KITOZER Analog Output Module 8CH 14-bit 0-10V 4-20mA Isolated

Product Overview

The KITOZER Analog Output Module 8CH 14-bit drives control valves, VFD speed references, I/P transducers, and chart recorders from a PLC or distributed IO system. Eight channels are software-configurable for 0 to 10 V voltage output or 4 to 20 mA current output, so a single module covers both analog control signal types across a machine. Each channel is isolated to 2500 V AC from the backplane, protecting the controller from field surges and ground loops introduced by long analog wiring. The 14-bit resolution and 0.1% accuracy support smooth PID control of temperature, pressure, and flow loops without jitter or step changes. KITOZER adds a fail-safe state on power loss: each channel can be configured to drive to 0 V, 0 mA, hold last value, or a predefined safe value, preventing actuator runaway during supply interruption. Every module is factory-calibrated and includes a traceable calibration certificate.

Technical Specifications

The module operates from 24 V DC at 150 mA plus loop current. Eight channels each support 0 to 10 V voltage output with 1 kOhm minimum load, and 4 to 20 mA current output with 750 Ohm maximum load. Resolution is 14 bits, accuracy is plus or minus 0.1% of full scale at 25 degrees Celsius, and settling time is 100 microseconds to within 0.1%. Channel-to-channel isolation is 2500 V AC, and backplane-to-field isolation is 2500 V AC. Each channel has short-circuit protection and overtemperature shutdown. On power loss, the fail-safe state is configurable per channel as 0 V, 0 mA, hold, or safe value. Operating temperature is -20 to +60 degrees Celsius, humidity 5 to 95% non-condensing, and the housing is 35 mm wide for DIN rail mounting. The module weighs 220 g and is CE, UL, and RCM certified.

Application Scenarios

The analog output module is deployed in HVAC systems driving damper actuators and VAV boxes, water treatment plants modulating control valves and VFD pump speed, chemical batching stations driving I/P transducers on pneumatic valves, oven control panels modulating SSR power controllers via 0 to 10 V signal, and test benches driving servo valve current references. In HVAC, each channel drives a damper actuator to hold duct pressure at setpoint. In water treatment, 4 to 20 mA signals set VFD speed on booster pumps based on pressure transmitter feedback. In batching, channels open and close pneumatic valves via I/P transducers in proportion to PID output. KITOZER also supplies the module for DCS retrofit projects where legacy analog outputs need to be replaced without changing the field wiring.

Advantages and Features

Mixed voltage and current output in one module simplifies spares and engineering, because the same part number can drive a damper actuator and a VFD. Per-channel isolation prevents a short on one channel from affecting others, and the fail-safe state on power loss is a critical safety feature for pressure and flow control loops. 14-bit resolution gives smooth analog control without visible stepping on valve or VFD response. The module auto-detects on the KITOZER backplane and presents each channel as a PLC tag, so engineers write PID output directly to the tag. Diagnostics include per-channel over-range, short-circuit, and overtemperature flags visible in the PLC. KITOZER backs the module with a 5-year warranty and provides pre-sale configuration support to ensure each channel is set for the correct load type.

Installation and Maintenance Recommendations

Mount the module on the DIN rail away from VFD output cables and contactors. Use shielded twisted pair cable for analog wiring, and ground the shield at the cabinet earth bar only at one end. For 4 to 20 mA loops, verify the loop load does not exceed 750 Ohm, including wire resistance. For 0 to 10 V drives, keep cable runs under 30 m to avoid voltage drop into high-impedance loads. During commissioning, use the PLC force function to drive each channel to 0, 50, and 100% and verify the field actuator responds. Configure the fail-safe state for each channel according to the machine safety case. For maintenance, inspect terminals annually, measure output voltage or current with a calibrated multimeter every two years, and keep a spare module on site. When replacing a module, record the channel configuration and fail-safe state in the project file to speed recommissioning.

Quality Control and Certifications

Every KITOZER analog output module is calibrated at zero, mid, and full scale on an automated bench, and the calibration coefficients are stored in flash for traceability. The factory tests each channel for short-circuit protection, over-temperature shutdown, and fail-safe state at power loss, and performs 2500 V AC isolation testing. A sample from each lot undergoes EMC burst and surge testing. Production follows ISO 9001, and the module is CE marked to EN 61131-2 and EN 61326-1, with UL and RCM certification. KITOZER ships each module with a calibration certificate, and stocks spares regionally. The 5-year warranty covers manufacturing defects and includes free firmware updates for the product lifetime.