Table of Contents
ToggleProduct Overview
The KITOZER eight door enterprise access controller is a high capacity networked access control panel designed for medium to large buildings such as corporate headquarters, hospitals, universities, shopping malls, and government offices. A single panel manages eight door zones with up to sixteen Wiegand readers, supporting a mix of proximity, Mifare, keypad, and biometric readers across different entrances. The controller stores up to 200,000 card records and one million event transactions in industrial grade flash memory, enough to sustain a campus sized deployment without a local database. Dual Ethernet ports allow the panel to connect to two physically separated networks for redundancy, and an optional 4G module provides failover communication when the wired LAN is disrupted. The panel integrates directly with the KITOZER professional access management platform, which supports badge issuance, visitor registration, elevator floor control, parking barrier linkage, and anti tailgating analytics.
Technical Specifications
The controller board is 280 mm by 180 mm by 30 mm and requires 12 V DC at 2.5 A, with a recommended 12 V 10 A power supply and 12 V 12 Ah battery for eight hour standby. Two 10 100 Mbps Ethernet ports support TCP IP, DHCP, and static routing. Up to sixteen Wiegand ports accept 26, 34, and 66 bit protocols at 120 meter cable length. Eight supervised lock relay outputs are rated 30 V DC 3 A each. Sixteen supervised inputs monitor exit buttons, door contacts, glass breaks, fire triggers, and auxiliary alarms. The panel supports RS485 expansion for elevator control modules and guard tour readers, and an optional Wiegand to OSDP converter allows encrypted reader communication. Operating temperature is minus 20 to 60 degrees Celsius. Built in functions include anti pass back, interlock, duress, multi card opening, first card unlock, holiday schedules, and time based group access. Security features include 128 bit AES communication encryption, SSL for web management, and a tamper switch that triggers an alarm when the enclosure is opened.
Application Scenarios
This eight door panel is typically deployed as the main access controller for an entire building wing. In a hospital, it covers the main entrance, emergency department door, maternity ward, pharmacy, ICU corridor, laboratory, staff locker room, and IT equipment room. In a university, it secures the library entry, faculty offices, research labs, server room, and dormitory common areas. In a shopping mall, it controls the staff corridor, back of house delivery door, customer service office, and rooftop mechanical room. Because the panel supports elevator floor control via RS485 expansion, it can also restrict which floors an employee badge may reach inside the lift, a common requirement for corporate offices and luxury hotels. Visitors can be issued temporary QR code or NFC credentials from the reception desk, which expire automatically after the scheduled appointment window.
Advantages and Features
The key advantage of the eight door controller is consolidation. One panel, one Ethernet drop, and one power supply replace eight separate controllers, which reduces cabinet space, simplifies troubleshooting, and lowers total cost of ownership. The dual Ethernet design provides network redundancy, a critical feature for mission critical buildings where a single switch failure must not lock down all entrances. The professional software platform offers role based access control for security staff, human resources, and building managers, with separate audit trails for each operator. Event data can be forwarded to a third party VMS, building management system, or security information event management platform through REST API and Modbus TCP. The panel also supports card anti pass back across multiple doors, so an employee cannot tailgate a colleague by passing the badge back through a reader. CE, FCC, and ISO 9001 manufacturing standards back the hardware, and the KITOZER two year warranty covers board replacement.
Installation and Maintenance Advice
Install the panel in a locked IT or security closet with temperature controlled ventilation. Use shielded FTP cable for the Ethernet drop and route reader cables away from fluorescent ballasts and variable frequency drives. Label every reader, lock, and input on the enclosure door with a reference table matching the as built drawing. When commissioning, first configure the network settings and verify that the panel appears online in the management software, then wire and test each door one at a time. Set the fire alarm release logic so that all doors unlock on fire panel signal, except high security cages that require manual override. Perform a monthly backup of the card database and event log, and test the battery under load every six months. Firmware upgrades should be scheduled during off hours, and a backup panel should be kept on site for large campus projects to minimize downtime in case of board failure.
Price
From $320 per piece. Contact KITOZER for campus project pricing and lead time.