggleProduct Overview
The module is a 4-module width DIN-rail device with a front LCD display that cycles through voltage, current, power, and energy readings. Terminal blocks on the rear accept three-phase voltage input, neutral, and up to four current transformer inputs. An Ethernet port on the front panel provides Modbus TCP, and a serial port provides Modbus RTU. A web configuration page allows IP address, CT ratio, and tariff settings to be changed without proprietary software.
Technical Specifications
Voltage input: 3 x 230/400 VAC, 50/60 Hz. Current input: via external CT, 5 A secondary, CT ratio configurable from 50/5 to 3000/5. Measurement accuracy: class 0.5S for active energy, class 0.5 for voltage and current. Measurements: V, A, W, VA, var, PF, frequency, kWh, kvarh, THD per phase. Harmonics: up to 31st. Communications: 1 x Ethernet 10/100, Modbus TCP, 1 x RS485 Modbus RTU, optional MQTT. Power supply: 100 to 240 VAC. Display: LCD, backlit. DIN-rail: 4 modules, 72 mm width. Operating temperature: -25 to +70 C. Certifications: CE, MID, RoHS. KITOZER warranty: 3 years.
Application Scenarios
Typical deployments include data center PDU sub-metering, tenant energy billing in colocation facilities, factory production line energy allocation, building management system integration, and UPS input output monitoring. In a colocation data center, each tenant PDU has a KITOZER module, and the platform automatically generates monthly energy bills. In a factory, modules on each production line provide departmental energy allocation for cost accounting.
Advantages and Features
The module combines revenue-grade energy accuracy with rich power quality measurements in a DIN-rail package. The built-in Ethernet eliminates the need for a separate gateway, and the web configuration interface reduces commissioning time. Modbus TCP and RTU simultaneously allow integration with both IP-based BMS and serial-based PLC systems. The MID certification supports tenant billing, which is a common requirement in colocation facilities.
Installation and Maintenance Advice
Mount the module on a DIN rail in the distribution panel, connect voltage inputs through fuses, and wire CT outputs with correct polarity. Set the CT ratio and voltage reference through the web interface during commissioning. Verify energy reading against a clamp meter after installation. Update firmware annually through the web interface, and back up configuration files. Inspect CT connections every 2 years for tightness, as loose CT secondary connections can cause measurement errors or dangerous open-circuit voltage.
Typical Deployment Configuration
In a colocation data center, each tenant PDU is fitted with a KITOZER three-phase power monitoring module. Split-core CTs are installed on each phase, and the module publishes voltage, current, power factor, and energy over Modbus TCP to the central DCIM platform. The platform automatically calculates tenant energy consumption and generates monthly billing reports, eliminating manual meter reading. In a factory, modules on each production line provide departmental energy allocation for cost accounting, and the harmonic measurement function detects when VFD or UPS loads are causing excessive current distortion. The MID certification supports legal for trade billing, which is required in many jurisdictions for tenant invoicing. The web configuration interface allows electricians to set CT ratios, tariff schedules, and alarm thresholds without proprietary software, and the LCD display provides local reading for troubleshooting. KITOZER offers a free register map document that simplifies integration with any BMS or SCADA platform, and engineering support is available for first-time commissioning. The module also supports demand response programming, allowing utility-controlled load shedding to be scheduled automatically, and the LCD display can be configured to show customer-specific parameters such as kVA demand or per-phase current. A built-in data logger stores 60 days of interval data locally, so short-term outages do not interrupt energy recording.
Price
From $165 per module, CTs sold separately. Contact +86 13922289957 for panel bundle pricing.