KITOZER
KITOZER

KITOZER KTR-OSC-10 Coalescing Oil Separator (Compressed Air Oil/Water Removal)

KITOZER KTR-OSC-10 Coalescing Oil Separator (Compressed Air Oil/Water Removal)

Brand: KITOZER Series: KTR-OSC-10 Category: Oil Separator / Compressed Air Treatment

coalescing1.0 MPa10 m3/minoil 0.01 mg/m3KTR-OSC-10

1. Overview

The KITOZER KTR-OSC-10 is a coalescing oil separator installed in compressed-air lines to remove oil mist, water, solid particles and gaseous oil vapour. Air-compressor discharge air is hot, oil-laden and wet; feeding it directly to pneumatic equipment ages cylinder seals, jams solenoid valves, causes paint defects, and contaminates food and pharma packaging. KTR-OSC-10 is installed after the receiver tank and before point-of-use, delivering clean air meeting ISO 8573-1.

KTR-OSC-10 uses the coalescing principle: multi-layer micro-glass-fibre media intercepts 0.1 to 1 micron oil aerosols and coalesces them into large droplets that drain by gravity into a bottom bowl, ejected by a timed float auto-drain; a downstream activated-carbon element can be added to adsorb gaseous oil vapour and hydrocarbons. Die-cast aluminium housing with epoxy coating, 1.0 MPa design pressure, 10 m3/min rated flow, G1/2\” female port, a top differential-pressure gauge (electric contact alarm at 0.07 MPa clogging), and a bottom auto-drain cycling 30 s open / 3 min closed.

Typical uses: powder/paint lines (oil-free air to avoid pinholes and fish-eye); SMT electronics (moisture causes cold solder and nozzle clogging); pneumatic cylinders and valves (oil removal doubles-to-triples seal life); food packaging and pharma (ISO 8573-1 Class 1.2.1); lab GC carrier-gas pre-filtration. KTR-OSC-10 cuts downstream unplanned downtime.

2. Key Features

Coalescing filtration

  • Multi-layer micro glass-fibre media.
  • Outlet oil carry-over 0.01 mg/m3.
  • 0.01 micron rating.
  • Particulate to ISO Class 1.

Housing & drain

  • Die-cast aluminium housing.
  • 1.0 MPa design pressure.
  • Float-style auto drain.
  • DP gauge monitors clogging.

Flow & ports

  • Rated flow 10 m3/min.
  • G1/2\” female port.
  • Working temp 5 to 66 C.
  • New-element DP 0.02 MPa.

Install & service

  • Vertical or horizontal line.
  • Mounting bracket included.
  • Transparent drain bowl.
  • Quick-change element.

3. Specifications

Item Parameter
Model KTR-OSC-10
Principle Coalescing + activated carbon adsorption
Rated flow 10 m3/min (1.0 MPa inlet)
Working pressure 0.4 to 1.0 MPa
Inlet oil 5 mg/m3 (injected screw)
Outlet oil 0.01 mg/m3 (coalescing stage)
Rating 0.01 micron
Particulate 0.1 mg/m3 (ISO Class 1)
Port G1/2\” female
DP alarm 0.07 MPa (electric contact)
Drain Float auto drain
Working temp 5 to 66 C
Housing Die-cast aluminium, epoxy coated
Dimensions about 180x120x320 mm

4. Reference Prices

KTR-OSC-10 coalescing stage (0.01 mg/m3 oil): Ref. USD 95~136 / pc (CNY 680~980 at 7.2)

KTR-OSC-10 activated-carbon stage (oil vapour): Ref. USD 72~106 / pc (CNY 520~760 at 7.2)

KTR-OSC-100 two-stage combo (coalescing+carbon): Ref. USD 153~222 / set (CNY 1100~1600 at 7.2)

Replacement coalescing element: Ref. USD 25~36 / pc (CNY 180~260 at 7.2)

Replacement carbon element: Ref. USD 17~25 / pc (CNY 120~180 at 7.2)

Auto-drain spare: Ref. USD 5~8 / pc (CNY 35~60 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Powder/paint line air prep.
  • SMT shop compressed air.
  • Pneumatic cylinder oil removal.
  • Food/pharma clean air.
  • GC carrier-gas pre-filter.

