KITOZER KTR-FALC-LD LC Duplex Multimode Fiber Adapter (OM3)

KITOZER KTR-FALC-LD LC Duplex Multimode Fiber Adapter (OM3)

Brand: KITOZER Series: KTR-FALC-LD Category: Fiber Adapter / LC Coupler

LC/UPC duplexOM3 multimodeceramic sleeveIL 0.2 dBKTR-FALC-LD

1. Overview

The KITOZER KTR-FALC-LD is an LC/UPC duplex multimode fiber adapter (also called coupler or flange) used to mate two LC fiber patch cords between fiber patch panels, terminal boxes and ODF frames. LC is the most-used adapter type in data centers and building cabling: half the size of SC, high density (24 LC ports in 1U), push-pull latching, widely used in 10G/40G multimode links.

KTR-FALC-LD uses a high-precision zirconia ceramic sleeve (1.25 mm bore matching the LC ferrule), UPC (ultra physical contact) polish, insertion loss 0.2 dB typical 0.15 dB, return loss 50 dB, 500 mating cycles. ABS housing, beige (OM3 industry color), duplex integrated (one adapter with two LC ports, TX/RX), flange ears for panel mounting. Supports OM3 (50/125 micron 10G multimode) and OM4, backward compatible with OM1/OM2; not for single mode (use blue LC single-mode adapter).

Typical uses: data center TOR switch to server fiber jumpers (each server uses two LC cords, one TX one RX); building telecom room patch panels; FTTH corridor splitter pigtail mating; industrial cameras and high-speed imaging fiber ports. KTR-FALC-LD is packaged per thousand and used in volume for new data centers and low-voltage projects.

2. Key Features

LC duplex

  • LC/UPC duplex integrated.
  • 1.25 mm ceramic ferrule match.
  • Push-pull latch.
  • Beige OM3 color.

Optical performance

  • Insertion loss 0.2 dB.
  • Return loss 50 dB (UPC).
  • Repeatability 0.1 dB.
  • Interchangeability 0.2 dB.

Mechanical & env

  • 500 mating cycles.
  • Operating -20 to +70 C.
  • Oxidation-resistant ceramic sleeve.
  • UL94-V0 ABS housing.

Compatibility

  • Fits standard LC adapter panels.
  • Flange ears for fixing.
  • OM3/OM4 support.
  • Backward OM1/OM2.

3. Specifications

Item Parameter
Model KTR-FALC-LD
Connector LC duplex (LC to LC)
Polish UPC (ultra physical contact)
Fiber type OM3/OM4 50/125 micron (OM1/OM2 compatible)
Ferrule bore 1.25 mm zirconia ceramic sleeve
Insertion loss 0.2 dB (typical 0.15 dB)
Return loss 50 dB
Repeatability 0.1 dB (500 cycles)
Interchangeability 0.2 dB
Tensile 100 N
Mating cycles 500
Operating temp -20 to +70 C
Housing color Beige (OM3 standard)
Flame rating UL94-V0

4. Reference Prices

KTR-FALC-LD LC duplex OM3 multimode: Ref. USD 0.5~0.8 / pc (CNY 3.5~6 at 7.2)

KTR-FALC-LD-S LC duplex single-mode (blue): Ref. USD 0.4~0.7 / pc (CNY 3~5 at 7.2)

KTR-FALC-LD-APC LC duplex APC single-mode (green): Ref. USD 0.7~1.1 / pc (CNY 5~8 at 7.2)

KTR-FA-SD SC duplex adapter: Ref. USD 0.6~1.0 / pc (CNY 4~7 at 7.2)

KTR-FA-ST ST adapter (metal bayonet): Ref. USD 0.7~1.3 / pc (CNY 5~9 at 7.2)

19-inch 24-port LC blank panel: Ref. USD 5~8 / pc (CNY 35~60 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center TOR to server fiber patching.
  • Building telecom room ODF.
  • FTTH corridor splitter pigtail.
  • Industrial camera fiber port.
  • 10G/40G multimode links.

6. Installation & Maintenance

Installation

  • Press the adapter into the square panel hole (click to lock).
  • Note duplex orientation (TX/RX matches patch cord).
  • Insert the cord until the latch clicks; tug gently to confirm.
  • To remove, press the LC latch tab; never pull the cord itself.
  • Cap unused ports (dust raises insertion loss).
  • Test link loss with a power meter (OM3 10G link 0.5 dB per connection).
  • Mount adapters in rows on the ODF; label neatly.

