Table of Contents
ToggleProduct Overview
KITOZER 200A three-phase static transfer switch is engineered for medium data centers, industrial process plants, and commercial building switchboards that require dual-source power continuity without mechanical contact wear. The unit uses phase-controlled SCR stacks on each of the three phases, allowing independent transfer per phase so that a single-phase disturbance on one source does not force all three phases to drop. The controller continuously samples voltage, current, frequency, and phase angle, and it executes break-before-make transfer in less than four milliseconds whenever the preferred source leaves the programmable window. A built-in maintenance bypass switch allows technicians to isolate the STS while the load remains on utility, reducing planned downtime to nearly zero.
The per-phase independent transfer architecture is especially valuable in installations where one phase of the utility feed sags due to a large single-phase load starting nearby. Instead of transferring the entire 200A load, the STS restores only the affected phase from the alternate source, keeping the other two phases on the preferred supply. This minimizes the number of transfers and extends SCR life. The color LCD on the front door shows source and load values in real time, and the event log records every transfer with waveform snapshots for later analysis.
Technical Specifications
Rated current 200A, rated voltage 400V three phase four wire 50/60Hz, SCR transfer time below 4ms, per-phase independent transfer, voltage window programmable 320V to 460V, frequency window 47Hz to 53Hz, phase rotation protection, neutral transfer by contact. Front LCD displays source voltage, load current, frequency, active power, and event history. Communication ports include RS485 Modbus RTU, Ethernet Modbus TCP, optional SNMP and Web HMI. Alarm relay outputs 4 form C contacts rated 5A 250VAC. Forced air cooling with redundant fans, fan status monitored. Floor standing cabinet IP20, dimensions 600mm wide by 800mm deep by 2000mm high, weight 180kg. CE, IEC 60947, KITOZER brand, five year warranty.
Application Scenarios
This STS is typically installed upstream of UPS systems serving server halls of 20 to 60 racks, ahead of precision air conditioning units, and on the mains feed of semiconductor packaging lines, pharmaceutical clean rooms, and broadcast playout systems. It is also used in healthcare infrastructure where MRI scanners, CT machines, and laboratory analyzers must not reset during source changeover. The per-phase transfer feature is especially valuable when one phase on the preferred source sags while the other two remain healthy, because the controller can restore that single phase from the alternate source without disturbing the rest of the load. Integrators commonly pair this unit with a diesel generator and a second utility incomer to achieve tier-like redundancy.
Other applications include casino gaming floors, airport baggage handling systems, railway signaling power, and food processing lines with automated packaging. In each case, the cost of a single lost second of power far exceeds the cost of the STS. The unit is also suitable as the static transfer element within a modular UPS system, where it feeds the bypass source to the critical bus when the inverter is taken out of service. The Web HMI allows remote operators to see source health from the network operations center, and SNMP traps forward alarms to the existing NMS platform.
Advantages and Features
Semiconductor switching eliminates contact erosion, arcing, and the periodic contact replacement that mechanical ATS requires. The controller stores the last 500 events with timestamp and measured values, which is essential for incident analysis and compliance reporting. Redundant cooling fans keep SCR junction temperatures stable even at full load, and fan failure alarms trigger early replacement before thermal stress builds. The Web HMI allows remote monitoring from any browser, and the Modbus TCP integration feeds DCIM platforms with source status, load percentage, and transfer counts. A programmable priority cascade lets the engineer define which source is preferred and which conditions trigger a forced transfer, supporting complex generator-start sequences without external relays.
The maintenance bypass is interlocked so that the STS cannot be energized from both sources at once, protecting service personnel. The SCR stacks are rated for repeated transfer at full load, with no wear-out within the design life of the cabinet. The unit supports remote inhibit from the DCIM, allowing a controlled transfer during scheduled generator testing. The event log includes waveform snapshots at each transfer, giving engineers detailed data for power quality analysis. The redundant fans are hot-swappable, so a failing fan can be replaced while the STS remains in service.
Installation and Maintenance
Position the cabinet on a flat concrete floor, allow at least 800mm clearance at the front and 500mm at the rear for cabling and fan access. Incoming and outgoing cables enter through bottom gland plates. Verify that both sources share the same phase rotation before first energization, and use the phase-rotation test function on the controller. Torque busbar connections to the value listed on the cabinet drawing and recheck after the first month. Maintenance includes quarterly filter and fan inspection, annual busbar torque verification, and an annual full-load transfer test using the built-in test routine. Keep the cabinet door closed during operation to maintain IP20 protection and cooling airflow direction.
During commissioning, set the preferred source and the transfer inhibit logic according to the site operating procedure. If a generator is connected, program the generator-start output and the cool-down run-on timer. Use the Web HMI to confirm Modbus TCP connectivity to the DCIM server. Spare fans and a spare controller board should be kept on site to minimize downtime. The SCR stacks themselves have no scheduled replacement, but annual thermal imaging of the heatsinks is recommended to detect abnormal hot spots.
Price
From $7,980/pc. Contact +86 13922289957 for STS factory price and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com