KITOZER Battery Internal Resistance Tester: 48 Channels

Product Overview

KITOZER 48-channel battery internal resistance tester goes beyond simple voltage monitoring by measuring the internal resistance of each battery cell online, which is the most reliable indicator of VRLA battery health. The unit injects a low-amplitude AC test signal onto the charging string and measures the voltage response, computing internal resistance without disconnecting the battery. Rising internal resistance is the early warning of dry-out, grid corrosion, or soft short, typically appearing months before a visible voltage drop. The tester logs resistance trends per cell and alarms on abnormal values, supporting predictive battery replacement planning in UPS and substation DC systems.

Open-circuit voltage alone often looks normal even on a degraded cell, because the cell can still hold a voltage under no load but collapses under discharge. Internal resistance, by contrast, rises steadily as the cell ages, giving a months- or years-long warning trend. The KITOZER tester measures resistance while the battery remains on float charge, so no outage window is needed. Trend data lets engineers compare each cell against its baseline and against its neighbors, identifying outliers before they fail.

Technical Specifications

48 cell channels, internal resistance measurement range 0.000mOhm to 3000mOhm, accuracy plus or minus 0.5 percent. Cell voltage range 0V to 3V, accuracy plus or minus 5mV. Temperature per channel optional up to 12 probes. String current via hall sensor. Main unit 7 inch color touchscreen. RS485 Modbus RTU, Ethernet Modbus TCP, Web HMI. Alarm relay outputs 8. Internal memory 1GB for one year of trends. Power supply 85V to 265VAC. Operating temperature 0C to plus 50C. CE, KITOZER brand, three year warranty.

Application Scenarios

This tester is used in large data center battery rooms with hundreds of VRLA cells, in utility substation DC systems, and in industrial UPS systems where battery failure during a power outage is unacceptable. It is also deployed in solar power plants and telecom central offices with long battery strings. The 48-channel unit covers a full 110V or 220V substation battery string in one device, and multiple units can be cascaded for larger UPS banks. Trend data supports capital planning by identifying which cells are approaching end of life before the next outage test.

Additional installations include hospital UPS rooms, offshore oil platform control power, and railway signaling batteries. In each case, the battery plant is large enough that manual resistance testing with a handheld unit would take days. The online tester automates the process, taking a full string reading in minutes and storing it for trend comparison. The Web HMI gives facility managers remote access to cell health data, and alarm emails flag weak cells before they affect the string.

Advantages and Features

Internal resistance is a far more sensitive health indicator than open-circuit voltage, which often looks normal until the cell is fully degraded. Online testing means the battery string stays on float charge during measurement, so no outage window is needed. Trend logging with Web HMI lets engineers compare resistance values across quarters and years. Alarm thresholds are programmable per cell, so a single weak cell triggers early warning without alarming the whole string. The tester also records conductance and voltage at the same time, supporting correlation analysis during failure investigation.

The 0.5 percent accuracy allows detection of small resistance changes that signal early aging. The Web HMI offers real-time cell bar graphs and historical trend curves. The 1GB internal memory stores one year of data, supporting long-term health trending. The alarm relay outputs trigger local annunciation and BMS alarms. The unit supports up to 32 testers on one Ethernet network, covering very large battery plants.

Installation and Maintenance

Mount the main unit in the battery room cabinet and run sense leads to each cell terminal. Use shielded twisted pair for resistance sense leads to avoid noise. Install the hall current sensor around the main battery cable. Set cell type, nominal voltage, and alarm thresholds through the touchscreen. Baseline the resistance values during commissioning and use those values as the reference for future trend comparisons. Maintenance includes annual sense-cable resistance check and calibration verification. Clean terminals if corrosion appears.

During installation, keep sense leads away from charging cables to avoid measurement noise. Ground the shield at one end. Set the resistance alarm threshold at 1.2 times the baseline value for early warning. Test the alarms by temporarily increasing the threshold. The battery room should be kept at 20C to 25C, because temperature accelerates aging. Annual capacity discharge tests should be scheduled for cells whose resistance trend is rising fastest. The Web HMI can be accessed from the local network, and Modbus TCP points can be mapped into the DCIM for unified battery health monitoring alongside UPS and environmental data.