KITOZER
KITOZER

KITOZER UPS Parallel Cabinet: 3 Units 100kVA Redundancy

Product Overview

KITOZER UPS parallel cabinet is a factory-assembled power distribution enclosure that allows up to three 100kVA UPS modules to be paralleled on a common output bus, delivering N plus 1 redundancy for medium data centers and critical industrial processes. The cabinet contains input breakers for each UPS, output breakers for each UPS, a common output busbar, a maintenance bypass path, and a synchronization and communication board that shares load-share signals between the parallel UPS units. The design removes the need for site-built parallel buswork and reduces commissioning time from days to hours. If one UPS module fails, the remaining units automatically absorb the load without interruption, and the failed module can be serviced while the others continue to feed the critical bus.

Technical Specifications

Total capacity 300kVA for three 100kVA modules, N+1 redundancy, three phase 400V, input breaker 160A per UPS, output breaker 160A per UPS, common output busbar rated 400A. Load-share cable ports for up to 3 UPS units, synchronization signal voltage isolated. Maintenance bypass 400A. LCD metering on each UPS branch. Modbus TCP, SNMP, Web HMI. IP32 cabinet, dimensions 1000mm wide by 1000mm deep by 2000mm high, weight 750kg. CE, IEC 60950, KITOZER brand, five year warranty.

Application Scenarios

This parallel cabinet is used in enterprise data centers, hospital IT departments, financial back offices, and industrial process control rooms that need redundant UPS capacity but do not want to invest in a single monolithic UPS. It is also popular in colocation projects where customers start with two 100kVA modules and later add a third as load grows. The cabinet supports hot-swap addition of UPS modules, so capacity can be expanded without powering down the critical bus. Typical loads include server racks, storage arrays, network switches, and precision air conditioning controls.

Advantages and Features

N+1 redundancy means the system survives the failure of any single UPS module without load dropout. Modular scaling allows capacity to grow with load, avoiding over-sizing at project start. The factory-wired busbar eliminates field bolted-bus errors, which are a common source of overheating in site-built parallel installations. Each UPS branch has its own breaker, so a fault in one module is isolated without dropping the others. The common maintenance bypass allows the entire parallel system to be serviced while the load runs on utility.

Installation and Maintenance

Position the parallel cabinet close to the UPS modules to keep load-share cables short, ideally under 3 meters. Route heavy busbars between cabinet output and the downstream distribution board. Set each UPS to the same parallel firmware version and the same output voltage and frequency. Use the commissioning wizard to confirm load-share balance across all modules. Maintenance includes annual busbar torque check, breaker trip test, and verification of load-share current balance. Keep the cabinet interior free of dust, and inspect cooling fans annually.

Price

From $12,800/pc. Contact +86 13922289957 for parallel cabinet pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart