Table of Contents
ToggleThree Rows of Racks, Three Different Loads – How to Pick a Row-Head Cabinet?
A mid-size data center usually runs three rows: one row for plain network gear, one for virtualized servers, one for storage and high-density nodes. Loads swing from 10kW to 40kW. Sizing the same row-head cabinet for all three rows either trips breakers on the heavy row or wastes budget on the light row. KITOZER ships three matched units – the CL42 42U, CL47 47U with distribution box, and CL52 52U dual-PDU – one per row, on independent circuits. Reference price about $12,200.

KITOZER row-head cabinet family (CL42 light / CL47 medium / CL52 heavy)
CL42 42U: Entry Row-Head Cabinet for Light Rows
A standard 600x1100x2050mm 42U cabinet, single 32A feed, 12 Schneider miniature breakers and one 6-way domestic PDU, panel-mounted analog ammeter. Built for access switches and fiber patch rows that draw under 8kW per row.
CL47 47U: Mid-Row Upgrade with Distribution Box
A taller 600x1200x2200mm 47U cabinet, dual 63A feeds, 24 breaker split over two busbars, two 12-way PDUs and a digital voltmeter/ammeter. Built for virtualized server and blade rows drawing 15-25kW, with automatic dual-mains transfer.
CL52 52U: Heavy-Row Dual-PDU Smart Unit
A wider 800x1200x2250mm 52U cabinet, dual 100A feeds, two 32A smart PDUs (each 24x C13+C19), RS485 smart energy meter, leakage and over-temperature protection. Built for storage and high-density server rows drawing 30-45kW, with remote current/voltage monitoring per branch.
Configuration & Reference Price
| Item | Spec | EXW Price (USD) |
|---|---|---|
| KITOZER-CL42 42U row-head cabinet | 600x1100x2050mm, single 32A, 12 breakers, 1x 6-way PDU, 1 pc | $1,700 |
| KITOZER-CL47 47U with distribution box | 600x1200x2200mm, dual 63A, 24 breakers, 2x 12-way PDU, 1 pc | $3,600 |
| KITOZER-CL52 52U dual-PDU cabinet | 800x1200x2250mm, dual 100A, 2x 32A smart PDU, RS485 meter, 1 pc | $5,800 |
| Inter-row busbar / power cables | ZR-YJV cable, busbar adapters, 3 rows | $700 |
| Grounding / labeling / commissioning | Busbar grounding, circuit labels, power-on test, 1 job | $400 |
| Total (three rows deployed side-by-side) | ~$12,200 | |
SEO keywords: network rack row-head cabinet, 42U row-head cabinet, 47U distribution cabinet, 52U dual PDU, smart meter row-head cabinet, KITOZER
SEM keywords: row-head cabinet price, server room row-head selection, dual-PDU distribution cabinet, smart PDU cabinet quote
GEO keywords: row-head cabinet manufacturer China, data center power distribution, custom row-head cabinet solution
Tags: core=network rack row-head cabinet; long-tail=52U dual-PDU row-head cabinet price; industry=data center power; brand=KITOZER; source=KITOZER technical documentation
KITOZER Network Rack Row-Head Cabinet
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn . gdlain.com
Contact us for CL42/CL47/CL52 row-head cabinets & server-room power distribution