6. Installation & Maintenance

Installation

  • Vertical or horizontal; flow matches the housing arrow.
  • Install after receiver and after the dryer (dryer removes bulk water first).
  • Inlet upstream, outlet downstream, drain bowl facing down.
  • Mount near point of use (closer is better).
  • Isolation ball valves before/after for element change.
  • Wire DP gauge across inlet and outlet.
  • Route drain hose to an oil-water collector (oily condensate is hazardous).
  • Blow the line 5 minutes before feeding equipment.

Maintenance

  • Read the DP gauge monthly; change at 0.07 MPa.
  • Check the drain weekly; manually drain if stuck.
  • Coalescing element every 2000 to 4000 h.
  • Carbon element every 1000 h or 6 months (adsorption irreversible).
  • Never back-blow the element (glass fibre breaks).
  • Heating tape below 5 C to prevent freeze.

7. FAQ

  • Q:Coalescing vs adsorbing?
    A:Coalescing (KTR-OSC-10) uses glass fibre to trap liquid oil mist and water droplets (0.01 mg/m3) but cannot remove gaseous oil vapour. Activated carbon adsorbs gaseous hydrocarbons and removes oil smell but cannot remove liquid water. Paint and food need two stages: coalesce liquid first, then carbon for vapour. Coalescing alone leaves a faint oily smell; carbon alone breaks through quickly when liquid oil hits it.
  • Q:Why is compressed air suddenly oily?
    A:Injected screw compressor discharge is 30 to 50 mg/m3 oil; the internal air-oil separator ages after 8000 h and carry-over jumps above 200 mg/m3. Check the compressor’s internal separator element first (does it need replacing?), then the downstream filter. If the KTR-OSC-10 element blacks out in 3 days, the compressor itself is over-oiling; fix the compressor first.
  • Q:Must I change the element at DP alarm?
    A:Yes. New-element DP is 0.01 to 0.02 MPa; at 0.07 MPa the media is heavily fouled, pressure drops (point-of-use loses 1 bar), and coalescing efficiency falls (oil droplets punch through). Do not wait for rupture; keep a spare. Continuous-duty plants pre-change every 4000 h.
  • Q:Is constant dripping normal?
    A:Yes. Compressed air yields litres to tens of litres of condensate daily (depending on humidity and compressor kW); the drain cycles 30 s open / 3 min closed. If it flows continuously without closing, the float is stuck (debris); flush the float valve. If it never drains and the bowl fills, check solenoid power and strainer.

8. Trend & Selection

Compressed-air treatment moves from single-stage to multi-stage (pre-filter + dryer + coalescing + carbon + sterile). Dew-point and particle counters network into energy management. Oil-free compressors (dry screw, centrifugal) gain share but still need downstream filtration for ISO Class 1. Elements move to traceable RFID (record replacement cycles) and low pressure drop (5% energy saving). Food/pharma mandates sterile filtration (0.01 micron hydrophobic PTFE).

9. Delivery & Service

KITOZER sizes KTR-OSC-10 by point-of-use flow and oil requirement, providing flow-DP curves, ISO 8573-1 class maps and element replacement schedules. Delivery includes separator, auto drain, DP gauge, bracket, gaskets and certificate. Warranty covers element cross-reference and installation guidance.

10. Additional Notes

A common pitfall is installing the separator before the dryer. The dryer needs inlet air below 45 C; hot (80 C) wet air kills dryer efficiency. Correct order: compressor -> receiver -> pre-filter (bulk water) -> dryer (cool/remove water) -> coalescing (KTR-OSC-10) -> carbon -> point of use.

Another pitfall is never changing the carbon element. Once saturated, carbon releases previously adsorbed oil vapour (re-contamination), making air smell worse. Replace carbon every 6 months regardless of the DP gauge.

Selection summary: coalescing oil removal; 10 m3/min; 1.0 MPa; 0.01 micron; auto drain. The oil separator is the gatekeeper of compressed-air quality; the keys are installing after the dryer, changing elements on time, and treating oily condensate as hazardous waste.

Additional tip: drained oily condensate is hazardous waste; do not pour it down the drain. Small plants use an oil-water separator to skim free oil; send wastewater to a licensed hauler. KITOZER offers an optional small oil-water separation bowl.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top