ToggleProduct Overview
KITOZER 96-loop power distribution monitor is a centralized metering and alarm device that continuously tracks current, voltage, power, and breaker status across up to 96 outgoing feeders inside a low-voltage switchboard or data center power cabinet. The main unit hosts a color touchscreen and a backplane of measurement and digital-input modules, and it communicates with the building management system or DCIM platform over Modbus TCP. By replacing dozens of individual panel meters with one centralized monitor, the system reduces panel depth, cabling, and maintenance cost while giving operators a single view of every circuit in the cabinet. The monitor supports both solid-core and split-core current transformers, which simplifies retrofit into live panels without removing existing busbars.
The plug-in module architecture means the monitor starts as a 12-channel base unit and grows to 96 channels as needed, simply by sliding in additional measurement modules. This protects the initial investment and matches the system to the actual feeder count of each cabinet. The touchscreen shows per-channel values, bar graphs, and trend curves, and it stores alarms and events with timestamps. Split-core current transformers clamp around existing cables without disconnecting them, which is essential in live panels where a shutdown window is not available.
Technical Specifications
Main unit 7 inch color touchscreen, up to 96 current measurement channels via plug-in CT modules, up to 96 digital input channels for breaker auxiliary contacts, three phase voltage measurement on main incomer, per-channel current range 1A to 600A depending on CT, accuracy class 0.5S. Active power, reactive power, power factor, kWh per channel. Modbus TCP, Modbus RTU, SNMP option. Alarm relay outputs 8 channels. Power supply 85V to 265VAC. Operating temperature minus 10C to plus 55C. DIN rail or panel mount. CE, KITOZER brand, three year warranty.
Application Scenarios
This monitor is installed in data center main switchboards, UPS output cabinets, busway tap-off boxes, and factory low-voltage distribution panels. It is also used in commercial building electrical rooms where energy cost allocation between tenants requires sub-metering on every feeder. The split-core CT option makes it suitable for retrofit projects where the panel is live and cannot be shut down for conventional solid-core CT installation. Facilities teams use the monitor to identify overloaded circuits, track energy use per department, and trigger alarms before a breaker trips.
Additional installations include hospital electrical rooms, university campus distribution boards, and shopping mall tenant panels. In each case, the operator needs granular per-feeder visibility without buying 96 standalone meters. The monitor is also used in industrial plants to track energy per production line, supporting cost accounting and energy efficiency programs. The Modbus TCP integration feeds the BMS or DCIM, giving facility managers a single dashboard for the whole electrical system.
Advantages and Features
Centralized metering replaces dozens of standalone meters, saving panel space and purchase cost. Plug-in modules allow channel count to grow from 12 to 96 without replacing the main unit. Split-core CTs reduce installation time in live panels. The touchscreen shows per-channel values, bar graphs, and historical trends, and the Modbus TCP gateway pushes data to BMS or DCIM. Alarm thresholds are programmable per channel, and event logs retain the last 1000 events with timestamp. The system also supports load-shedding logic, automatically reporting non-critical feeders when total load exceeds a configurable threshold.
The 0.5S accuracy class supports revenue-grade sub-metering, suitable for tenant billing. The digital inputs monitor breaker auxiliary contacts, so a tripped breaker raises an alarm immediately. The touchscreen offers password-protected user levels, supporting site access policies. The monitor stores one year of trend data onboard, allowing post-event analysis without a separate historian. The split-core CTs are available in several aperture sizes, suiting cables from small control wires to large busbars.
Installation and Maintenance
Mount the main unit on the panel door or on a DIN rail inside the cabinet. Install current transformers around each outgoing cable, keeping polarity correct, and route CT secondary wires to the plug-in modules. Wire digital inputs to breaker auxiliary contacts. Set the CT ratio, alarm thresholds, and Modbus address through the touchscreen. Commission each channel by comparing measured current against a clamp meter. Maintenance is limited to annual calibration verification and visual inspection of CT terminations. Firmware updates are available via USB port.
During installation, keep CT secondary wires short and twisted to minimize noise. Ground the CT secondary at one end per code. Label each channel on the touchscreen to match the as-built drawing. Set alarm thresholds at 80 percent of rated current for early warning. Wire the alarm relay outputs to the BMS and test each alarm. Keep spare plug-in modules on site. The touchscreen should be cleaned with a dry cloth, and the DIN rail mounting should be checked annually.