Table of Contents
ToggleProduct Overview
The KITOZER 100 kW shell-and-tube water-cooled condenser is a pressure vessel designed to reject heat from refrigerant circuits to a circulating water loop. It is typically paired with a cooling tower, groundwater well, or closed-circuit cooler in central plant applications. Copper tubes mounted inside a steel shell provide high heat-transfer efficiency and easy mechanical cleaning. The condenser is supplied with refrigerant inlet and outlet flanges, water inlet and outlet flanges, safety relief valve, and sight glass.
Technical Specifications
Nominal heat rejection is 100 kW at 32 degree Celsius condensing temperature and 30 degree Celsius entering water. Water flow is 21 liters per second. Water pressure drop is 40 kPa. Refrigerant side design pressure is 3.0 MPa. Water side design pressure is 1.0 MPa. Connection sizes are 3 inch water flanges and 2-5/8 inch refrigerant weld ends. The shell is carbon steel with internal anti-corrosion coating. Tubes are 0.5 mm thick copper. Dimensions are 1800 mm long by 400 mm diameter. Weight is 220 kg dry.
Application Scenarios
This condenser is used in central chiller plants, industrial process refrigeration, marine HVAC, and district cooling stations. It is preferred where outdoor space for air-cooled condensers is unavailable, or where cooling tower water is already distributed. It is also used in high-rise buildings where rooftop loading is limited. The unit is equally suited to supermarket refrigeration racks, ice rinks, and breweries.
Advantages and Features
Water-cooled condensers achieve smaller condensing temperature differential than air-cooled units, raising chiller efficiency by 10 to 20 percent. Shell-and-tube construction is robust and serviceable: tubes can be mechanically rodded or chemically cleaned without removing the shell. The unit is rated for continuous 24/7 operation. A high-pressure safety relief valve and refrigerant sight glass aid commissioning and maintenance. The shell is pressure-tested before shipment. The unit also supports a remote pressure gauge and a water temperature sensor, so operators can monitor performance without climbing into the mechanical room. A built-in sight glass allows quick visual inspection of refrigerant liquid level during commissioning.
Installation and Maintenance Recommendations
Mount the condenser on a steel frame with vibration isolators. Install Y-strainers on the water inlet. Treat cooling tower water to prevent fouling and biological growth. Inspect tube wall thickness every three years via eddy-current test. Clean tubes annually if water quality is poor. Verify relief valve calibration every five years. Commissioning should include a water pressure test and a refrigerant side pressure test. A remote pressure gauge can be installed at the condenser for continuous monitoring, so operators can spot rising pressure before it triggers a shutdown. Operators should be trained on water balancing, strainer cleaning, and the procedure for isolating the condenser for tube cleaning without draining the entire loop.
Energy and Environmental Performance
Because the condenser operates at a lower condensing temperature than an air-cooled equivalent, the compressor uses less electricity for the same cooling load. Over a year, this efficiency gain can offset the cost of the cooling tower and pumping system. The shell and tubes are fully recyclable at end of life. No refrigerants are used in the water loop. Over a year, the efficiency gain from lower condensing temperature can offset the cost of the cooling tower and pumping system. The shell and tubes are fully recyclable at end of life, with copper tubes and steel shell separated for scrap.
Configuration Options and Warranty
The condenser is offered in multiple heat-rejection sizes and with either copper cupronickel tubes for seawater service or standard copper tubes for freshwater. Optional extras include a sight glass, a relief valve, and a mounting frame. The standard warranty covers the shell and tubes for 2 years, with extended coverage up to 5 years available. A preventive maintenance package with annual tube inspection and relief valve calibration is available for central plant deployments.
Price
From $2,680 per unit. Contact plus 86 13922289957 for shell-and-tube condenser pricing and selection.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com