KITOZER Temperature Transmitter PT100 4-20mA Head Mount -50 to 200C

Product Overview

The KITOZER Temperature Transmitter PT100 4-20mA head-mount unit converts a PT100 resistance temperature detector signal into a calibrated two-wire 4 to 20 mA current loop for direct connection to PLC analog input cards, DCS systems, and temperature recorders. The transmitter fits inside a standard thermocouple head and accepts a three-wire PT100 sensor, compensating for lead resistance errors that otherwise plague long RTD runs. A rotary DIP switch on the PCB lets the user select the measurement range without configuration software, and the 0.1% accuracy supports process temperature control in food, pharmaceutical, HVAC, and industrial boiler applications. KITOZER calibrates every transmitter at three points against a traceable reference, and ships with a calibration certificate. The two-wire loop draws power from the 4 to 20 mA circuit itself, so no separate power supply is needed at the sensor head.

Technical Specifications

The transmitter accepts a PT100 three-wire RTD input, and optional PT1000, Ni100, or thermocouple K/J/E/T configurations are available on order. Standard range is -50 to +200 degrees Celsius, with other ranges from -200 to +800 degrees Celsius on request. Output is 4 to 20 mA two-wire loop, with 4 mA corresponding to lower range and 20 mA to upper range. Accuracy is plus or minus 0.1% of span plus or minus 0.1 degree Celsius, with temperature drift of 50 ppm per degree Celsius. Supply voltage is 12 to 36 V DC, and loop resistance is up to 500 Ohm at 24 V. Isolation between sensor and loop is 1500 V AC. Operating temperature is -40 to +85 degrees Celsius for the electronics, and the housing fits a standard DIN B thermocouple head. Protection rating is IP20 for the PCB, with the head providing IP54 when sealed.

Application Scenarios

Typical installations include HVAC duct and outdoor air temperature measurement, food processing ovens and chillers, pharmaceutical clean room monitoring, boiler feedwater and steam line temperature, tank temperature monitoring in chemical plants, and refrigeration system suction line temperature. In HVAC, the transmitter mounts in a duct immersion well and feeds a BMS analog input. In food ovens, multiple transmitters read zone temperatures for PID control. In clean rooms, the 4 to 20 mA signal integrates with monitoring systems that alarm on temperature excursions. In boiler lines, the head-mount unit survives high ambient near the pipe and sends a linear signal to the DCS. KITOZER also supplies the transmitter for retrofit projects where legacy temperature indicators need to be replaced with a 4 to 20 mA signal for SCADA integration.

Advantages and Features

The two-wire loop design is the primary advantage: one cable pair carries both power and signal, reducing wiring cost compared with three-wire RTD runs back to a central card. Lead resistance compensation removes the need for expensive compensated cable, and the 1500 V isolation prevents ground-loop errors between sensor head and control room. DIP switch range selection means the user configures the unit on the bench without a laptop, and the 0.1% accuracy supports tight process control. The head-mount form factor fits existing thermowells and heads, making retrofits simple. The transmitter supports sensor break detection: if the PT100 opens, the loop drives to 21 mA, a standard fault signal the PLC can alarm on. KITOZER backs the transmitter with a 3-year warranty and provides a traceable calibration certificate with each unit.

Installation and Maintenance Recommendations

Mount the transmitter inside a sealed thermocouple head on a thermowell immersed in the process. Use three-wire PT100 cable of equal length for all three wires, and keep the cable run away from VFD power cables. Tighten the head cable gland to IP54 and apply anti-corrosion grease in outdoor installations. Set the DIP switches to the required range before closing the head, and record the range in the calibration tag. During commissioning, read the 4 to 20 mA signal at the PLC and verify it matches a hand-held reference thermometer. For maintenance, inspect the head gasket annually, re-calibrate every two years against a reference, and keep a spare transmitter on site. When replacing the unit, note the DIP switch configuration so the new transmitter can be set up in minutes.

Quality Control and Certifications

Every KITOZER temperature transmitter is calibrated at three points against a traceable dry-block calibrator and reference RTD, and the calibration data is recorded on a certificate shipped with each unit. The factory performs 100% loop test, isolation test at 1500 V AC, and power reversal test. A sample from each lot undergoes EMC surge and burst testing per EN 61326-1. Production follows ISO 9001, and the transmitter is CE marked, with optional ATEX and IECEx intrinsic safety certification for hazardous areas. KITOZER stocks spare transmitters and sensor heads regionally, and the 3-year warranty covers calibration drift and manufacturing defects. Recalibration services are available on a return basis.