KITOZER
KITOZER

KITOZER Smoke Detector Photoelectric Relay Output For Server Room

The KITOZER photoelectric smoke detector is an aspirating-free, point-type smoke sensor designed for server rooms, data centers, electrical cabinets, warehouses, and office spaces where early fire warning is required without triggering building fire suppression prematurely. It uses an optical chamber with an infrared LED and a photodiode that detects smoke particles scattering light. Compared to ionization detectors, photoelectric sensors respond faster to smoldering fires that produce visible smoke, which are common in electrical overheating scenarios inside server cabinets.

The detector provides a relay output that can connect directly to a KITOZER monitoring host or a conventional fire alarm panel. The relay is normally open and closes when smoke is detected, allowing facility teams to trigger local sounders, camera snapshots, or ventilation shutdown before the building fire department is notified. A remote test input allows maintenance staff to verify detector operation without using an aerosol test spray, reducing the cost of quarterly testing.

Product Overview

The detector is a compact circular unit with a removable base, designed for ceiling mounting. The base carries screw terminals for power, relay output, and remote test. The detector head includes an LED that blinks green during normal operation and turns red steady during alarm. A dust cover protects the optical chamber during construction and is removed before system commissioning.

Technical Specifications

Detector type: photoelectric optical chamber. Sensitivity: 0.10 to 0.15 dB/m obscuration. Power: 12 to 24 VDC, 15 mA typical, 30 mA in alarm. Relay output: 1 x SPDT, 1 A 30 VDC, alarm closes. Remote test input: momentary contact. LED indicator: green normal, red alarm. Operating temperature: -10 to +50 C. Humidity: 95 percent non-condensing. Enclosure: ABS plastic, IP30. Mounting: ceiling, standard 120 mm base. Certifications: CE, EN 14604, RoHS. KITOZER warranty: 3 years.

Application Scenarios

Typical uses include server room ceiling mounting, electrical switchgear rooms, battery rooms, archive storage, retail stock rooms, and hotel back-of-house areas. In a data center, detectors are spaced every 60 to 90 square meters according to local fire code, and each detector relay feeds into the KITOZER monitoring host so that smoke events trigger immediate camera snapshots and phone calls to on-call staff. In a battery room, the early smoke warning catches overheating batteries before thermal runaway.

Advantages and Features

The detector combines photoelectric sensitivity with a clean relay output that integrates easily into non-fire-alarm monitoring systems. Unlike addressable smoke detectors that require a costly loop panel, this unit works with any dry contact input. The remote test input reduces quarterly testing cost. The optical chamber is designed to resist false alarms from dust, insects, and airflow, which is important in data centers where regular air changes can otherwise cause nuisance alarms.

Installation and Maintenance Advice

Mount detectors on the ceiling at least 50 cm from walls and beams, and avoid locations directly above supply air diffusers. Use the remote test input quarterly to verify alarm operation, and clean the optical chamber annually with compressed air. Replace the detector head every 10 years, as the optical LED ages and sensitivity drifts. Keep spare detectors on site so a failed unit can be swapped within hours rather than days.

Typical Deployment Configuration

In a data center server room, KITOZER photoelectric smoke detectors are ceiling mounted every 60 to 90 square meters, spaced according to local fire code. Each detector relay wires to a KITOZER monitoring host dry contact input, and the host maps the alarm to a specific location on the floor plan. When smoke is detected, the host triggers immediate camera snapshots from nearby IP cameras, sends an SMS to the on-call engineer, and records the event in the alarm log for later investigation. Unlike conventional fire alarm panels that require a licensed fire alarm contractor to program, this relay-based integration can be configured by the facility team with no special certification. In a battery room, smoke detectors are spaced closer together because early detection of overheating batteries is critical. The remote test input on each detector allows maintenance staff to verify operation quarterly without climbing a ladder with aerosol test spray, reducing testing time from hours to minutes. KITOZER recommends keeping a spare detector head on site so that any unit showing trouble can be swapped within the same maintenance visit, and provides a 10-year replacement schedule to ensure optical chambers do not age beyond reliable operation. The detector is compatible with both new installations and retrofits, and its standard base format fits most existing ceiling mounting boxes. It draws less than 15 mA in standby, so a single 24 VDC power supply can feed up to 20 detectors on one circuit.

Price

From $22 per unit. Contact +86 13922289957 for project pricing and bulk orders.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top