ToggleProduct Overview
The KITOZER 48-port Optical Distribution Frame is a 2U sliding-tray enclosure engineered for medium-density fiber termination in data centers, telecom exchanges, and enterprise main distribution frames. The sliding tray extends forward on ball-bearing rails, giving technicians full access to the rear of the adapter panel and the internal splice area without removing the unit from the rack. The front panel supports up to 48 SC simplex or 24 LC duplex adapters, configurable to project requirements.
This ODF is designed for installers who need to work on dense fiber links in crowded rack rows where rear access is limited. The ball-bearing slide rails support the full weight of loaded patch cords and extend 400mm forward, so technicians can stand in front of the rack and reach every splice point. A safety stop prevents the tray from sliding out completely during servicing.
Technical Specifications
Housing: 2U 19-inch rack mount, 1.5mm cold-rolled steel, black powder coat. Adapter panel: configurable SC simplex (48 cores) or LC duplex (48 fiber ends). Splice capacity: 48 cores across three slide-out splice trays. Fiber type: OS2 singlemode, OM3/OM4 optional. Insertion loss: less than 0.25dB, return loss greater than 50dB UPC. Cable entry: rear gland plate supports up to 6 round cables up to 20mm. Rail travel: 400mm ball-bearing slides. Operating temperature: -10C to +60C. Dimensions: 482mm x 350mm x 88mm. Includes: 48 pigtails, splice trays, protectors, cable ties, grounding kit. KITOZER, 3 year warranty.
The three splice trays are individually hinged and numbered, allowing one to be opened without disturbing fibers in adjacent trays. Each tray holds 16 splices in grooved channels. The rear gland plate uses compression glands that accept 6 cables of 10mm to 20mm diameter, supporting multiple backbone entries. The slide rails are rated for 30kg fully loaded, sufficient for the heaviest pigtail bundles.
Applications
This 48-port ODF is commonly deployed in data center main distribution areas, university campus fiber termination points, and telecom operator fiber cross-connect frames. It is also suitable for cable television headend fiber splitting and for enterprise MMR (Main Router) fiber uplinks to satellite wiring closets. The sliding tray makes it practical in cramped rack rows where rear access is limited.
In enterprise networks, the ODF terminates inter-building fiber backbones and distributes fibers to individual floor distribution frames. In co-location facilities, it serves as the demarcation point between carrier and customer fiber. The unit is also used in government and financial data centers where high port density and easy service access are both required.
Key Advantages
Ball-bearing sliding rails support smooth extension even when the chassis is fully loaded with patch cords. The modular adapter plate is field-replaceable, allowing a future conversion from SC to LC without replacing the whole enclosure. Internal radius guides protect fiber bend radius on both the splice side and the patch side. The split top cover lifts off for quick inspection. Port numbering is laser-etched on the front panel for durability. A built-in grounding lug bonds the chassis to the rack earth.
The 2U height balances port density with serviceability: denser 3U enclosures are harder to pull out fully, while shallower 1U units cannot hold 48 splices. The slide-out design means installers do not need to crawl behind the rack to add a splice. Every unit is factory tested for insertion loss and visual continuity before shipment.
Installation and Maintenance
Mount the outer chassis in the rack using front and rear brackets. Slide out the inner tray for splice work. Land incoming backbone cables on the rear anchor bar and route fibers into the splice trays. Fusion splice each fiber to a pigtail, then connect pigtail ends to the rear of the adapter panel. Label both ports and patch cords. After commissioning, perform an end-to-end insertion loss test with a light source and power meter, and record results in the as-built documentation.
Clean adapter end faces before mating. Keep dust caps on unused ports. Lubricate the slide rails every two years with a light machine oil. Re-tighten the rear gland nuts annually. During preventive maintenance, pull the tray out and inspect each splice tray for seated protectors and clean routing. Replace any pigtail that shows jacket damage or bend-radius violation.
Packaging and Compliance
The ODF ships in a reinforced corrugated carton with foam inserts. Accessories include a factory test report, installation manual, spare splice protectors, and a grounding wire. RoHS and CE compliant. APC polish, MPO adapters, and custom pigtail lengths are available for volume orders.
Price
From $265/pc. Contact +86 13922289957 for quotation and lead time.