KITOZER UPS Bypass Cabinet: 120kVA Large Data Center

Product Overview

KITOZER 120kVA UPS bypass cabinet is engineered for large data center UPS systems where planned maintenance must not interrupt critical IT loads. The cabinet combines a motorized maintenance bypass switch, input and output air circuit breakers, harmonic-rated busbars, and a color HMI that shows the transfer sequence, source voltages, load currents, and breaker status. The motorized bypass allows both local button operation and remote transfer via Modbus TCP, supporting automated maintenance workflows triggered by the DCIM platform. The robust steel cabinet is designed for 24/7 operation in high-density server halls.

The motorized switch eliminates the human-error risk associated with manual rotary bypass operations, because the HMI enforces a guided sequence and refuses out-of-order steps. Before transferring to bypass, the HMI checks that the bypass source voltage is within tolerance, that the UPS output is healthy, and that all interlocks are closed. Only then does it allow the next step. This guided approach is essential in large data centers where maintenance staff may be contractors who see the equipment only a few times per year.

Technical Specifications

Rated power 120kVA, three phase 400V, rated output current 200A, input breaker 250A frame, output breaker 250A frame, motorized bypass switch with mechanical and electrical interlock, voltage 320V to 460V, frequency 47Hz to 53Hz. Color HMI 7 inch, Modbus TCP, SNMP option, Web HMI. Alarm relay outputs 8 channels. Forced air cooling with redundant fans. IP32 floor standing, dimensions 800mm wide by 1000mm deep by 2000mm high, weight 450kg. CE, IEC 60950, KITOZER brand, five year warranty.

Application Scenarios

This bypass cabinet is installed alongside 80kVA to 120kVA online double-conversion UPS systems in enterprise data centers, financial trading rooms, cloud colocation halls, and government computer rooms. It is also used in semiconductor fab support facilities and broadcast master control rooms where even a short interruption during UPS service is unacceptable. The motorized remote transfer feature is especially valuable in unmanned lights-out data centers, where maintenance staff may not be on site to physically operate the bypass switch during a scheduled UPS firmware update.

The cabinet is also used in modular UPS installations where multiple bypass cabinets feed a common bus, allowing each UPS module to be serviced independently. In colocation facilities, the bypass cabinet is often owned by the facility operator while the UPS is owned by the tenant, so clear interlock and status signaling are essential for shared responsibility. The Web HMI gives remote NOC operators a clear view of bypass state, and the Modbus TCP integration feeds the DCIM with every transfer step.

Advantages and Features

Motorized transfer removes the human error risk associated with manual rotary bypass switches, and the HMI guides the operator through each step with interlocked confirmation. The Modbus TCP and Web HMI integrate with DCIM for remote monitoring and scheduled transfer. Redundant cooling fans protect the busbar and breaker chambers from overheating. The cabinet supports parallel operation with multiple UPS bypass cabinets in modular UPS installations, allowing each UPS module to be serviced independently while the parallel bus stays energized. Event logging stores the last 1000 transfer operations for compliance and audit.

The HMI offers password-protected user levels, so that only authorized engineers can initiate a transfer. The interlocks prevent the bypass and UPS output from being closed together, even in software. The busbar is sized with 125 percent continuous rating, providing margin for inrush and future load growth. The redundant fans are hot-swappable. The cabinet supports remote EPO and remote inhibit, fitting into the existing site safety logic. The five year warranty reflects the robust design.

Installation and Maintenance

Mount the cabinet on a flat raised floor or concrete plinth, and route busbars or heavy cables between UPS, bypass cabinet, and output distribution. Verify phase sequence on both UPS and bypass sources before closing any breaker. Use the HMI guided-transfer wizard for the first operation. Maintenance includes quarterly fan filter cleaning, annual breaker trip test, and annual contact resistance check on the motorized switch. Keep firmware updated using the USB port on the HMI, and store spare contact kits on site for fastest replacement.

During commissioning, test the guided transfer sequence with a dummy load before connecting critical IT. Verify that the HMI alarms correctly when the bypass source is out of tolerance. Set up user accounts and passwords according to the site access policy. Wire the remote EPO and inhibit contacts and test them. Spare fans, spare control board, and spare contact kits should be stocked locally. Annual thermal imaging of the busbar joints is recommended to detect loose connections early. The cabinet is delivered with a factory test report covering breaker operation, interlock check, and HMI communication, which supports site acceptance testing without additional measurement.