KITOZER
KITOZER

KITOZER Copper Grounding Tape 25x4mm Bare Braided For Bonding

Product Overview

KITOZER copper grounding tape 25x4mm is a flat bare copper conductor used to connect switchgear enclosures, cable tray segments, lightning air-terminal down conductors, and equipment frames to the main earthing system. Manufactured from soft-annealed copper wires braided and hot-pressed into a flat strip, the tape retains the flexibility of a cable while presenting a wide contact surface for bolted lugs or exothermic welds. The 25mm width by 4mm thickness provides cross-section equivalent to a 70mm2 round cable but with much lower inductance, which is critical for high-frequency lightning current dispersion. KITOZER supplies bare tape for buried or indoor use, and tinned tape for coastal, humid, or corrosive environments.

Technical Specifications

Material: annealed copper strands, conductivity 97% IACS minimum. Cross section: 25mm width by 4mm thickness, equivalent copper area about 75mm2. Standard coil: 50m or 100m. Surface: bare or electro-tin 8 microns. DC resistance at 20C: not more than 0.25 milliohm per meter. Rated impulse current per IEC 62561-2: 100 kA (10/350 microsecond). Continuous current rating: 120 A at 40C ambient. Minimum bending radius: 12 times tape width. Operating temperature: minus 40C to plus 200C. Connection options: bolted lug, exothermic weld, compression clamp. Certifications: ISO 9001, IEC 62561-2, RoHS. Brand: KITOZER. Warranty: 15 years bare, 25 years tinned.

Application Scenarios

This copper tape is the standard bonding jumper in lightning protection down-conductor systems, roof air-terminal networks, and facade metal trim equipotential rings. It runs around the perimeter of data centers to form the equipotential bonding network, connects cable trays between building sections, and bonds bus duct enclosures to the PE bar. In substations, it links transformer neutral points to the earth grid with very short lead length. In solar farms, it bonds rack frames across modules to prevent lightning-induced arc damage. In explosion-proof zones, it ensures continuity between flanged pipes and valves. The tape is also widely used as the flexible bond between moving equipment, crane rails, and rotating machinery frames where rigid bars cannot tolerate vibration.

Advantages and Features

The flat geometry of KITOZER copper tape gives lower inductance than round cable of equal cross-section, improving high-frequency lightning current sharing. The braided construction tolerates repeated bending without strand breakage, making it ideal for vibrating installations and sliding contacts. The wide face distributes bolt pressure evenly, reducing contact resistance and preventing cold weld loosening. Tinned version resists atmospheric corrosion in coastal and industrial acid rain environments. KITOZER tape is supplied on plastic reels for clean site handling, and can be pre-cut with formed lugs to reduce field work. Compared with round copper wire, flat tape occupies less vertical space in tray edges and behind switchgear panels.

Installation and Maintenance Recommendations

Fix the tape with UV-resistant cleats at 500mm spacing on indoor runs and 800mm spacing on outdoor runs. Do not exceed the minimum bend radius of 300mm to avoid kinking. For bolted connections, use flat and spring washers, apply antioxidant grease, and torque to 18 Nm for M10 lugs. For exothermic welded joints, grind the tape face bright before welding and inspect the weld bead for complete fusion. When routing outdoors, avoid contact with lime mortar and use UV-stabilized tie wraps. Inspect joints annually for oxidation, and measure bonding continuity with a micro-ohmmeter; a rise above 10% of baseline indicates joint degradation. In coastal sites, flush tape with fresh water every two years to remove salt residue. KITOZER supplies installation clamps, weld molds, and test documentation templates.

Price

From $12.5 per meter bare, $15.8 per meter tinned. Contact +86 13922289957 for coil pricing and project discount.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top