KITOZER
KITOZER

KITOZER High Voltage AC Voltage Detector 10kV Telescopic

Product Overview

KITOZER high voltage AC voltage detector 10kV telescopic is a hand-held proximity and contact tester used by linemen to confirm absence of voltage before switching, grounding, or maintenance on overhead lines, switchgear bushings, and cable terminals. The detector emits audible beep and flashing red LED when the sensing tip approaches an energized conductor, and offers a self-test button to verify battery and circuitry before use. The telescopic fiberglass rod extends from 0.5m collapsed to 1.5m or 3m extended, keeping the operator at safe reach distance. The wrist strap prevents dropping, and the low-battery indicator prevents unexpected failure mid-job.

Technical Specifications

Rated voltage range: 0.4kV to 10kV AC. Detection method: capacitive proximity. Indication: buzzer 85 dB, red LED strobe. Self-test: built-in test oscillator. Rod: fiberglass epoxy, telescopic 4 sections. Collapsed length: 500mm. Extended length: 1500mm or 3000mm option. Insulation level of rod: 35kV. Power: 9V battery, 200 hours standby. Operating temperature: minus 20C to plus 55C. Ingress protection: IP54. Certifications: IEC 61243-3, CE. Brand: KITOZER. Warranty: 2 years. The detector also measures AC voltage presence on cables and busbars.

Application Scenarios

This detector is used by substation operators to verify dead state of 10kV feeders before grounding. Linemen use it on overhead distribution lines, transformer fuse cutouts, and cable terminations. It is also used in industrial plants to confirm de-energization of motor feeders, VFD outputs, and capacitor banks before maintenance. In data centers, it checks medium-voltage switchgear bus ducts. The detector is part of the mandatory lockout-tagout procedure per OSHA and local electrical safety codes. It is also useful for troubleshooting intermittent faults and tracing live cables in trays. It is standard PPE for any live-line electrical work under 10kV.

Advantages and Features

The capacitive method detects voltage without direct metal contact, reducing arc risk. The self-test function ensures the unit is alive before use, a critical safety feature. The telescopic fiberglass rod provides Class 35kV insulation, allowing safe reach to bushings and line terminals. The buzzer and strobe work simultaneously, so the operator receives feedback even in noisy or dark environments. KITOZER detectors are calibrated at the factory with traceable voltage source. The low-battery indicator prevents unexpected failure mid-job. Compared with non-contact pens, this unit has a longer rod and higher voltage range. The wrist strap prevents dropping. The compact carry case protects the rod during transport.

Installation and Maintenance Recommendations

Before each shift, press the self-test button; the buzzer and LED must activate. Test on a known live source to confirm sensing. Do not use the detector on circuits above 10kV. Keep the sensing tip clean and dry. Inspect the rod for cracks annually; replace if damaged. Store in the carry case with the rod collapsed. Replace the 9V battery annually even if unused. Calibrate the detector every 12 months at a certified lab. Do not expose to rain or heavy moisture; IP54 limits splash protection. If the unit fails self-test, remove from service immediately. KITOZER supplies calibration services and test leads.

Quality Assurance and Ordering Information

Each KITOZER detector is supplied with a calibration certificate traceable to national standards. Standard lead time is 5 days. KITOZER also supplies 35kV, 110kV, and 220kV detectors for higher voltage classes. The 3m extended rod is available for tall switchgear. Carrying case, wrist strap, and spare 9V battery are included. For export, KITOZER provides CE declaration. Samples can be shipped within 48 hours for site evaluation. KITOZER also supplies insulating gloves, hot sticks, and grounding rods as a complete live-line PPE package.

Technical Tips and Field Experience

From field experience, false voltage readings occur when the detector is near energized cables without actually touching the target. KITOZER recommends approaching the suspected dead conductor from a distance, and confirming zero reading before contact. Always test on a known live source first to prove the detector is working. In noisy substation environments, the buzzer may activate from stray electric field; use the contact mode tip for definitive verification. Keep the rod collapsed during transport to protect the fiberglass surface. KITOZER field engineers can provide live-line safety training for new linemen. Always pair the detector with insulating gloves and a hot stick for complete personal protection during live work. KITOZER also supplies a non-contact voltage pen for low-voltage troubleshooting as a complementary tool. KITOZER provides calibration services for all voltage detectors on site.

Price

From $45 per unit. Contact +86 13922289957 for 35kV and 110kV variants.