KITOZER Micro Module Data Center 20 Racks 200kW Integrated

KITOZER micro module data center is a pre-integrated, factory-tested row of IT racks, containment, cooling, power, and monitoring that ships as a single skid and plugs into a facility. The 20 rack, 200 kW configuration described here is built for enterprise on-premise deployments, colocation buildouts, and industrial edge sites that need capacity in weeks rather than months. The module includes two rows of 10 racks each, a contained cold aisle between them, two in-row precision air conditioners, a UPS row, automatic transfer switches, power distribution units, leak detection, smoke detection, and a central monitoring controller with touchscreen and remote web access. Because all integration is done in the factory, on-site commissioning takes days instead of months.

Product Overview

A micro module replaces the traditional project-by-project data center build with a standardized, repeatable building block. KITOZER engineers size the module for the target load and environment, preassemble every component in the factory, run a full burn-in test, and then ship the module in sections to the site. The customer only needs to provide a level floor, utility power, chilled water or a dry cooler connection, and network links. On site, the sections are bolted together, cables reconnected at quick disconnects, and the module is commissioned within one week. The architecture supports N plus 1 redundancy for power and cooling, and it scales by adding more micro modules in parallel, each with its own containment and monitoring.

Technical Specifications

IT load: 200 kW across 20 racks at 10 kW average. Rack count: 20 x 42U, 600 x 1200 mm. Aisle: 1200 mm cold aisle containment with automatic sliding doors and polycarbonate skylights. Cooling: 3 x 80 kW in-row precision air conditioners, N plus 1, chilled water at 7/12 C, EC fans. Power: 2 x 120 kVA UPS, N plus 1, double conversion, with 15 minutes battery autonomy. PDUs: 20 x 32 A monitored vertical PDUs per rack row. Monitoring: central controller with 15 inch touchscreen, Modbus TCP, SNMP, email alerts, optional 4G remote. Safety: VESDA smoke detection, Vesda pre-action or clean agent suppression interface, leak detection along water lines, emergency power off buttons. Dimensions per module: 12,000 L x 3,000 W x 2,600 H mm. Weight: about 6,500 kg. Operating environment: 10 to 35 C ambient, 20 to 80 percent RH.

Applications

Micro modules are chosen when speed to capacity matters, when building a traditional white space is too slow, or when the customer wants to avoid bespoke engineering. Typical deployments include enterprise on-premise data centers for banks and insurance firms, colocation pods that can be added quarter by quarter, manufacturing edge sites running SCADA and MES, university research computing clusters, and military or government secure facilities. They are also used as temporary capacity during permanent data center construction, and as disaster recovery sites that can be relocated later. The module fits inside a standard warehouse floor with no structural modification, provided floor loading exceeds 1,200 kg per square meter.

Advantages and Features

The principal benefit is speed. Factory integration cuts project schedule from 6 to 12 months to 6 to 10 weeks. A second benefit is predictability: the customer knows exactly what they are buying, because the module is a proven configuration rather than a custom design. Third, PUE is typically 1.3 to 1.5, because containment, in-row cooling, and EC fans are designed together. Fourth, monitoring is built in from day one, so the customer does not need to integrate separate BMS, DCIM, and alarm systems. Fifth, the module can be disassembled and moved if the business changes, which is impossible with a traditional build. Sixth, every component is KITOZER branded and covered by a single warranty, simplifying spare parts and service.

Installation and Maintenance

The module arrives on four flatbed trucks in bolted sections. A four person crew positions the sections with forklift, bolts them together, reconnects quick disconnect water and power couplings, and calibrates the monitoring system. Factory commissioning engineers spend one week on site running thermal, power, and failover tests. Routine maintenance is quarterly: inspect filters, check battery voltages, verify leak sensors, and review alarm logs. Annually, the UPS batteries are load tested, the cooling coils are cleaned, and the fire suppression interface is tested. KITOZER offers a 5 year warranty on the whole module, and spare parts are stocked locally. The monitoring controller sends automatic service tickets when a component needs attention, so the customer does not need a dedicated data center engineer on staff.

Price

From $285,000 per 20 rack, 200 kW micro module, including racks, containment, cooling, UPS, PDUs, and monitoring. Contact +86 13922289957 for a detailed quotation.