KITOZER UPS Bypass Cabinet: 120kVA Large Data Center

Product Overview

KITOZER 120kVA UPS bypass cabinet is engineered for large data center UPS systems where planned maintenance must not interrupt critical IT loads. The cabinet combines a motorized maintenance bypass switch, input and output air circuit breakers, harmonic-rated busbars, and a color HMI that shows the transfer sequence, source voltages, load currents, and breaker status. The motorized bypass allows both local button operation and remote transfer via Modbus TCP, supporting automated maintenance workflows triggered by the DCIM platform. The robust steel cabinet is designed for 24/7 operation in high-density server halls.

Technical Specifications

Rated power 120kVA, three phase 400V, rated output current 200A, input breaker 250A frame, output breaker 250A frame, motorized bypass switch with mechanical and electrical interlock, voltage 320V to 460V, frequency 47Hz to 53Hz. Color HMI 7 inch, Modbus TCP, SNMP option, Web HMI. Alarm relay outputs 8 channels. Forced air cooling with redundant fans. IP32 floor standing, dimensions 800mm wide by 1000mm deep by 2000mm high, weight 450kg. CE, IEC 60950, KITOZER brand, five year warranty.

Application Scenarios

This bypass cabinet is installed alongside 80kVA to 120kVA online double-conversion UPS systems in enterprise data centers, financial trading rooms, cloud colocation halls, and government computer rooms. It is also used in semiconductor fab support facilities and broadcast master control rooms where even a short interruption during UPS service is unacceptable. The motorized remote transfer feature is especially valuable in unmanned lights-out data centers, where maintenance staff may not be on site to physically operate the bypass switch during a scheduled UPS firmware update.

Advantages and Features

Motorized transfer removes the human error risk associated with manual rotary bypass switches, and the HMI guides the operator through each step with interlocked confirmation. The Modbus TCP and Web HMI integrate with DCIM for remote monitoring and scheduled transfer. Redundant cooling fans protect the busbar and breaker chambers from overheating. The cabinet supports parallel operation with multiple UPS bypass cabinets in modular UPS installations, allowing each UPS module to be serviced independently while the parallel bus stays energized. Event logging stores the last 1000 transfer operations for compliance and audit.

Installation and Maintenance

Mount the cabinet on a flat raised floor or concrete plinth, and route busbars or heavy cables between UPS, bypass cabinet, and output distribution. Verify phase sequence on both UPS and bypass sources before closing any breaker. Use the HMI guided-transfer wizard for the first operation. Maintenance includes quarterly fan filter cleaning, annual breaker trip test, and annual contact resistance check on the motorized switch. Keep firmware updated using the USB port on the HMI, and store spare contact kits on site for fastest replacement.

Price

From $8,980/pc. Contact +86 13922289957 for 120kVA bypass cabinet quote.