KITOZER Cold Aisle Containment Kit For 42U Server Cabinets

Product Overview

The KITOZER cold aisle containment kit converts a row of 42U server cabinets into a sealed cold aisle, preventing hot exhaust from recirculating to the front of the racks. The kit includes a rigid top canopy with polycarbonate panels, two end doors (hinged or sliding), magnetic brush strips along cabinet gaps, and a pressure relief baffle. By isolating the cold aisle, the data center can raise the cold aisle setpoint and reduce chiller energy while keeping server inlet temperatures within ASHRAE limits. The kit is designed for 600 mm or 800 mm wide cabinets and 1200 mm deep cabinets. The polycarbonate panels let light into the aisle and show equipment status without opening doors.

Technical Specifications

Compatible cabinet height 42U (2055 mm), cabinet widths 600 mm or 800 mm, cabinet depth up to 1200 mm. Canopy: 10 mm steel frame with 5 mm clear polycarbonate panels. End door: single hinged or double sliding, with magnetic strip seals. Brush strips: 50 mm wide, along cabinet-to-cabinet vertical gaps. Pressure relief baffle 600 x 600 mm. Operating temperature 10 to 40 degrees Celsius. Kit ships in flat packs. CE, RoHS. Warranty 5 years. Shipping weight 60 kg per bay.

Application Scenarios

Cold aisle containment is used in enterprise data centers, colocation halls, and high-density server rooms where rack density exceeds 5 kW per rack. It is also a retrofit for older rooms that suffer from hot spots. The kit supports both raised-floor and overhead duct cooling. It pairs with variable-speed CRAH units and hot aisle exhaust return for maximum energy efficiency. It is also used in GPU compute clusters, AI training rooms, and high-frequency trading floors where even short temperature excursions cause equipment throttling. The containment kit can be retrofitted to existing cabinets without replacing them, which reduces project cost and downtime.

Key Advantages

Containment eliminates hot air recirculation, allowing the cold aisle setpoint to rise from 18 to 24 degrees, cutting chiller energy by 20 to 40 percent. The polycarbonate canopy lets light into the aisle and shows equipment status. The magnetic brush strips seal cabinet gaps without tools. The pressure relief baffle prevents negative pressure when fans fail. The kit is modular and can be added row by row as capacity grows. The end doors are automatic closing, so staff do not forget to close them after entering the aisle. The polycarbonate canopy is UV-stabilized and does not yellow over time. The brush strips are removable for cleaning and replacement.

Installation and Maintenance Recommendations

Start by aligning the cabinet row into a straight line and bolting adjacent cabinets together. Mount the canopy frame on top of the cabinets, then add polycarbonate panels. Install end doors at both ends of the row. Seal vertical gaps with brush strips. Confirm no cable bundle leaks through the canopy. Monitor cold aisle pressure with a differential pressure gauge; target 5 to 10 Pa positive. Inspect seals annually and replace brush strips that become flattened. Keep end doors closed; use sliding doors for high-traffic aisles. The kit ships in flat packs on a wooden pallet. Spare polycarbonate panels and brush strips are stocked as service parts. The kit is available for both 600 mm and 800 mm wide cabinets, and for 42U and 47U heights. A hot aisle containment version is also available for installations where the hot aisle is returned to the CRAC units. The kit carries a 5-year warranty, and the factory provides a layout drawing and energy savings calculation for each project. The kit can be retrofitted without removing equipment from the racks. The installation typically takes a team of two technicians one day per row. The pressure relief baffle is calibrated at the factory and should not be adjusted on site. The kit is shipped in flat packs on a wooden pallet. The factory provides on-site installation supervision for large projects. The kit is available for both new installations and retrofits. A smoke detection sensor can be integrated into the containment canopy for early fire warning. The polycarbonate panels are 5 mm thick and UV-stabilized. The end doors are available as hinged or sliding, depending on aisle width. The magnetic brush strips seal vertical gaps between adjacent cabinets without tools. The pressure relief baffle prevents negative pressure inside the cold aisle when fans fail. The kit is modular and can be added row by row as capacity grows. The kit carries a 5-year warranty. The factory provides an energy savings calculation for each project. The kit can be retrofitted without removing equipment from the racks. The kit is backed by a 5-year warranty.

Price

From $1,800 per bay (canopy, doors, brushes). Contact +86 13922289957 for full-row pricing, hot aisle containment, and pressurization sensor kits.