Table of Contents
ToggleProduct Overview
The KITOZER 200 kW dry cooler is an outdoor air-to-water heat exchanger that rejects CDU secondary loop heat to ambient air without a cooling tower or chiller, whenever outdoor conditions allow. The coil is finned copper tube with aluminum fins, factory pressure-tested, and mounted on a galvanized steel cabinet with EC fan arrays for variable-speed control. The dry cooler accepts warm return water at 40 to 45 C from data center CDUs, enabling free cooling for most of the year in temperate and dry climates. A smart controller modulates fan speed based on return water temperature and outdoor ambient, minimizing energy use and frost risk in winter.
Technical Specifications
Rated capacity 200 kW at 35 C ambient, 40 C in and 35 C out water. Coil copper tube with 0.12 mm wall, aluminum louvered fins, 3 rows. Working pressure 1.6 MPa. Connections DN80 PN16 flange. Four EC fans 630 mm diameter, total motor power 4.0 kW, speed controlled 0 to 100%. Noise 68 dB(A) at 10 m. Controller Modbus TCP, BACnet, fan staging based on return water temperature. Cabinet galvanized steel with polyester powder coat, IP55. Operating ambient minus 30 to 50 C. Dimensions 3000 x 1600 x 2200 mm. Weight 780 kg. Winter operation with glycol protection to minus 20 C.
Application Scenarios
This dry cooler pairs with 150 to 250 kW data center CDU installations, immersion cooling tanks, and industrial process cooling loops that can operate at elevated water temperature. It is also used as a hybrid free-cooling pre-cooler ahead of an existing chiller, cutting chiller runtime in winter. Outdoor rooftop or ground-level installation is standard.
Advantages and Features
Dry cooler operation eliminates water consumption, water treatment, and Legionella risk associated with cooling towers. EC fans modulate to exact heat rejection, saving energy compared with fixed-speed fans. The coil is rated for 10 years of outdoor service with galvanized casing. The controller supports warm-water return strategy, which maximizes free-cooling hours. Flexible mounting supports horizontal, vertical, or rooftop installation.
Installation and Maintenance
Mount on a level concrete pad or steel frame, anchor with M16 bolts, connect DN80 flanges, and terminate power and control wiring. Slope the coil housing for rain drainage and provide a 1 m clearance around the unit for air intake. Inspect coils annually for dust and debris, clean with low-pressure water. Check fan motor bearings every two years. Test the modulating controller seasonally before summer peak. Drain or glycol-protect the loop before winter in freeze-prone locations.
Price
From $18,800/unit. Contact +86 13922289957 for dry cooler sizing and layout.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com