Table of Contents
ToggleProduct Overview
The KITOZER 10 MHz low pass signal EMI filter protects analog sensor lines, instrumentation wires, and low frequency communication circuits from radio frequency interference and conducted noise without attenuating the wanted measurement bandwidth. It uses a balanced RLC topology that passes the desired signal below the cutoff while shunting high frequency common mode noise to chassis ground. This design preserves the integrity of millivolt level transducer signals that would otherwise be corrupted by nearby switching equipment, motor drives, and radio transmitters.
Technical Specifications
Cutoff frequency 10 MHz low pass, differential mode pass band flat to 10 MHz, characteristic impedance 100 ohms balanced. Insertion attenuation greater than 60 dB from 30 MHz to 1 GHz. Signal current up to 100 mA per line, isolation voltage 500 volts between line and ground. Operating temperature minus 40 to plus 85 degrees Celsius. Compact shielded metal block with screw terminals, CE certified, suitable for analog 4 to 20 mA, 0 to 10 volt, and RS485 physical layer wiring.
Applications
Install this filter on the output of pressure, temperature, and load cell transmitters in factories with high frequency welders and induction heaters. It is also used on medical patient monitor leads, audio microphone lines, and security camera analog outputs where radio frequency ingress causes humming, buzzing, or measurement drift. Engineers add it at the cabinet entry to suppress noise picked up by long field cables running near variable speed drives.
Advantages and Features
The balanced topology ensures that common mode noise is rejected equally on both conductors, preserving the common mode rejection ratio of the analog front end. The shielded metal block provides 360 degree cable entry when used with appropriate EMI cable glands, preventing the filter itself from becoming a radiating source. Low insertion loss in the pass band means signal conditioning accuracy is not compromised, and the through-line current rating accommodates loop powered transmitters without an external supply.
Installation and Maintenance
Mount the filter at the equipment end of the shielded cable and bond the cable shield to the filter chassis with a 360 degree gland rather than a pigtail. Keep the filtered and unfiltered sides separated inside the enclosure. Verify signal bandwidth with a pulse or frequency test before production. No maintenance is required beyond periodic terminal checks; replace the module if attenuation is compromised.
Price
From $12 per piece. Contact plus 86 13922289957 for pricing.