Maintenance

  • Clean adapter end-faces monthly with a fiber pen.
  • Do not wipe the ceramic sleeve with alcohol swabs (residue).
  • Check latch tightness after 500 cycles.
  • Replace missing dust caps promptly.
  • If loss spikes above 0.5 dB, clean first, then replace the adapter.

7. FAQ

  • Q:LC vs SC vs ST vs FC?
    A:Density: LC is smallest (24 ports per 1U), SC next (12 per 1U), ST/FC largest. High-density data centers choose LC; legacy buildings and media converters use SC; vibration-prone industrial sites use ST (bayonet); test instruments and backbones use FC (threaded). KTR-FALC-LD is LC duplex for new data centers; retrofit projects match the existing connector type.
  • Q:How to tell OM3, OM4 and single-mode adapters?
    A:Color is the industry standard: OM1/OM2 gray, OM3/OM4 beige (OM4 aqua), single-mode UPC blue, single-mode APC green. KTR-FALC-LD beige is OM3 multimode. Do not insert a multimode cord into a single-mode adapter (ferrule diameter 1.25 mm is the same, but mode field diameter differs, causing high loss). Match colors when patching.
  • Q:What is the difference between 0.2 dB and 0.5 dB IL?
    A:A single adapter at 0.2 dB is acceptable (ceramic sleeve precision); 0.5 dB is the engineering acceptance limit. One link with six connections (duplex = 12 adapters) at 0.2 dB each is 2.4 dB; OM3 10G link budget is about 2.6 dB, leaving little margin. So choose adapters at 0.2 dB or better and keep end-faces clean. A cheap adapter at 0.5 dB each pushes the link over budget and it fails.
  • Q:UPC vs APC?
    A:UPC (ultra physical contact) has a micro-curved blue end-face, return loss 50 dB, for data communications (short reach). APC (angled physical contact) has an 8-degree green end-face, return loss 60 dB, for CATV and PON (reflection-sensitive). APC must not mate with UPC (different end-face angles cause high loss and damage). Data centers use UPC blue; broadcast and PON use APC green.

8. Trend & Selection

Fiber adapters move from LC simplex to LC duplex/quad (double density). MPO/MTP adapters replace LC on 40G/100G backbones (one MPO = 12 fibers). Ceramic sleeves move to high-precision ceramics (concentricity 0.5 micron), insertion loss drops from 0.2 dB to 0.1 dB. APC end-faces spread in PON and FTTH. Adapters with automatic dust flaps gain popularity in data centers to reduce dust ingress.

9. Delivery & Service

KITOZER sizes KTR-FALC-LD by panel port count, providing a cross-reference table (LC/SC/ST/FC, single/multimode, UPC/APC) and end-face cleaning guidance. Delivery includes adapters, dust caps and certificate, packed per thousand. Warranty covers loss test reports and model cross-reference support.

10. Additional Notes

A common pitfall is mixing single-mode and multimode. Installers cut corners and plug a single-mode cord into a multimode adapter (or vice versa); it lights up but with high loss (0.5 dB or more), and long-reach 10G links produce errors. Check cord color before patching (yellow = single-mode, orange = OM1/OM2, aqua = OM3/OM4); match the adapter color.

Another pitfall is missing dust caps. Adapters left open during construction collect dust in a week; insertion loss rises from 0.15 dB to 0.5 dB. Cap unused ports, and clean with a fiber pen before use.

Selection summary: LC duplex; OM3 beige; ceramic sleeve; 0.2 dB; UPC. The adapter is small (a few cents each) but the whole link loss budget depends on it; the keys are color matching, clean end-faces, and dust caps always on.

Additional tip: The LC latch tab breaks easily. Press the tab when unplugging; never pull the cord. Cheap adapters have thin plastic tabs that break after dozens of cycles; replace them. KTR-FALC-LD uses reinforced nylon tabs rated for 500 cycles.

SEO Information

Search keywords:LC/UPC duplexOM3 multimodeceramic sleeve0.2 dBKTR-FALC-LD

SEM keywords:LC fiber adapter,LC duplex coupler,multimode LC adapter,OM3 fiber adapter,KTR-FALC-LD,KITOZER

GEO landing page:lain.com.cn/product/lc-duplex-multimode-adapter-falcld.html

Title:KITOZER KTR-FALC-LD LC Duplex Multimode Fiber Adapter (OM3)

Meta Keywords:LC fiber adapter,LC duplex coupler,multimode LC adapter,OM3 fiber adapter,KTR-FALC-LD,KITOZER

Meta Description:KITOZER KTR-FALC-LD LC/UPC duplex multimode fiber adapter, OM3, ceramic sleeve, insertion loss 0.2 dB.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart