Table of Contents
ToggleProduct Overview
The KITOZER 30 kW liquid cooling cabinet is a fully enclosed, self-contained rack that combines compute space, cold plate distribution, an in-cabinet CDU, and a rear-door heat exchanger in one factory-tested unit. The 42U cabinet houses up to 8 GPU servers while the lower 12U contains the CDU module, pumps, and filtration. Warm server exhaust is captured by the rear-door water coil and returned to the CDU, so no hot air escapes into the room. The cabinet ships on casters for easy repositioning, and only two primary loop hoses, one power feed, and one network drop need to be connected on site. It is a turnkey answer for offices, labs, and co-lo cages that cannot build a dedicated data hall. Because the cabinet is self-contained, it can be rolled into an existing equipment room and operational within a day of delivery.
Technical Specifications
Cooling capacity 30 kW total, split 20 kW cold plate plus 10 kW rear door. Cabinet 600 x 1200 x 2000 mm, 42U usable, 12U CDU bay. Frame welded steel, powder coat, front and rear perforated doors. Rear-door heat exchanger aluminum coil with copper tubes, rated 10 kW at 10 K delta T. In-cabinet CDU two 0.55 kW pumps N+1, plate heat exchanger 30 kW, primary DN25, secondary DN20. Power distribution 3 phase 400 V, 32 A incomer, monitored PDU per rack unit. Sensors supply and return temperature, manifold pressure, leak mat, humidity inside cabinet. Controller 7 inch HMI, Modbus TCP, dry contact alarms. Ambient 5 to 40 C. Weight loaded 850 kg. Casters and leveling feet included. Sound pressure 55 dB(A) at 1 m.
Application Scenarios
Typical installations are AI inference appliances for corporate on-premise deployments, GPU workstations for design and VFX, edge AI cabinets at retail or factory sites, and research lab compute clusters. The cabinet also suits colocation cages where the operator wants to add high-density compute without requesting chilled water upgrades from the facility. Additional deployments include broadcast playout rooms, medical imaging compute, financial back-office servers, and university research racks placed in shared lab space.
Advantages and Features
Self-contained cabinet means no raised floor, no hot aisle containment, and no separate mechanical room. Rear-door coil handles the 20 percent of heat that cold plates miss, so room temperature stays stable. Monitored PDU integrates power and cooling telemetry into one dashboard. Casters allow the cabinet to be moved during office reconfiguration. Front and rear perforated doors can be locked for physical security. The integrated CDU means no additional mechanical footprint is required, which is valuable in space-constrained offices.
Installation and Maintenance
Position the cabinet on a level floor, level with the feet, lock casters, connect primary loop hoses, power, and network. Commissioning includes a 30 minute leak test, loop flush, and pump rotation check. Maintenance: quarterly filter inspection, semi-annual glycol sample, annual pump seal check. Spare filters and O-ring kits ship from the Guangzhou warehouse within 48 hours. KITOZER recommends keeping one spare pump cartridge and one filter on site for emergency response.
Packaging and Warranty
The cabinet ships on a steel shipping frame with foam corner protectors and a weatherproof cover. All glass, doors, and removable components are bagged separately. Factory run test covers pump rotation, leak test, control logic, and alarm simulation. KITOZER offers a 3 year warranty on the cabinet structure and 2 years on pumps and controls. Spare PDUs, fan trays, and control boards are stocked for 48 hour dispatch.
Price
From $14,800/cabinet empty, or $28,800 populated with 8 GPU server slots and cold plate kit. Contact +86 13922289957 for configuration.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com