The KITOZER 215kWh LFP battery cabinet is a high-density energy storage block for commercial and utility-scale projects. It houses 40 racks of LFP modules in a floor-standing outdoor or indoor cabinet, integrated with a master BMS, thermal management, gas detection, and aerosol suppression. The cabinet pairs with a 100kW or 125kW PCS to deliver a two-hour storage block, and can be paralleled to build 1MWh, 2MWh, or larger systems inside a 20-foot container.
Table of Contents
ToggleProduct Overview
KITOZER builds the 215kWh cabinet around a 614V nominal LFP cluster made of series-connected modules, each with its own slave BMS. The master BMS on the door performs cell balancing, state-of-charge estimation, and state-of-health modeling, and communicates with the PCS and the plant EMS over CAN and Modbus TCP. A dedicated thermal management unit keeps the battery band within a tight 25 to 35 degrees Celsius window, using an integrated heat-pump chiller that rejects heat through the cabinet side wall. The fire safety chain includes smoke and gas sensors, a manual and automatic aerosol nozzle, and a cable to the building fire panel for remote alarm.
Technical Specifications
Nominal energy 215kWh, nominal voltage 614V, usable energy 90 percent. Chemistry LFP, cycle life 8000 cycles to 80 percent DOD at 25 degrees Celsius. Continuous charge and discharge 100kW, peak 130kW for 30 seconds. Operating temperature charge 0 to 50, discharge minus 20 to 55. Thermal management: integrated heat pump, cooling capacity 3kW, heating 2kW. Protection IP54 outdoor, IP20 indoor option. Communication CAN, Modbus TCP, optional IEC 61850. Fire safety: smoke, gas, temp, aerosol suppression. Dimensions 1200 x 1000 x 2200 millimeters, weight 2200 kilograms. Certifications IEC 62619, UL 1973, UN 38.3, CE. KITOZER five-year warranty or 8000 cycles.
Application Scenarios
The 215kWh cabinet is the standard building block for 40-foot container storage plants rated 1MWh to 5MWh, and for walk-in outdoor storage rooms at factories and data centers. It is used for peak shaving, demand response, and solar self-consumption at medium industrial sites, and as a ride-through battery for small critical-load facilities. EPC integrators often ship four to six cabinets in one container together with a 500kW PCS, delivering a fully pre-tested storage skid to the site.
Key Advantages
The 614V nominal voltage matches the DC window of most commercial PCS, so integrators do not need a separate DC booster. Integrated heat-pump thermal management keeps the battery band tight, which directly translates into longer cycle life and a smaller spread between cell states of charge. The cabinet is fully wired and tested at the factory, so on-site commissioning is mostly about lifting, leveling, and connecting AC, DC, and communication. Up to ten cabinets can parallel on a common DC bus, allowing linear scaling from 215kWh to 2MWh per PCS group.
Installation and Maintenance
Set the cabinet on a level concrete pad with a 100 millimeter drainage gap underneath, and keep the exhaust side clear for at least 800 millimeters. Use shielded cables for the BMS communication trunk and ground the shield at the cabinet end. Commissioning requires verifying the BMS voltage window matches the PCS, running a capacity test at C/3, and testing the fire alarm relay to the building panel. Quarterly service includes cleaning the condenser filter, inspecting the aerosol nozzle pressure, and reviewing cell voltage spread from the EMS. Replace the thermal management air filter every six months in dusty environments.
Quality, Warranty and Delivery
Each 215kWh cabinet undergoes a full charge and discharge cycle at the factory, a thermal management run at 40 degrees Celsius ambient to confirm the heat pump holds the band, and a fire detection loop test with a simulated gas input. The cabinet ships at 30 percent state of charge on a heavy-duty steel skid, wrapped in a corrosion-inhibiting film, and includes a factory test report, a UN 38.3 summary, a set of spare fuses, and a spare air filter for the HVAC. For container projects, KITOZER pre-configures the BMS addresses and the Modbus point list so the integrator can drop the cabinet into the container without re-addressing. The five-year warranty covers the battery, BMS, HVAC, and fire detection, and the 8000-cycle life guarantee is tested at year five. KITOZER stocks spare modules and HVAC boards regionally, and offers a 48-hour on-site response package for utility-scale customers who face availability penalties.
Configuration and Ordering. KITOZER supplies each unit with the options specified at order placement, including the communication protocol, protection level, mounting orientation, and labeling language. Optional accessories such as external disconnect switches, surge protection kits, spare fuse sets, wall brackets, and remote monitoring gateways are available at a discount when ordered together with the main unit. The factory provides a final dimension and wiring drawing for customer approval before production starts, and the approved drawing becomes the manufacturing specification. Standard packaging is suitable for sea freight, and KITOZER can arrange air freight for urgent replacement orders on request. Every unit ships with a factory test report, a quick-start guide, and a bag of spare cable glands.
Price
From $28,800 per cabinet. Contact KITOZER for containerized 1MWh and 5MWh turnkey pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com