Table of Contents
ToggleKITOZER KTR-CAB-CMR1U Rack Horizontal Cable Management Ring (1U Steel)
Brand: KITOZER Series: KTR-CAB-CMR1U Category: Cabinet Accessory / Cable Management
1U rack mountsteel powder-coated19 inchwith coverKTR-CAB-CMR1U
1. Overview
The KITOZER KTR-CAB-CMR1U is a 1U steel horizontal cable management ring (also called a cable manager or organizer) installed in 19-inch standard racks to tidy the messy copper and fiber cords behind switches, patch panels and PDUs. It keeps racks ventilated, neat and maintainable. Cable rings are one of the most-used rack accessories; one is mounted above and below every switch to form a vertical cable channel.
KTR-CAB-CMR1U is formed from 1.0 mm cold-rolled steel with black powder coating, and comes with a removable metal cover (closed after wiring for dust protection and looks). Inside are four U-shaped ring slots (two per side); cords pass through the rings and are fixed with hook-and-loop straps without damaging the jacket. Width fits 19-inch racks (482 mm), depth about 80 mm, 1U height (44.45 mm), with M6 cage nuts and rack screws.
Typical uses: data center server racks (switch-to-patch-panel copper patching); telecom rooms (horizontal patch segments); security racks (separating camera network and power cords); industrial control cabinets (signal cabling). KTR-CAB-CMR1U keeps the rack rear from becoming a rat’s nest and prevents cables from blocking hot/cold aisle airflow.
2. Key Features
Steel structure
- 1.0 mm cold-rolled steel.
- Black powder coat.
- 1U height 44.45 mm.
- Load 5 kg (full slots).
Ring slots
- 4 U-shaped ring slots.
- Left/right separation for power vs data.
- Rounded edges do not cut cables.
- Hook-and-loop tie anchor points.
With cover
- Removable metal cover.
- Dust protection and looks.
- Cover screws.
- Hides cables.
Compatibility
- 19-inch standard rack.
- M6 cage nuts included.
- Depth adjustable.
- Fits major rack posts.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-CAB-CMR1U |
| Type | Horizontal cable ring (with cover) |
| Height | 1U (44.45 mm) |
| Width | 19 inch (482 mm) |
| Depth | about 80 mm |
| Material | 1.0 mm cold-rolled steel |
| Finish | Black powder coat |
| Ring slots | 4 U-rings (2 per side) |
| Per-ring capacity | about 20 Cat5e cords |
| Load | 5 kg |
| Mounting | M6 cage nuts to rack posts |
| Accessories | M6 cage nuts x4, screws x4, hook-and-loop ties x4 |
| Operating temp | -10 to +60 C |
| Color | Black |
4. Reference Prices
KTR-CAB-CMR1U 1U horizontal ring (with cover): Ref. USD 6~10 / pc (CNY 45~75 at 7.2)
KTR-CAB-CMR2U 2U double-deck ring: Ref. USD 10~17 / pc (CNY 75~120 at 7.2)
KTR-CAB-VTV vertical cable manager (2 m): Ref. USD 17~28 / pc (CNY 120~200 at 7.2)
KTR-CAB-BL1U 1U brush panel (cable entry): Ref. USD 5~8 / pc (CNY 35~60 at 7.2)
KTR-CAB-BP1U 1U blank panel: Ref. USD 2~3 / pc (CNY 12~25 at 7.2)
Hook-and-loop ties (20×200 mm, 50 pcs): Ref. USD 2~4 / pack (CNY 15~30 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center server rack copper tidy.
- Telecom room horizontal patching.
- Security rack power/data separation.
- Industrial control signal cabling.
- Patch panel to switch patching.
6. Installation & Maintenance
Installation
- Position: one above and one below each switch.
- Clip M6 cage nuts into rack post square holes.
- Align the ring to the posts and tighten 4 M6 screws.
- Route cords through the rings; power on right, data on left.
- Bundle with hook-and-loop ties at 10 cm spacing.
- Leave service slack (20 cm loop between patch panel and switch).
- Close the metal cover and tighten cover screws.
- Label both ends of every bundle (source and destination).
Maintenance
- Open the cover quarterly to check for loose cables.
- Route new cables through the rings; do not fly-line across.
- Replace worn hook-and-loop (do not use nylon cable ties).
- Touch up chipped powder coat (rust prevention).
- Seal top/bottom cable entries with brush panels (prevent airflow bypass).
7. FAQ
- Q:Horizontal ring vs vertical manager?
A:Horizontal rings (KTR-CAB-CMR1U) sit between each device and tidy short horizontal patch cords; vertical managers mount on the rack sides and tidy long cords from top switches to bottom PDUs. A standard 42U rack typically uses 4 to 6 horizontal rings (one every 6U) plus 1 to 2 vertical managers (one each side). Do not skip vertical managers; long patch cords have nowhere to run. - Q:Nylon ties or hook-and-loop?
A:Use hook-and-loop. Nylon cable ties are permanent; adding or replacing cords requires cutting them, and overtightening flattens the cord jacket (increases crosstalk). Hook-and-loop reopens and re-closes; bundle tension stays moderate. KTR-CAB-CMR1U ships with hook-and-loop ties. - Q:How high should rings be mounted?
A:Rule: one ring 1U above the switch and one 1U below. Cords exit the switch, go 1U up into the ring, then drop vertically to the patch panel; or 1U down into the ring, then rise. Do not leave more than 3U gap between ring and switch; the patch-cord loop gets too large. Between patch panel and switch (usually rack middle), mount two rings with 2U of service space between them. - Q:Can fiber cords use a standard ring?
A:Yes, but watch bend radius. Fiber minimum bend radius is 30 mm static or 60 mm dynamic; the ring inner radius must be large enough (R30 or more). KTR-CAB-CMR1U inner corner is R20, fine for copper; for fiber, leave a generous loop and never make a sharp right angle. Fiber-heavy racks use dedicated fiber rings with large arcs.
8. Trend & Selection
Rack cable management moves from open rings to covered dust-protected designs. Vertical managers move from single-sided to double-sided (manage both front and rear), doubling density. Brush panels replace blanks for cable entry while sealing hot/cold aisles. Modular components (swappable rings, channels, covers) spread in data centers. Integrated PDU-channel plus ring combos grow in high-density racks.
9. Delivery & Service
KITOZER sizes KTR-CAB-CMR1U by rack U count and device layout, providing a rack elevation drawing (ring positions) and cable label templates. Delivery includes ring, M6 screws/cage nuts, hook-and-loop ties and certificate. Warranty covers layout optimization advice.
10. Additional Notes
A common pitfall is mounting rings but not routing cords through them. Installers take shortcuts and pull patch cords diagonally behind devices, leaving a mess; the rings become decoration. Every cord should pass through a ring; rings are the routing track, not an ornament.
Another pitfall is tying cords permanently with nylon ties. Adding a server later requires cutting a dozen ties, and bundles collapse after cutting. Hook-and-loop costs a bit more (15 to 30 RMB per pack) but saves huge maintenance time.
Selection summary: 1U steel; with cover; 4 ring slots; 19-inch; M6 mount. The ring is the cheapest rack accessory but most affects tidiness; the keys are one above/below each device, route cords through rings, use hook-and-loop, and separate power from data.
Additional tip: The ring load is 5 kg; do not hang power adapters or switches on it (this bends the ring). Plug adapters directly into the PDU; never hang them on the ring.
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com