KITOZER CDU: 20kW Coolant Distribution Unit For Edge Cabinet

Product Overview

The KITOZER 20kW Coolant Distribution Unit (CDU) is a compact, factory-tested thermal management platform engineered for edge computing cabinets, telecom roadside enclosures, and small AI inference nodes where air cooling can no longer keep up with rising chip power density. As single-socket server power climbs past 300W and accelerator cards exceed 500W, traditional fan-based cooling approaches require ever-larger airflow and ever-louder fans, which becomes impractical in quiet office-adjacent sites and outdoor cabinets. The CDU acts as the hydraulic and thermal bridge between the primary building loop and the secondary liquid loop that feeds rack-level cold plates or rear-door heat exchangers. Inside the cabinet, a redundant pump set, plate heat exchanger, expansion tank, make-up unit, and full sensor package are pre-piped and pre-wired, so the integrator only needs to connect site-side supply and return flanges and power. KITOZER ships the unit fully flushed, pressure-tested, and charged with glycol fill on request, cutting commissioning time from days to hours.

Technical Specifications

Cooling capacity 20 kW at rated delta T. Primary side connection DN32 flange, secondary side connection DN25 flange. Working pressure 1.0 MPa on both loops. Pump set two 100 percent redundant centrifugal pumps, N+1 configuration, each pump rated 2.5 m3/h at 18 m head, wet-end materials stainless steel 316. Plate heat exchanger stainless 316 plates with copper brazed construction, designed for 1.6 MPa burst pressure. Expansion tank 8 L bladder type, pre-charged to 1.5 bar. Sensors include supply and return temperature on both loops, differential pressure across pumps, conductivity, leak detection pads on drip tray, and a pressure transducer on the secondary loop. Controller touchscreen 5 inch color HMI, Modbus TCP and BACnet/IP communication, four dry contact alarms. Power supply 230 V single phase 50 Hz, rated consumption 0.6 kW including pumps and controls. Dimensions 600 x 600 x 1100 mm, weight 95 kg, IP20 protection. Coolant compatibility includes water-glycol up to 50 percent ethylene or propylene glycol, and dielectric fluids on request. Operating ambient range 5 to 40 C, storage temperature minus 20 to 60 C.

Application Scenarios

This 20 kW CDU targets edge cabinets housing 2 to 4 high-density servers, 5G core network nodes, retail edge inference, factory-floor vision computing, and remote telecom sites where outdoor ambient exceeds the comfort range of air-cooled rooms. It pairs naturally with rear-door heat exchangers delivering 15 to 25 kW per rack, or with a pair of cold-plate loops covering dual CPU and dual GPU workstations. The compact footprint also suits laboratories, medical imaging equipment, broadcast transmission cabinets, and railway signaling rooms that need liquid cooling but cannot allocate a mechanical room. It is equally at home in small cryptocurrency mining containers, oil and gas remote telemetry stations, and university research racks placed in existing lab space.

Advantages and Features

N+1 redundant pumps mean a single pump fault does not interrupt IT cooling. The modulating control valve on the primary loop allows free cooling when outdoor temperatures permit, reducing chiller runtime. Stainless 316 wetted parts resist corrosion from glycol water and extend service life beyond the five-year baseline warranty. The open-frame drip tray with leak sensor contains any small fitting seepage and triggers a remote alarm before water reaches equipment. Front-service layout lets technicians replace filters, pumps, and sensors without moving the CDU away from the wall. KITOZER also provides a factory pre-charge option with inhibited ethylene glycol at the user specified concentration. The HMI trends temperature, pressure, and pump current for seven days locally, enabling operators to spot fouling filters before they become a problem.

Installation and Maintenance

Site preparation requires a level floor capable of 150 kg load, two DN flanges on the primary loop, a dedicated 16 A power outlet, and a network drop for Modbus TCP. On mechanical completion, the commissioning engineer flushes the secondary loop to a target of 100 micron filter cleanliness, sets the pump differential pressure, and verifies leak alarms by actuating the test pads. Routine maintenance includes quarterly inspection of filter differential pressure, semi-annual glycol sample test for pH and inhibitor concentration, and annual visual check of pump seal condition. Spare filters and seal kits are stocked at the Guangzhou service center and shipped within 48 hours. KITOZER recommends keeping one spare cartridge and one spare pump mechanical seal on site for emergency response.

Price

From $4,880/unit. Contact +86 13922289957 for CDU quotation, drawing review, and factory lead time.