KITOZER Differential Pressure Transmitter 0-10 kPa Filter DP

Product Overview

The KITOZER Differential Pressure Transmitter 0-10 kPa measures the pressure drop across filters, strainers, orifice plates, and ventilation ducts in HVAC and process systems. The two pressure ports connect to the upstream and downstream sides of the element, and the transmitter outputs a calibrated 4 to 20 mA signal proportional to the difference. The low 0 to 10 kPa range suits clean room filter monitoring, baghouse differential pressure, and chilled water filter DP, where gauge pressure transmitters would be too coarse. The dual stainless diaphragms isolate the sensing element from overpressure on either side, and the IP65 housing supports outdoor and duct mounting. KITOZER builds the unit with a silicon piezoresistive sensor and offers optional field-selectable range and an LCD display. Every DP transmitter is calibrated at zero and span against a digital manometer traceable to national standards.

Technical Specifications

Measuring range is 0 to 10 kPa differential, with optional ranges from 0 to 0.1 kPa up to 0 to 7 MPa on request. Output is 4 to 20 mA two-wire, and optional Modbus RTU or 0 to 10 V output is available. Accuracy is plus or minus 0.5% full scale at 25 degrees Celsius, with long-term stability of 0.2% per year. Overpressure on either port is 10 times full scale without damage. Supply voltage is 9 to 32 V DC, and loop resistance is up to 500 Ohm at 24 V. Wetted parts are 316L stainless, and pressure ports are G1/4 female. Isolation between ports is 7 MPa. Operating temperature is -20 to +85 degrees Celsius for the electronics, and the housing is IP65. The unit is CE and UL certified, with optional intrinsic safety for hazardous areas.

Application Scenarios

Primary applications include HVAC HEPA and MERV filter monitoring in clean rooms and commercial buildings, baghouse filter DP in dust collection systems, orifice plate flow measurement in water and gas lines, chilled water strainer DP in HVAC plants, and blood and pharmaceutical filter DP monitoring. In clean rooms, the transmitter alarms when HEPA resistance rises, signaling filter replacement. In baghouses, DP triggers cleaning solenoids and filter change-out. In orifice plate flow, the DP signal feeds a square-root extractor in the PLC to compute flow. In water plants, it monitors strainer blockage and triggers backwash. KITOZER also supplies the DP transmitter for leak detection on heat exchangers and for static pressure monitoring in ductwork to control VFD fan speed.

Advantages and Features

Low-range measurement down to 0.1 kPa is the key advantage, allowing DP monitoring of clean filters and HEPA elements that gauge transmitters cannot resolve. The 10x overpressure rating on either port protects against single-side pressure during valve operation or filter bypass. 316L wetted parts handle air, water, oil, and mild chemicals. The 4 to 20 mA loop integrates with any PLC analog input, and optional Modbus RTU supports digital monitoring. The compact housing mounts directly on a duct or panel, and the optional LCD shows live DP at the point of installation. KITOZER offers a 3-year warranty and a traceable calibration certificate, and can supply intrinsically safe versions for Zone 1 and Zone 2 hazardous areas.

Installation and Maintenance Recommendations

Mount the DP transmitter level and connect the high port to upstream and low port to downstream. Use impulse tubing with a slight slope toward the process for liquid service, and avoid trapped loops. For gas service, mount the transmitter above the taps so condensate drains away. Isolate both ports with ball valves and install a three-valve manifold for safe zeroing. Purge the impulse lines during commissioning to remove air or debris. Verify zero with both ports vented, and check span with a hand pump. For maintenance, inspect impulse lines for blockage annually, re-calibrate every two years, and keep a spare on site. In dusty applications, install purge taps on the impulse lines to blow out collected dust without removing the transmitter.

Quality Control and Certifications

Every KITOZER differential pressure transmitter is calibrated at zero and span against a traceable digital manometer, and the certificate ships with the unit. The factory performs 100% overpressure test on both ports at 10 times range, isolation test at 1500 V AC, and IP65 sealing check. A sample from each lot undergoes EMC burst, surge, and vibration testing. Production follows ISO 9001, and the transmitter is CE marked, with optional ATEX intrinsic safety certification for Zone 1 and Zone 2. KITOZER stocks spare DP transmitters and three-valve manifolds regionally, and the 3-year warranty covers drift and manufacturing defects. Recalibration service is available on a return basis. Custom ranges and flanged process connections are offered on request. Stainless steel diaphragm seals for corrosive fluids are also available.